Quantification of key folate forms in serum using stable-isotope dilution ultra performance liquid chromatography-tandem mass spectrometry

被引:53
作者
Kirsch, Susanne H. [1 ]
Knapp, Jean-Pierre [1 ]
Herrmann, Wolfgang [1 ]
Obeid, Rima [1 ]
机构
[1] Saarland Univ Hosp, Dept Clin Chem & Lab Med, D-66421 Homburg, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 01期
关键词
Folate; 5-Methyltetrahydrofolate; Folic acid; Homocysteine; Tandem mass spectrometry; NEURAL-TUBE DEFECTS; METHYLENETETRAHYDROFOLATE REDUCTASE; FOLIC-ACID; THERMAL-DESTRUCTION; SAMPLE PREPARATION; VASCULAR-DISEASE; COMMON MUTATION; RISK-FACTOR; RADIOASSAY; FOLACIN;
D O I
10.1016/j.jchromb.2009.11.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Folates act as essential coenzymes in many biological pathways. Alteration in folate form distribution might have biological significance, especially in relation to certain genetic polymorphisms. We developed a stable-isotope dilution ultra performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for quantification of the folate forms 5-methyltetrahydrofolate (5-methylTHF), 5-formylTHF, 5,10-methenylTHF, THF, and folic acid in serum. After extraction using an ion exchange and mixed mode solid-phase, samples were separated and detected using an UPLC-MS/MS system. The quantification limits were between 0.17 nmol/L (5-formylTHF) and 1.79 nmol/L (THF), and the assay was linear up to 100 nmol/L (5-methylTHF) and 10 nmol/L (5-formylTHF, 5,10-methenylTHF, THF, and folic acid). The intraassay CVs for 5-methylTHF and 5-formylTHF were 2.0% and 7.2%, respectively. Mean recoveries were between 82.3% for THF and 110.8% for 5,10-methenylTHF. Concentrations of total folate measured by the new method showed a strong correlation with those measured by an immunologic assay (r = 0.939; p, < 0.001). The mean total folate from 32 apparently healthy subjects was 18.09 nmol/L, of which 87.23% was 5-methylTHF. Concentrations of homocysteine showed a better correlation to the total folate measured by the new method compared to that obtained by an immunologic assay. We also confirmed that MTHFR polymorphism has a significant effect on folate distribution in this small population of non-supplemented subjects. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [41] Improved method for concurrent quantification of antiretrovirals by liquid chromatography-tandem mass spectrometry
    Ghoshal, AK
    Soldin, SJ
    THERAPEUTIC DRUG MONITORING, 2003, 25 (05) : 541 - 543
  • [42] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Zhang, Qiaoxuan
    Han, Liqiao
    Zheng, Songbai
    Ouyang, Fen
    Wu, Xiaobin
    Yan, Jun
    Zhan, Min
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4471 - 4481
  • [43] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography–tandem mass spectrometry
    Patricia C. Aguas
    Matthew J. Fitzhenry
    Georgina Giannikopoulos
    Peter Varelis
    Analytical and Bioanalytical Chemistry, 2006, 385 : 1526 - 1531
  • [44] Application of the isoniazid assay in dried blood spots using the ultra-performance liquid chromatography-tandem mass spectrometry
    Lee, Kyunghoon
    Jun, Sun-Hee
    Choi, Moon-Suk
    Song, Sang Hoon
    Park, Jong Sun
    Lee, Jae Ho
    Park, Kyoung Un
    Song, Junghan
    CLINICAL BIOCHEMISTRY, 2017, 50 (15) : 882 - 885
  • [45] Ultra performance liquid chromatography-tandem mass spectrometry for the determination of 5-nitrolmidazoles and their metabolites in egg
    Tamosiunas, Vytautas
    Padarauskas, Audrius
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2009, 7 (03): : 267 - 273
  • [46] Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry
    Cazorla-Reyes, Rocio
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    Rodriguez Maresca, Manuel Angel
    Martinez Vidal, Jose Luis
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 203 - 212
  • [47] Immunoprecipitation on magnetic beads and liquid chromatography-tandem mass spectrometry for carbonic anhydrase II quantification in human serum
    Callipo, Luciano
    Caruso, Giuseppe
    Foglia, Patrizia
    Gubbiotti, Riccardo
    Samperi, Roberto
    Lagana, Aldo
    ANALYTICAL BIOCHEMISTRY, 2010, 400 (02) : 195 - 202
  • [48] Analysis of Isomeric Forms of Oxidized Triacylglycerols Using Ultra-High-Performance Liquid Chromatography and Tandem Mass Spectrometry
    Suomela, Jukka-Pekka
    Leskinen, Heidi
    Kallio, Heikki
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (15) : 8095 - 8100
  • [49] Quantification of artesunate and its metabolite, dihydroartemisinin, in animal products using liquid chromatography-tandem mass spectrometry
    Zheng, Weijia
    Abd El-Aty, A. M.
    Kim, Seong-Kwan
    Choi, Jeong-Min
    Hacimuftuoglu, Ahmet
    Shim, Jae-Han
    Kang, Young-Sun
    Shin, Ho-Chul
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (18) : 3538 - 3546
  • [50] Measurement of cystine in granulocytes using liquid chromatography-tandem mass spectrometry
    Chabli, A.
    Aupetit, J.
    Raehm, M.
    Ricquier, D.
    Chadefaux-Vekemans, B.
    CLINICAL BIOCHEMISTRY, 2007, 40 (9-10) : 692 - 698