Endometrium imaging using real-time rotational optical coherence tomography imaging system A pilot, prospective and ex-vivo study

被引:5
|
作者
Law, Tracy Sze Man [1 ]
Wu, Fangrong [1 ]
Xu, Hui [1 ]
Wang, Chi Chiu [1 ,2 ,3 ]
Li, Tin Chiu [1 ]
机构
[1] Chinese Univ Hong Kong, Fac Med, Dept Obstet & Gynaecol, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Fac Med, Li Ka Shing Inst Hlth Sci, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Fac Med, Sch Biomed Sci, Shatin, Hong Kong, Peoples R China
关键词
endometrium; gynecology; optical coherence; tomography; uterus; COLPOSCOPY; AGREEMENT; ACCURACY;
D O I
10.1097/MD.0000000000017738
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to evaluate a novel real-time rotational optical coherence tomography (OCT) imaging system (OCTIS) with a fiber-optic probe to look at endometrium and to correlate the OCTIS images with standard histology. OCT could obtain real-time images resembling histological examination. With recent development of customized probes, it allows OCT to be used in the field of gynecology. This is a pilot, prospective, ex-vivo and observational study. Women underwent hysterectomy for various gynecological conditions were recruited and OCTIS images were obtained from endometrium of 15 fresh uterus specimens immediately after hysterectomy. The excised uterus was cut open and OCTIS imaging was obtained. The scanned region of endometrium was excised for histological examination and OCTIS images were precisely compared to corresponding histological images and ultrasound images. Blinded qualitative analysis on OCTIS images was performed by 2 assessors to determine inter-rating reliability on the histopathological diagnosis. Epithelium, glands, cysts, and stroma of endometrium were clearly seen by the OCTIS. Different phases of menstrual cycle of normal endometrium could be differentiated and pathological condition such as hyperplastic and dysplasic endometrium, which corresponded well with histological findings, could be identified. The inter-rater reliability between assessors on overall OCTIS endometrium and neoplastic OCTIS endometrium was moderate (Kendall tau b of 0.58) and substantial (Kendall tau b of 0.76), respectively. OCTIS can provide real-time, high-resolution and rotational imaging modality to view endometrial structure with high consistency with histological examination and satisfactory agreement between observers. It has a great potential to be developed in the clinical use of endometrial assessment for gynecological applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Real-time retinal imaging with a parallel optical coherence tomography using a CMOS smart array detector
    Kim, Jeehyun
    Sohn, Bong-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (05) : 1787 - 1791
  • [42] Integrated Optical Coherence Tomography and Optical Coherence Microscopy Imaging of Ex Vivo Human Renal Tissues
    Lee, Hsiang-Chieh
    Zhou, Chao
    Cohen, David W.
    Mondelblatt, Amy E.
    Wang, Yihong
    Aguirre, Aaron D.
    Shen, Dejun
    Sheikine, Yuri
    Fujimoto, James G.
    Connolly, James L.
    JOURNAL OF UROLOGY, 2012, 187 (02): : 691 - 699
  • [43] Ex-vivo Imaging of Thyroid Gland Using Ultrahigh-Resolution Optical Coherence Tomography at Wavelength from 800 to 1700 nm
    Ishida, Shutaro
    Nishizawa, Norihiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (03)
  • [44] High-velocity-flow imaging with real-time Doppler optical coherence tomography
    Villey, Richard
    Carrion, Lionel
    Morneau, Dominic
    Boudoux, Caroline
    Maciejko, Roman
    APPLIED OPTICS, 2010, 49 (16) : 3140 - 3149
  • [45] Intravesical real-time imaging and staging of bladder cancer: Use of optical coherence tomography
    Sengottayan, Vengetesh K.
    Vasudeva, Pawan
    Dalela, Divakar
    INDIAN JOURNAL OF UROLOGY, 2008, 24 (04) : 592 - 593
  • [46] Miniature real-time intraoperative forward-imaging optical coherence tomography probe
    Joos, Karen M.
    Shen, Jin-Hui
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1342 - 1350
  • [47] Ultrahigh resolution ex vivo ocular imaging using ultrashort acquisition time en face optical coherence tomography
    Grieve, K
    Moneron, G
    Dubois, A
    Le Gargasson, JF
    Boccara, C
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2005, 7 (08): : 368 - 373
  • [48] Real-time imaging for Spectral Optical Coherence Tomography with massively parallel data processing
    Sylwestrzak, Marcin
    Szkulmowski, Maciej
    Szlag, Daniel
    Targowski, Piotr
    PHOTONICS LETTERS OF POLAND, 2010, 2 (03) : 137 - 139
  • [49] Co-registered photoacoustic and ultrasound real-time imaging of colorectal cancer: ex-vivo studies
    Yang, Guang
    Amidi, Eghbal
    Chapman, William, Jr.
    Nandy, Sreyankar
    Mostafa, Atahar
    Abdelal, Heba
    Alipour, Zahra
    Chatterjee, Deyali
    Mutch, Matthew
    Zhu, Quing
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2019, 2019, 10878
  • [50] REAL-TIME IMAGING WITH THE O-ARM OF LUNG PARENCHYMA DURING EX-VIVO LUNG RECONDITIONING
    De Wolf, J.
    Glorion, M.
    Puyo, P.
    Bonnette, P.
    Roux, A.
    Le Guen, M.
    Parquin, F.
    Chapelier, A.
    Sage, E.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 12 - 12