Quantification of key folate forms in serum using stable-isotope dilution ultra performance liquid chromatography-tandem mass spectrometry

被引:53
|
作者
Kirsch, Susanne H. [1 ]
Knapp, Jean-Pierre [1 ]
Herrmann, Wolfgang [1 ]
Obeid, Rima [1 ]
机构
[1] Saarland Univ Hosp, Dept Clin Chem & Lab Med, D-66421 Homburg, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 01期
关键词
Folate; 5-Methyltetrahydrofolate; Folic acid; Homocysteine; Tandem mass spectrometry; NEURAL-TUBE DEFECTS; METHYLENETETRAHYDROFOLATE REDUCTASE; FOLIC-ACID; THERMAL-DESTRUCTION; SAMPLE PREPARATION; VASCULAR-DISEASE; COMMON MUTATION; RISK-FACTOR; RADIOASSAY; FOLACIN;
D O I
10.1016/j.jchromb.2009.11.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Folates act as essential coenzymes in many biological pathways. Alteration in folate form distribution might have biological significance, especially in relation to certain genetic polymorphisms. We developed a stable-isotope dilution ultra performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for quantification of the folate forms 5-methyltetrahydrofolate (5-methylTHF), 5-formylTHF, 5,10-methenylTHF, THF, and folic acid in serum. After extraction using an ion exchange and mixed mode solid-phase, samples were separated and detected using an UPLC-MS/MS system. The quantification limits were between 0.17 nmol/L (5-formylTHF) and 1.79 nmol/L (THF), and the assay was linear up to 100 nmol/L (5-methylTHF) and 10 nmol/L (5-formylTHF, 5,10-methenylTHF, THF, and folic acid). The intraassay CVs for 5-methylTHF and 5-formylTHF were 2.0% and 7.2%, respectively. Mean recoveries were between 82.3% for THF and 110.8% for 5,10-methenylTHF. Concentrations of total folate measured by the new method showed a strong correlation with those measured by an immunologic assay (r = 0.939; p, < 0.001). The mean total folate from 32 apparently healthy subjects was 18.09 nmol/L, of which 87.23% was 5-methylTHF. Concentrations of homocysteine showed a better correlation to the total folate measured by the new method compared to that obtained by an immunologic assay. We also confirmed that MTHFR polymorphism has a significant effect on folate distribution in this small population of non-supplemented subjects. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [1] Quantification of acetylcholine, choline, betaine, and dimethylglycine in human plasma and urine using stable-isotope dilution ultra performance liquid chromatography-tandem mass spectrometry
    Kirsch, Susanne H.
    Herrmann, Wolfgang
    Rabagny, Yannick
    Obeid, Rima
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (32): : 3338 - 3344
  • [2] Quantification of Folic Acid in Human Serum Using Isotope Dilution Ultra-High-Pressure Liquid Chromatography/Mass Spectrometry
    Hyung, Seok-Won
    Lee, Joonhee
    Seo, Hye-Young
    Kim, Byungjoo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2018, 39 (01): : 105 - 110
  • [3] Quantification of urinary folate catabolites using liquid chromatography-tandem mass spectrometry
    Niesser, Mareile
    Harder, Ulrike
    Koletzko, Berthold
    Peissner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 : 116 - 124
  • [4] Quantification of folate metabolites in serum using ultraperformance liquid chromatography tandem mass spectrometry
    Wang, Xiuwei
    Zhang, Ting
    Zhao, Xin
    Guan, Zhen
    Wang, Zhen
    Zhu, Zhiqiang
    Xie, Qiu
    Wang, Jianhua
    Niu, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 962 : 9 - 13
  • [5] A novel, quantitative assay for homocarnosine in cerebrospinal fluid using stable-isotope dilution liquid chromatography-tandem mass spectrometry
    Jansen, EEW
    Gibson, KM
    Shigematsu, Y
    Jakobs, C
    Verhoeven, NA
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 196 - 200
  • [6] Assay of whole blood (6S)-5-CH3-H4folate using ultra performance liquid chromatography tandem mass spectrometry
    Kirsch, Susanne H.
    Herrmann, Wolfgang
    Geisel, Juergen
    Obeid, Rima
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 895 - 902
  • [7] Quantification of intracellular homocysteine by stable isotope dilution liquid chromatography/tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhi-Yong
    Brown, Karen S.
    Whitehead, Alexander S.
    Blair, Ian A.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) : 107 - 112
  • [8] Simultaneous quantification of S-adenosyl methionine and S-adenosyl homocysteine in human plasma by stable-isotope dilution ultra performance liquid chromatography tandem mass spectrometry
    Kirsch, Susanne H.
    Knapp, Jean-Pierre
    Geisel, Juergen
    Herrmann, Wolfgang
    Obeid, Rima
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3865 - 3870
  • [9] Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum
    Hannisdal, Rita
    Ueland, Per Magne
    Svardal, Asbjorn
    CLINICAL CHEMISTRY, 2009, 55 (06) : 1147 - 1154
  • [10] Quantitative analysis of tissue folate using ultra high-performance liquid chromatography tandem mass spectrometry
    Liu, Jia
    Pickford, Russell
    Meagher, Alan P.
    Ward, Robyn L.
    ANALYTICAL BIOCHEMISTRY, 2011, 411 (02) : 210 - 217