Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation

被引:27
作者
Frenkel, S [1 ]
Slonim, E [1 ]
Horani, A [1 ]
Molcho, M [1 ]
Barzel, I [1 ]
Blumenthal, EZ [1 ]
机构
[1] Hebrew Univ Jerusalem, Hadassah Med Ctr, Dept Ophthalmol, Jerusalem, Israel
关键词
D O I
10.1016/j.ophtha.2004.08.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To ascertain operator learning effect, and to quantify the interoperator reproducibility, using the newly introduced GDx VCC (variable corneal compensator) scanning laser polarimeter. Design: Prospective instrument validation study. Participants: Three operators with no prior experience in operating the GDx VCC examined one randomly chosen eye of each of 30 randomly ordered subjects (15 glaucoma patients and 15 normal subjects). Methods: Each study eye was scanned by the 3 operators in a random sequence during a single session. Five GDx parameters were analyzed: TSNIT (temporal, superior, nasal, inferior, temporal) Average, TSNIT Standard Deviation (SID), Superior Average, Inferior Average, and Nerve Fiber Indicator (NFI). Main Outcome Measures: Retinal nerve fiber layer (RNFL) thickness GDx parameters across operators. Results: A learning effect was not found for any of the operators for any of the 5 GDx parameters studied. Reproducibility for each GDx parameter was measured as the mean SID value of the measurements taken by the 3 operators. Interoperator reproducibilities for normal and glaucomatous eyes, respectively, were 0.8 and 1.6 mum (TSNIT Average), 1.7 and 2.2 mum (Superior Average), 1.6 and 2.7 mum (Inferior Average), 1.3 and 1.7 mum (TSNIT SID), and 1.4 and 4.6 mum (NFI). The data obtained by each operator were highly correlated with those of the other 2 operators. Conclusions: With the commercially available GDx VCC, a learning effect was not found for 3 novice operators. In addition, RNFL measurements seem highly reproducible across operators. (C) 2005 by the American Academy of Ophthalmology.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 13 条
[1]   Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[2]  
BLUMENTHAL EZ, IN PRESS EYE
[3]  
BURK RO, 1998, CURR OPIN OPHTHALMOL, V9, P71
[4]  
Garway-Health DF, 2002, INVEST OPHTH VIS SCI, V43, P1465
[5]  
*GDX VCC, GDX VCC COMP PROGR V
[6]   Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Huang, XR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (06) :715-722
[7]  
*JMP, 2003, JMP COMP PROGR VERS
[8]  
Kook MS, 2001, GRAEF ARCH CLIN EXP, V239, P118
[9]  
OSSOINIG K C, 1979, International Ophthalmology Clinics, V19, P127, DOI 10.1097/00004397-197901940-00007
[10]  
Sample PA, 2000, INVEST OPHTH VIS SCI, V41, P1783