Smith Prediction Monitor AGC System Based on Fuzzy Self-Tuning PID Control

被引:40
作者
Sun Jie [1 ]
Zhang Dian-hua [1 ]
Li Xu [1 ]
Zhang Jin [1 ]
Du De-shun [1 ]
机构
[1] Northeastern Univ, State Key Lab Rolling & Automat, Shenyang 110004, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
monitor AGC; fuzzy self-tuning PID control; Smith predictor; position control; DEAD-TIME COMPENSATOR;
D O I
10.1016/S1006-706X(10)60053-2
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
In accordance with the feature of pure delay in monitor AGC system for cold rolling mill, a new fuzzy self-tuning PID Smith prediction controller is developed. The position control model is deduced based on a single stand cold rolling mill, and the fuzzy controller for monitor AGC system is designed. The analysis of dynamic performance for traditional PID Smith prediction controller and fuzzy self-tuning PID Smith prediction controller is done by MATLAB toolbox. The simulation results show that fuzzy self-tuning PID Smith controller has stronger robustness, faster response and higher static accuracy than traditional PID Smith controller.
引用
收藏
页码:22 / 26
页数:5
相关论文
共 11 条
[1]  
DING Xiu-kun, 2002, ROLLING PROCESS AUTO
[2]  
FANG YM, 2002, AUTOMATION INSTRUMEN, P6
[3]  
HAN LQ, 2004, J HEBEI U, P131
[4]  
[何立平 HE Liping], 2006, [钢铁研究学报, Journal of Iron and Steel Research], V18, P23
[5]   Improving performance using cascade control and a Smith predictor [J].
Kaya, I .
ISA TRANSACTIONS, 2001, 40 (03) :223-234
[6]  
Liu J.C., 1998, IRON STEEL, V33, P40
[7]   STABILITY PROPERTIES OF SMITH DEAD-TIME COMPENSATOR CONTROLLERS [J].
PALMOR, Z .
INTERNATIONAL JOURNAL OF CONTROL, 1980, 32 (06) :937-949
[8]   AN AUTO-TUNER FOR SMITH DEAD-TIME COMPENSATOR [J].
PALMOR, ZJ ;
BLAU, M .
INTERNATIONAL JOURNAL OF CONTROL, 1994, 60 (01) :117-135
[9]  
Qi CY, 2003, J IRON STEEL RES INT, V10, P28
[10]  
Smith O. J., 1957, CHEM ENG PROG, V53, P217