Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)

被引:8
作者
Liu, Xin [2 ]
Feng, Yi [3 ]
Lu, Zheng-Rong [4 ]
Morrell, Glen
Jeong, Eun-Kee [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Salt Lake City, UT 84108 USA
[3] Univ Utah, Dept Mat Engn, Salt Lake City, UT 84108 USA
[4] Univ Utah, Dept Pharmaceut & Pharmaceut Chem, Salt Lake City, UT 84108 USA
关键词
T-1/T-2; maps; T-1; map; T-2; rapid T-1/T-2 maps; simultaneous T-1/T-2 maps; Delta R-1(r; t) map; multishot double spin-echo EPI; dynamic contrast MRI; GD-DTPA ENHANCEMENT; PHARMACOKINETIC ANALYSIS; GADOLINIUM-DTPA; CONTRAST AGENT; MRI; PERMEABILITY; EXPERIENCE; TUMORS;
D O I
10.1002/nbm.1440
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A rapid method of simultaneous T-1 and T-2 measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TIE). This method is useful in T-1 mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T-1 can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T-1 calculations for improved accuracy. Simultaneous T-2 measurement allows correction of T-2 effects in the T-1 map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 26 条
  • [1] PROTON RELAXATION TIMES IN PARAMAGNETIC SOLUTIONS
    BLOEMBERGEN, N
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1957, 27 (02) : 572 - 573
  • [2] RELAXATION EFFECTS IN NUCLEAR MAGNETIC RESONANCE ABSORPTION
    BLOEMBERGEN, N
    PURCELL, EM
    POUND, RV
    [J]. PHYSICAL REVIEW, 1948, 73 (07): : 679 - 712
  • [3] Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series
    Brix, G
    Kiessling, F
    Lucht, R
    Darai, S
    Wasser, K
    Delorme, S
    Griebel, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) : 420 - 429
  • [4] Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience
    Brix, G
    Bahner, ML
    Hoffmann, UJ
    Horvath, A
    Schreiber, W
    [J]. RADIOLOGY, 1999, 210 (01) : 269 - 276
  • [5] Microvessel density in invasive breast cancer assessed by dynamic Gd-DTPA enhanced MRI
    Buckley, DL
    Drew, PJ
    Mussurakis, S
    Monson, JRT
    Horsman, A
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 461 - 464
  • [6] GADOLINIUM-DTPA AS A CONTRAST AGENT IN MRI - INITIAL CLINICAL-EXPERIENCE IN 20 PATIENTS
    CARR, DH
    BROWN, J
    BYDDER, GM
    STEINER, RE
    WEINMANN, HJ
    SPECK, U
    HALL, AS
    YOUNG, IR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (02) : 215 - 224
  • [7] ULTRA-FAST IMAGING
    COHEN, MS
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IMAGING, 1991, 9 (01) : 1 - 37
  • [8] A MRI spatial mapping technique for microvascular permeability and tissue blood volume based on macromolecular contrast agent distribution
    Demsar, F
    Roberts, TPL
    Schwickert, HC
    Shames, DM
    vanDijke, CF
    Mann, JS
    Saeed, M
    Brasch, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 236 - 242
  • [9] Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    Deoni, SCL
    Rutt, BK
    Peters, TM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 515 - 526
  • [10] MUSCULOSKELETAL NEOPLASMS - STATIC AND DYNAMIC GD-DTPA ENHANCED MR IMAGING
    ERLEMANN, R
    REISER, MF
    PETERS, PE
    VASALLO, P
    NOMMENSEN, B
    KUSNIERZGLAZ, CR
    RITTER, J
    ROESSNER, A
    [J]. RADIOLOGY, 1989, 171 (03) : 767 - 773