Experimental evaluation of the influence of infiltration on the efficiency of solar flat plate collectors

被引:0
|
作者
Paiva, Elisiane S. A. [1 ]
Diniz, Antonia Sonia A. C. [1 ]
Faria, Lucas P. P. [1 ]
Silverio, Thiago A. [1 ]
Barreto, Rafael O. [1 ]
Maia, Cristiana B. [1 ]
机构
[1] Pontifical Catholic Univ Minas Gerais PUCMinas, Dept Mech Engn, Belo Horizonte, MG, Brazil
关键词
Efficiency; Solar collector; Infiltration; RESIDENTIAL SECTOR; PERFORMANCE; NANOFLUIDS;
D O I
10.18086/swc.2015.10.15
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PBE (Brazilian Labeling Program) is a national program in Brazil that aims to establish standard criteria to compare the energetic efficiency and quality of several devices, such as refrigerators, vehicles, and flat plate solar collectors. The vast majority of solar collectors tested by PBE fail in the topic of infiltration of water condensation. Arguably, the presence of water inside the collector decreases its efficiency, since part of the solar radiation is lost to heat the infiltrated water. However, the determination of the heat losses due to infiltration has not yet been proven in actual flat plate solar collectors, since it has not yet been properly measured. The aim of this study was to evaluate the influence of water infiltration in the efficiency of flat plate solar collectors, evaluating devices from three classes of energetic efficiency: A, B, and C. For the samples evaluated, it was observed that the influence of the amount of water infiltrated on the efficiency is not significant. Therefore, this criterion should not be used to promote the rejection of the collector.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 50 条
  • [11] EFFECT OF CONTACT SPACING ON EFFICIENCY OF FLAT-PLATE SOLAR COLLECTORS
    CRHA, S
    SCHNEIDER, GE
    JOURNAL OF SPACECRAFT AND ROCKETS, 1985, 22 (06) : 585 - 591
  • [12] A review on solar flat plate collectors
    Jebaraj, S.
    Al-Qahtani, Ali Mubarak
    INTERNATIONAL JOURNAL OF GLOBAL ENERGY ISSUES, 2021, 43 (2-3) : 114 - 134
  • [13] Characterization of solar flat plate collectors
    Cruz-Peragon, F.
    Palomar, J. M.
    Casanova, P. J.
    Dorado, M. P.
    Manzano-Agugliaro, F.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (03): : 1709 - 1720
  • [14] Experimental calculation of the mean temperature of flat plate thermal solar collectors
    Seco-Nicolas, Manuel
    Alarcon Garcia, Mariano
    Pedro Luna-Abad, Juan
    RESULTS IN ENGINEERING, 2020, 5
  • [15] Comparative field experimental investigations of different flat plate solar collectors
    Chen, Guangming
    Doroshenko, Alexander
    Koltun, Paul
    Shestopalov, Kostyantyn
    SOLAR ENERGY, 2015, 115 : 577 - 588
  • [16] Evaluation of a transient test procedure for solar flat-plate collectors
    Mechanical Engineering Department, Faculty of Engineering, Menoufia University, Egypt
    不详
    Energy (Oxford), 12 (979-995):
  • [17] Evaluation of a transient test procedure for solar flat-plate collectors
    Amer, EH
    Nayak, JK
    ENERGY, 1999, 24 (12) : 979 - 995
  • [18] EVALUATION OF THE SUSTAINABILITY OF SOLAR INSTALLATIOSN WITH FLAT PLATE COLLECTORS AND EVACUATED TUBES
    Albizzati, Enrique
    REVISTA INTERNACIONAL DE CONTAMINACION AMBIENTAL, 2016, 32 (03): : 315 - 322
  • [19] THEORETICAL METHOD TO DETERMINE MONTHLY EFFICIENCY OF FLAT-PLATE SOLAR COLLECTORS
    CHOUARD, P
    MICHEL, H
    SIMON, MF
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (06): : 1765 - 1765
  • [20] Solar assisted production of expanded polystyrene with high efficiency flat plate collectors
    Schneider, Elisabeth
    Steinweg, Jan
    Machelett, Lukas