X-ray micro-CT scanner for small animal imaging based on Timepix detector technology

被引:17
作者
Dudak, Jan [1 ,2 ]
Zemlicka, Jan [1 ]
Krejci, Frantisek [1 ]
Polansky, Stepan [1 ]
Jakubek, Jan [1 ]
Mrzilkova, Jana [3 ]
Patzelt, Matej [3 ]
Trnka, Jan [3 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, Prague 12800 2, Czech Republic
[2] Czech Tech Univ, Fac Biomed Engn, Kladno 27200, Czech Republic
[3] Charles Univ Prague, Fac Med 3, Prague 10000, Czech Republic
关键词
Computerized tomography; Hybrid detector; Timepix; Small animal imaging; COMPUTED TOMOGRAPHY; MICROTOMOGRAPHY; RESOLUTION;
D O I
10.1016/j.nima.2014.10.076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a newly developed compact micro-CT scanner with rotating gantry equipped with a Timepix Quad hybrid pixel semiconductor detector and a micro-focus X-ray tube providing spatial resolution down to 30 mu m. The resolving power of the device in relation to soft tissue sensitivity is demonstrated using a tissue-equivalent phantom and different types of biological samples. The results demonstrate that the use of noiseless particle counting detectors is a promising way to achieve sufficient soft tissue contrast even without any contrast agents. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 19 条
[1]   Evaluation of tissue-equivalent materials to be used as human brain tissue substitute in dosimetry for diagnostic radiology [J].
Ferreira, C. C. ;
Ximenes Filho, R. E. M. ;
Vieira, J. W. ;
Tomal, A. ;
Poletti, M. E. ;
Garcia, C. A. B. ;
Maia, A. F. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (16) :2515-2521
[2]   Comparison of single-photon counting and charge-integrating detectors for X-ray high-resolution imaging of small biological objects [J].
Frallicciardi, Paola Maria ;
Jakubek, Jan ;
Vavrik, Daniel ;
Dammer, Jiri .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :221-222
[3]   Characterization of Tissue-Equivalent Materials Through Measurements of the Linear Attenuation Coefficient and Scattering Profiles Obtained With Polyenergetic Beams [J].
Geraldelli, Wender ;
Tomal, Alessandra ;
Poletti, Martin E. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) :566-571
[4]   Large area pixel detector WIDEPIX with full area sensitivity composed of 100 Timepix assemblies with edgeless sensors [J].
Jakubek, J. ;
Jakubek, M. ;
Platkevic, M. ;
Soukup, P. ;
Turecek, D. ;
Sykora, V. ;
Vavrik, D. .
JOURNAL OF INSTRUMENTATION, 2014, 9
[5]   Resolution and stability tests of a Medipix-1 pixel detector for X-ray dynamic defectoscopy [J].
Jakubek, J ;
Pospísil, S ;
Vavrík, D ;
Visschers, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :294-301
[6]   Energy-sensitive X-ray radiography and charge sharing effect in pixelated detector [J].
Jakubek, Jan .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :192-195
[7]   Micro-computed tomography with iodine staining resolves the arrangement of muscle fibres [J].
Jeffery, Nathan S. ;
Stephenson, Robert S. ;
Gallagher, James A. ;
Jarvis, Jonathan C. ;
Cox, Philip G. .
JOURNAL OF BIOMECHANICS, 2011, 44 (01) :189-192
[8]   FITPix - fast interface for Timepix pixel detectors [J].
Kraus, V. ;
Holik, M. ;
Jakubek, J. ;
Kroupa, M. ;
Soukup, P. ;
Vykydal, Z. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[9]   X-ray microtomography [J].
Landis, Eric N. ;
Keane, Denis T. .
MATERIALS CHARACTERIZATION, 2010, 61 (12) :1305-1316
[10]   Micro-computed tomography for small animal imaging: Technological details [J].
Li, Hao ;
Zhang, Hui ;
Tang, Zhiwei ;
Hu, Guangshu .
PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2008, 18 (05) :513-521