Use of polar decomposition for the diagnosis of oral precancer

被引:81
作者
Chung, Jungrae [1 ]
Jung, Woonggyu
Hammer-Wilson, Marie J.
Wilder-Smith, Petra
Chen, Zhongping
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92612 USA
关键词
D O I
10.1364/AO.46.003038
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Mueller matrix describes all the polarizing properties of a sample and, therefore, the optical differences between noncancerous and precancerous tissue that may be present within the matrix elements. A high-speed polarimetry system that generates 16 (4 x 4) full Mueller matrices to characterize tissues is presented. Feature extraction is done on the Mueller matrix elements resulting in depolarization and retardance images by polar decomposition. These are used to detect and classify early oral cancers and precancerous changes in epithelium such as dysplasia. These images are compared with orthogonal polarization images and analyzed in an attempt to identity useful factors for the differentiation between cancerous lesions and their benign counterparts. Our results indicate that polarimetry has potential as a method for the in vivo early detection and diagnosis of oral premalignancy. (C) 2007 Optical Society of America.
引用
收藏
页码:3038 / 3045
页数:8
相关论文
共 37 条
[1]   Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine) [J].
Xu, JJ ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :101-106
[2]   Development and calibration of an automated Mueller matrix polarization imaging system [J].
Baba, JS ;
Chung, JR ;
DeLaughter, AH ;
Cameron, BD ;
Coté, GL .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :341-349
[3]   APPLICATION OF POLARIZATION EFFECTS IN LIGHT-SCATTERING - NEW BIOPHYSICAL TOOL [J].
BICKEL, WS ;
DAVIDSON, JF ;
HUFFMAN, DR ;
KILKSON, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1976, 73 (02) :486-490
[4]   Polarimetry using liquid-crystal variable retarders: theory and calibration [J].
Bueno, JM .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2000, 2 (03) :216-222
[5]   Measurement and calculation of the two-dimensional backscattering Mueller matrix of a turbid medium [J].
Cameron, BD ;
Rakovic, MJ ;
Mehrubeoglu, M ;
Kattawar, GW ;
Rastegar, S ;
Wang, LV ;
Cote, GL .
OPTICS LETTERS, 1998, 23 (07) :485-487
[6]   Measurement and calculation of the two-dimensional backscattering Mueller matrix of a turbid medium (vol 23, pg 485, 1998) [J].
Cameron, BD ;
Rakovic, MJ ;
Mehrubeoglu, M ;
Kattawar, GW ;
Rastegar, S ;
Wang, LV ;
Cote, GL .
OPTICS LETTERS, 1998, 23 (20) :1630-1630
[7]   Automated high-speed Mueller matrix scatterometer [J].
Delplancke, F .
APPLIED OPTICS, 1997, 36 (22) :5388-5395
[8]   Optical polarization imaging [J].
Demos, SG ;
Alfano, RR .
APPLIED OPTICS, 1997, 36 (01) :150-155
[9]   Deep subsurface imaging in tissues using spectral and polarization filtering [J].
Demos, SG ;
Radousky, HB ;
Alfano, RR .
OPTICS EXPRESS, 2000, 7 (01) :23-28
[10]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76