Development of scintillation-light-transmission type phoswich detector for simultaneous alpha- and beta (gamma)-ray counting

被引:0
作者
Yasuda, K [1 ]
Usuda, S [1 ]
Gunji, H [1 ]
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
来源
1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3 | 1999年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of scintillation-light-transmission ZnS(Ag)/NE102A phoswich detector has been developed, in which scintillation light emitted from the phoswich is transmitted through an optical fiber to a photomultiplier tube. By adjusting wavelength of the scintillation light to transmittance region of the optical fiber, the phoswich detector was capable of successfully performing simultaneous counting of alpha- and beta (including gamma)-rays. In addition, the detector has been applied to a dip-type inline monitor, which directly contacts with actinide solution. The detector will be available especially in a narrow and/or isolated space such as glove box and hot cell.
引用
收藏
页码:696 / 699
页数:2
相关论文
共 15 条
[1]   A GENERAL PURPOSE PULSE SHAPE DISCRIMINATING CIRCUIT [J].
KINBARA, S ;
KUMAHARA, T .
NUCLEAR INSTRUMENTS & METHODS, 1969, 70 (02) :173-+
[2]  
KNOLL GF, 1989, RAD DETECTION MEASUR, P221
[3]   MEASUREMENT OF RAYLEIGH BACKSCATTERING IN SINGLE-MODE FIBERS BASED ON COHERENT OFDR EMPLOYING A DFB LASER DIODE [J].
SHIMIZU, K ;
HORIGUCHI, T ;
KOYAMADA, Y .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1991, 3 (11) :1039-1043
[4]   CHARACTERISTICS AND REDUCTION OF COHERENT FADING NOISE IN RAYLEIGH BACKSCATTERING MEASUREMENT FOR OPTICAL FIBERS AND COMPONENTS [J].
SHIMIZU, K ;
HORIGUCHI, T ;
KOYAMADA, Y .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1992, 10 (07) :982-988
[5]  
TERADA H, 1994, IAEASM333, P151
[6]   Phoswich detectors for simultaneous counting of alpha-, beta(gamma)-rays and neutrons [J].
Usuda, S ;
Sakurai, S ;
Yasuda, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2) :193-198
[7]   SIMULTANEOUS COUNTING OF ALPHA-RAYS, BETA-RAYS AND GAMMA-RAYS WITH PHOSWICH DETECTORS [J].
USUDA, S ;
ABE, H ;
MIHARA, A .
JOURNAL OF ALLOYS AND COMPOUNDS, 1994, 213 :437-439
[8]   PHOSWICH DETECTORS COMBINING DOUBLY OR TRIPLY ZNS(AG), NE102A, BGO AND OR NAI(TL) SCINTILLATORS FOR SIMULTANEOUS COUNTING OF ALPHA-RAYS, BETA-RAYS AND GAMMA-RAYS [J].
USUDA, S ;
ABE, H ;
MIHARA, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (03) :540-545
[9]   Simultaneous counting of radiation emitted from actinides with improved phoswich detectors by applying an optical filter [J].
Usuda, S ;
Yasuda, K ;
Sakurai, S .
JOURNAL OF ALLOYS AND COMPOUNDS, 1998, 271 :58-61
[10]  
USUDA S, 1992, J NUCL SCI TECHNOL, V29, P927, DOI [10.1080/18811248.1992.9731613, 10.3327/jnst.29.927]