Nerve stimulation with a multi-contact cuff electrode: Validation of model predictions

被引:11
|
作者
Deurloo, KEI [1 ]
Holsheimer, J [1 ]
Bergveld, P [1 ]
机构
[1] Univ Twente, Dept Elect Engn, Inst Biomed Technol, NL-7500 AE Enschede, Netherlands
关键词
rabbit; nerve stimulation; cuff electrode; selective stimulation; sciatic nerve;
D O I
10.1076/apab.108.4.349.4301
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The recruitment characteristics of muscle selective nerve stimulation by a multi-contact nerve cuff electrode, as predicted by computer modeling, have been investigated in acute experiments on rabbits. A nerve cuff containing five or six dot electrodes was placed around the sciatic nerve in five rabbits. M-waves were recorded with wire electrodes from the lateral gastrocnemius, soleus, tibialis anterior, and extensor digitorum longus muscles. The muscle recruitment performances of three contact configurations (monopole, transverse bipole, transverse tripole) were compared. The selectivity was quantified by the recruitment of two muscles (one extensor and one flexor) in response to a particular stimulus. The results showed that only in a few cases, transverse bi- and tripolar stimulation provided a better selectivity than monopolar stimulation. Neither of the two extensors, nor of the two flexors could be stimulated separately. In accordance with the results of the modeling studies, bi- and tripolar stimulation required higher stimulus currents than monopolar stimulation, whereas maximum recruitment and slopes of recruitment curves were lower. The rabbit sciatic nerve appears to be a less suitable preparation for reproducible selectivity experiments, due to the variability in the number and size of the fascicles and their position in this nerve.
引用
收藏
页码:349 / 359
页数:11
相关论文
共 26 条
  • [21] Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer
    Sabetian, Parisa
    Sadeghlo, Bita
    Zhang, Chengran Harvey
    Yoo, Paul B.
    MEDICAL ENGINEERING & PHYSICS, 2017, 40 : 39 - 46
  • [22] Design and Simulation of a Parylene-based Three-Dimensional Cuff Electrode for peripheral nerve stimulation
    Xiong, Wenjie
    Yu, Huaiqiang
    Li, Zhihong
    MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 1459 - 1463
  • [23] Model-based analysis and design of nerve cuff electrodes for restoring bladder function by selective stimulation of the pudendal nerve
    Kent, Alexander R.
    Grill, Warren M.
    JOURNAL OF NEURAL ENGINEERING, 2013, 10 (03)
  • [24] A combined cuff electrode array for organ-specific selective stimulation of vagus nerve enabled by Electrical Impedance Tomography
    Ravagli, Enrico
    Ardell, Jeffrey
    Holder, David
    Aristovich, Kirill
    FRONTIERS IN MEDICAL TECHNOLOGY, 2023, 5
  • [25] Acute in vivo testing of a polymer cuff electrode with integrated microfluidic channels for stimulation, recording, and drug delivery on rat sciatic nerve
    Elyahoodayan, Sahar
    Larson, Christopher
    Cobo, Angelica M.
    Meng, Ellis
    Song, Dong
    JOURNAL OF NEUROSCIENCE METHODS, 2020, 336
  • [26] Model-based geometrical optimisation and in vivo validation of a spatially selective multielectrode cuff array for vagus nerve neuromodulation
    Aristovich, Kirill
    Donega, Matteo
    Fjordbakk, Cathrine
    Tarotin, Ilya
    Chapman, Christopher A. R.
    Viscasillas, Jaime
    Stathopoulou, Thaleia-Rengina
    Crawford, Abbe
    Chew, Daniel
    Perkins, Justin
    Holder, David
    JOURNAL OF NEUROSCIENCE METHODS, 2021, 352