Position referencing in optical microscopy thanks to sample holders with out-of-focus encoded patterns

被引:21
作者
Sandoz, P. [1 ]
Zeggari, R.
Froehly, L.
Pretet, J. -L.
Mougin, C.
机构
[1] Univ Franche Comte, Dept Opt PM Duffieux, CNRS, Inst FEMTO ST,UMR 6174, F-25030 Besancon, France
[2] Univ Franche Comte, Lab Biol Cellulaire & Mol, EA 3181, IFR133,CHU Jean Minjoz, F-25030 Besancon, France
关键词
encoded patterns; optical microscopy; phase measurements; position referencing; video-microscopy; site-by-site comparison;
D O I
10.1111/j.1365-2818.2007.01745.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
This article introduces smart sample holders for optical microscopy. Their purpose is to allow the absolute determination of the position of the observed zone with respect to the sample holder itself and with a high accuracy. It becomes then straightforward to find a given zone of interest by positioning coarsely the microscope slide to the same position coordinates. Furthermore images recorded during different observation sessions; i.e. for slightly different positions; can be processed numerically in order to superimpose them with a high accuracy. Thus the slight deviations of the microscope slide position and orientation due to the different observations are compensated numerically and a perfect superimposition of the recorded images is performed. Then accurate site-by-site image comparisons become possible even for images recorded during different observation sessions and over a long period of time. The subpixel capability of the proposed method is demonstrated and those smart microscope slides constitute a new tool for live cell experiment. In practise, an encoded geometrical pattern used as position reference is inserted in a plane parallel to the surface receiving the tissue section or sample. Then the transition of the focus position from the tissue section to the position reference requires only a vertical adjustment and does not affect the lateral coordinates of observation. The numeric processing of the image of the position reference pattern allows the retrieval of the lateral coordinates that are also used for the tissue section image. Thus each image is recorded with a set of position coordinates that defines accurately the position of the observed area with respect to the sample holder itself.
引用
收藏
页码:293 / 303
页数:11
相关论文
共 14 条
[1]   Imaging intracellular fluorescent proteins at nanometer resolution [J].
Betzig, Eric ;
Patterson, George H. ;
Sougrat, Rachid ;
Lindwasser, O. Wolf ;
Olenych, Scott ;
Bonifacino, Juan S. ;
Davidson, Michael W. ;
Lippincott-Schwartz, Jennifer ;
Hess, Harald F. .
SCIENCE, 2006, 313 (5793) :1642-1645
[2]   APPLICATIONS OF DIGITAL-IMAGE-CORRELATION TECHNIQUES TO EXPERIMENTAL MECHANICS [J].
CHU, TC ;
RANSON, WF ;
SUTTON, MA ;
PETERS, WH .
EXPERIMENTAL MECHANICS, 1985, 25 (03) :232-244
[3]  
de Coulon F., 1984, THEORIE TRAITEMENT S
[4]  
Golomb S. W., 1967, Shift Register Sequences
[5]  
Max J., 1996, METHODES TECHNIQUES, V1
[6]   Method of obtaining optical sectioning by using structured light in a conventional microscope [J].
Neil, MAA ;
Juskaitis, R ;
Wilson, T .
OPTICS LETTERS, 1997, 22 (24) :1905-1907
[7]   STRAIN-MEASUREMENT USING GRIDS [J].
PARKS, VJ .
OPTICAL ENGINEERING, 1982, 21 (04) :633-639
[8]   Phase-sensitive vision technique for high accuracy position measurement of moving targets [J].
Sandoz, P ;
Ravassard, JC ;
Dembélé, S ;
Janex, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) :867-872
[9]   Micro-structured surface-element for high-accuracy position measurement by vision and phase-measurement [J].
Sandoz, P ;
Trolard, B ;
Marsaut, D ;
Gharbi, T .
RIAO/OPTILAS 2004: 5TH IBEROAMERICAN MEETING ON OPTICS AND 8TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, PTS 1-3: ICO REGIONAL MEETING, 2004, 5622 :606-611
[10]   High-accuracy position and orientation measurement of extended two-dimensional surfaces by a phase-sensitive vision method [J].
Sandoz, P ;
Bonnans, V ;
Gharbi, T .
APPLIED OPTICS, 2002, 41 (26) :5503-5511