Analytical and numerical analysis on the collapse modes of least-thickness circular masonry arches at decreasing friction

被引:14
作者
Cocchetti, Giuseppe [1 ]
Rizzi, Egidio [2 ]
机构
[1] Politecn Milan, Dipartimento Ingn Civile & Ambientale, Piazza L da Vinci 32, I-20133 Milan, Italy
[2] Univ Bergamo, Dipartimento Ingn & Sci Applicate, Viale G Marconi 5, I-24044 Dalmine, BG, Italy
来源
FRATTURA ED INTEGRITA STRUTTURALE | 2020年 / 14卷 / 51期
关键词
Circular masonry arches; Couplet-Heyman problem; Reducing friction; Purely-rotational mode; Mixed sliding-rotational mode; Purely-sliding mode; MINIMUM THICKNESS; BLOCK STRUCTURES; LIMIT ANALYSIS; THRUST-LINE; STABILITY; STEREOTOMY; LOADS; PIERS;
D O I
10.3221/IGF-ESIS.51.26
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Departing from pioneering Heyman modern rational investigations on the purely-rotational collapse mode of least-thickness circular masonry arches, the hypothesis that joint friction shall be high enough to prevent inter-block sliding is here released. The influence of a reducing Coulomb friction coefficient on the collapse modes of the arch is explicitly inspected, both analytically and numerically, by tracing the appearance of purely-rotational, mixed sliding-rotational and purely-sliding modes. A classical doubly built-in, symmetric, complete semi-circular arch, with radial joints, under self-weight is specifically considered, for a main illustration. The characteristic values of the friction coefficient limiting the ranges associated to each collapse mode arc first analytically derived and then numerically identified, by an independent self-implementation, with consistent outcomes. Explicit analytical representations are provided to estimate the geometric parameters defining the limit equilibrium states of the arch, specifically the minimum thickness to radius ratio, at reducing friction. These formulas, starting from the analysis of classical Heymanian instance of purely-rotational collapse, make new explicit reference to the mixed sliding-rotational collapse mode, arising within a narrow range of limited friction coefficients (or friction angles). The obtained results are consistently compared to existing numerical ones from the competent literature.(1)
引用
收藏
页码:356 / 375
页数:20
相关论文
共 45 条
[41]   Analytical and Numerical Analysis on the Collapse Mode of Circular Masonry Arches [J].
Rizzi, Egidio ;
Cocchetti, Giuseppe ;
Colasante, Giada ;
Rusconi, Fabio .
7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 :467-472
[42]   Modern formulation for preelastic theories on masonry arches [J].
Sinopoli, A ;
Corradi, M ;
Foce, F .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1997, 123 (03) :204-213
[43]  
Sinopoli A, 2007, P 5 INT C ARCH BRIDG, P649
[44]  
Smars P, 2000, Doctoral Thesis, P229
[45]  
Smars P, 2008, STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTION: PRESERVING SAFETY AND SIGNIFICANCE, VOLS 1 AND 2, P1199