Short-Circuit Analysis of DER-Based Microgrids in Connected and Islanded Modes of Operation

被引:6
作者
Simic, Nikola [1 ]
Strezoski, Luka [1 ]
Dumnic, Boris [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Dept Power Elect & Telecommun Engn, Novi Sad 21000, Serbia
关键词
fault current; short circuit; microgrid; distributed energy resources; LOAD FLOW; PROTECTION;
D O I
10.3390/en14196372
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Since microgrids should be able to smoothly operate in two distinct modes-grid-connected and islanded, their fault currents can widely fluctuate depending on the operational mode. When the microgrid is connected to the grid, the highest fault current, by far, is supplied by the utility grid. In this mode, the fault current contribution from distributed energy resources (DERs) is less than 20%. However, when the microgrid switches to the islanded mode, the fault current contribution from the utility grid is lost and DERs are the sole fault current sources. Thus, the overall fault current in the islanded mode is multiple times lower when compared to the grid connected mode. Moreover, most of the DERs are inverter-based, with limited fault currents, which further reduces the overall fault current in the islanded mode. With the rapid rise of the microgrid penetration around the globe, this phenomenon can adversely influence the relay protection, and thus the microgrid fault current needs to be precisely analyzed. Therefore, the main purpose of this paper is to thoroughly analyze the fault current differences in two distinct operation modes of a microgrid, and to consequently derive conclusions regarding the required improvements in fault calculations and relay protection analysis in emerging microgrids. A representative microgrid test bed is developed and modelled using the in-house developed software as well as in a state-of-the-art hardware-in-the-loop environment. Several different short-circuit faults were simulated and analyzed in both grid-connected and islanded modes. The results show that the fault currents significantly differ depending on the operating mode, and thus highly influence the protection system. Moreover, test results show that the fault calculation algorithms aimed at radial distribution grids, mostly used for microgrid fault calculations in the available literature, need to be further improved to provide precise and time-efficient results when the emerging microgrids are considered. These results provide a valuable insight into the current state of the microgrids' fault calculation and protection and reveal several important directions for future research.
引用
收藏
页数:16
相关论文
共 28 条
[1]   Optimal Microgrid-Interactive Reactive Power Management for Day-Ahead Operation [J].
Acosta, Martha N. ;
Gonzalez-Longatt, Francisco ;
Topic, Danijel ;
Andrade, Manuel A. .
ENERGIES, 2021, 14 (05)
[2]  
[Anonymous], 2006, 50003024 CONS EL REL
[3]  
[Anonymous], 2008, Power System Relaying
[4]  
[Anonymous], P 2008 40 N AM POW S
[5]  
[Anonymous], 2000, POWER SYSTEM ANAL
[6]   A survey on adaptive protection of microgrids and distribution systems with distributed generators [J].
Barra, P. H. A. ;
Coury, D. V. ;
Fernandes, R. A. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 118
[7]  
Bruce M, 2007, Principles of Regenerative Biology, P1, DOI [10.1016/B978-012369439-3/50003-9, DOI 10.1016/B978-012369439-3/50003-9]
[8]  
Celanovi c I., 2010, PROC 15 INT S POWER, P15
[9]   Static Modeling of Microgrids for Load Flow and Fault Analysis [J].
Dag, Bulent ;
Boynuegri, Ali Rifat ;
Ates, Yavuz ;
Karakas, Arif ;
Nadar, Abdullah ;
Uzunoglu, Mehmet .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (03) :1990-2000
[10]  
Gers J.M., 2011, PROTECTION ELECT DIS