Quantification of Hydrazine in Human Urine by HPLC-MS-MS

被引:6
作者
Isenberg, Samantha L. [1 ]
Carter, Melissa D. [2 ]
Crow, Brian S. [2 ]
Graham, Leigh Ann [1 ]
Johnson, Darryl [3 ]
Beninato, Nick [4 ]
Steele, Kandace [3 ]
Thomas, Jerry D. [2 ]
Johnson, Rudolph C. [2 ]
机构
[1] Ctr Dis Control & Prevent, Battelle Mem Inst, Atlanta, GA 30341 USA
[2] Ctr Dis Control & Prevent, Div Lab Sci, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[3] Ctr Dis Control & Prevent, Oak Ridge Inst Sci & Educ, Atlanta, GA 30341 USA
[4] Chem Threat Analyt Response Sect, Div Sci Lab, New Mexico Dept Hlth, Albuquerque, NM, Mexico
关键词
METABOLISM; MECHANISM; EXPOSURE;
D O I
10.1093/jat/bkw015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Currently used on F-16 fighter jets and some space shuttles, hydrazine could be released at toxic levels to humans as a result of an accidental leakage or spill. Lower-level exposures occur in industrial workers or as a result of the use of some pharmaceuticals. A method was developed for the quantitation of hydrazine in human urine and can be extended by dilution with water to cover at least six orders of magnitude, allowing measurement at all clinically significant levels of potential exposure. Urine samples were processed by isotope dilution, filtered, derivatized and then quantified by HPLC-MS-MS. The analytical response ratio was linearly proportional to the urine concentration of hydrazine from 0.0493 to 12.3 ng/mL, with an average correlation coefficientR of 0.9985. Inter-run accuracy for 21 runs, expressed as percent relative error (% RE), was a parts per thousand currency sign14%, and the corresponding precision, expressed as percent relative standard deviation (% RSD), was a parts per thousand currency sign15%. Because this method can provide a quantitative measurement of clinical samples over six orders of magnitude, it can be used to monitor trace amounts of hydrazine exposure as well as industrial and environmental exposure levels.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 34 条
[1]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]  
[Anonymous], 1999, IARC Monogr Eval Carcinog Risks Hum, V71 Pt 3, P991
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], 2014, REP CARC
[5]  
ATSDR, 1997, TOX PROF HYDR
[6]   Determination of hydrazine in a meningococcal C conjugate vaccine intermediary product [J].
Bastos, Renata Chagas ;
de Carvalho, Juliana Machado ;
Freitas Brasileiro da Silveira, Ivna Alana ;
Jacob, Silvana do Couto ;
Leandro, Katia Christina .
VACCINE, 2010, 28 (34) :5648-5651
[7]   PLASMA HYDRAZINE CONCENTRATIONS IN MAN AFTER ISONIAZID AND HYDRALAZINE ADMINISTRATION [J].
BLAIR, IA ;
TINOCO, RM ;
BRODIE, MJ ;
CLARE, RA ;
DOLLERY, CT ;
TIMBRELL, JA ;
BEEVER, IA .
HUMAN TOXICOLOGY, 1985, 4 (02) :195-202
[8]   Stability of isoniazid in isoniazid syrup: formation of hydrazine [J].
Carlin, A ;
Gregory, N ;
Simmons, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) :885-890
[9]   Multi-rule quality control for the age-related eye disease study [J].
Caudill, Salntlel P. ;
Schleicher, Rosemary L. ;
Pirkle, James L. .
STATISTICS IN MEDICINE, 2008, 27 (20) :4094-4106
[10]  
Clark J. D., 1972, IGNITION INFORMAL HI, P13