Development of a multiplex immunochromatographic strip test and ultrasensitive electrochemical immunosensor for hepatitis B virus screening

被引:36
作者
Akkapinyo, Chutimon [1 ]
Khownarumit, Porntip [2 ]
Waraho-Zhmayev, Dujduan [1 ]
Poo-arporn, Rungtiva P. [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Biol Engn Program, Bangkok 10140, Thailand
[2] King Mongkuts Univ Technol Thonburi, PDTI, Sensor Technol, Bangkok 10150, Thailand
关键词
Hepatitis B; Immunosensor; HBsAg; Impedance spectroscopy; Test strip; SURFACE-ANTIGEN; IMPEDANCE IMMUNOSENSOR; ANTIBODY; IMMOBILIZATION; GOLD; NANOPARTICLES; FUNCTIONALIZATION; IMMUNOASSAY; POLYPYRROLE; ELECTRODES;
D O I
10.1016/j.aca.2019.10.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research proposes two methods for hepatitis B diagnosis including rapid testing and electrochemical assay. For the first method, a multiplex hepatitis B test strip was fabricated to serve as a rapid test for hepatitis B screening. It was developed to simultaneously test three essential serological markers of hepatitis B virus infection including hepatitis B surface antigen (HBsAg), hepatitis B surface antibody (Anti-HBs) and hepatitis B core antibody (Anti-HBc). Gold nanoparticles (GNPs) were used as the signal generator on the test strip. Furthermore, a part of a paper network was incorporated on the strip for the gold-silver enhancement process. This paper network helped in decreasing the analysis time of enhancement and makes the enhancement process easier for rapid testing. The developed test strip was specific for each serological marker. The detection limits of HBsAg, Anti-HBs and Anti-HBc were obtained at 0.5, 0.3 and 0.1 mu g mL(-1), respectively. For the second method, electrochemical impedance spectroscopy (EIS) was applied for HBsAg detection. This method was proposed for quantitative hepatitis B detection. Anti-HBs antibodies were immobilized on a carbon screen printed electrode (SPCE) via the N-ethyl-N'-(3-(dimethylamino)propyl)carbo-diimide/N-hydroxy succinimide (EDC/NHS) couple reaction which reacted with the carboxyl group of the BSA cross-linked film on the electrode. The electrode modification process was characterized by EIS. A linear relationship between delta charge transfer resistance (Delta Rct) and HBsAg concentration was obtained in the range of 5-3000 ng mL(-1) with a detection limit of 2.1 ng mL(-1). This work is appropriate for quantitative analysis because it is a simple and low-cost method to implement as the SPCE is disposable. Therefore, we hope that this research will be useful to improve hepatitis B detection in the future. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 41 条
[11]   Reagentless immunosensing assay via electrochemical impedance for hepatitis B surface antigen monitoring based on polypyrrole and gold nanoparticles as matrices [J].
Fu, YZ ;
Yuan, R ;
Chai, YQ .
CHINESE JOURNAL OF CHEMISTRY, 2006, 24 (01) :59-64
[12]  
Ge SR, 1998, J BIOMAT SCI-POLYM E, V9, P131
[13]   Substantial variation in the hepatitis B surface antigen (HBsAg) in hepatitis B virus (HBV)-positive patients from South Africa: Reliable detection of HBV by the Elecsys HBsAg II assay [J].
Gencay, Mikael ;
Vermeulen, Marion ;
Neofytos, Dionysis ;
Westergaard, Gaston ;
Pabinger, Stephan ;
Kriegner, Albert ;
Seffner, Anja ;
Gohl, Peter ;
Huebner, Kirsten ;
Nauck, Markus ;
Kaminski, Wolfgang E. .
JOURNAL OF CLINICAL VIROLOGY, 2018, 101 :38-43
[14]   An impedimetric DNA sensor based on functionalized magnetic nanoparticles for HIV and HBV detection [J].
Hassen, Walid Mohamed ;
Chaix, Carole ;
Abdelghani, Adnane ;
Bessueille, Francois ;
Leonard, Didier ;
Jaffrezic-Renault, Nicole .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :755-760
[15]   Label-Free Electrochemical Diagnosis of Viral Antigens with Genetically Engineered Fusion Protein [J].
Heo, Nam Su ;
Zheng, Shun ;
Yang, MinHo ;
Lee, Seok Jae ;
Lee, Sang Yup ;
Kim, Hwa-Jung ;
Park, Jung Youn ;
Lee, Chang-Soo ;
Park, Tae Jung .
SENSORS, 2012, 12 (08) :10097-10108
[16]   Electrochemical detection of c-reactive protein based on anthraquinone-labeled antibody using a screen-printed graphene electrode [J].
Jampasa, Sakda ;
Siangproh, Weena ;
Laocharoensuk, Rawiwan ;
Vilaivan, Tirayut ;
Chailapakul, Orawon .
TALANTA, 2018, 183 :311-319
[17]  
Jazayeri Mir Hadi, 2016, Sensing and Bio-Sensing Research, V9, P17, DOI 10.1016/j.sbsr.2016.04.002
[18]  
Kao Jia-Horng, 2008, Expert Rev Gastroenterol Hepatol, V2, P553, DOI 10.1586/17474124.2.4.553
[19]   Influence of EDC/NHS coupling chemistry on stability and cytotoxicity of ZnO nanoparticles modified with proteins [J].
Kelestemur, Seda ;
Altunbek, Mine ;
Culha, Mustafa .
APPLIED SURFACE SCIENCE, 2017, 403 :455-463
[20]  
Krajden Mel, 2005, Can J Infect Dis Med Microbiol, V16, P65