Retrospective Comparison of Postinsertion Maintenances Between Conventional and 3D Printed Complete Dentures Fabricated in a Predoctoral Clinic

被引:16
作者
Kim, Tae Hyung [1 ]
Huh, Jung Bo [2 ]
Lee, Janet [3 ]
Bae, Eun-Bin [4 ]
Park, Cheryl J. [5 ]
机构
[1] Univ Southern Calif, Removable Prosthodont, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
[2] Pusan Natl Univ, Sch Dent, Inst Dent Res, Inst Translat Dent Sci,Dept Prosthodont, Yangsan, South Korea
[3] Univ Penn, Philadelphia, PA 19104 USA
[4] Pusan Natl Univ, Sch Dent, Inst Translat Dent Sci, Dept Prosthodont, Yangsan, South Korea
[5] Univ Southern Calif, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2021年 / 30卷
关键词
3D Printed denture; digital denture comparison; printed denture performance; ENGINEERED COMPLETE DENTURES; PERFORMANCE; IMPRESSION;
D O I
10.1111/jopr.13322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A retrospective study to analyze the clinical performance of 3D printed complete dentures in edentulous patients compared with conventional complete dentures regarding postinsertion visits and patient reported outcomes. Material and Methods Electronic charts were reviewed to analyze 420 (maxilla 270, mandible 150) heat-polymerized conventional complete dentures (CCD) inserted between July 1, 2015 and June 30, 2016 and 217 (maxilla 130, mandible 86) 3D printed complete dentures (PCD) inserted between July 1, 2017 and June 30, 2018. Number of remakes, number of postinsertion adjustments, type and number of repairs, and patient reported complications were compared between two types of complete dentures. The frequency of denture repair and patient reported complications were analyzed using chi-square of independence test. Results The frequency of pain and visible ulcer lesions in the maxilla was determined to be 46.67% with CCD and 36.15% in PCD (p = 0.047). There was no statistical significance in other items. The majority of esthetic concerns was dissatisfaction with the shape of dentures with CCD (4.67%) and they had statistically significant, less frequent, esthetic problems than PCD (11.63%) (p = 0.047). Conclusions Similar clinical performance was recorded between the two groups, but the overall pain and visible ulcer lesions were less in the printed complete dentures then the conventionally processed dentures. However, the esthetic aspect was better in conventionally processed complete dentures.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 20 条
  • [1] Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes
    Bidra, Avinash S.
    Farrell, Kimberly
    Burnham, David
    Dhingra, Ajay
    Taylor, Thomas D.
    Kuo, Chia-Ling
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 578 - 586
  • [2] COMPUTER-AIDED TECHNOLOGY FOR FABRICATING COMPLETE DENTURES: SYSTEMATIC REVIEW OF HISTORICAL BACKGROUND, CURRENT STATUS, AND FUTURE PERSPECTIVES
    Bidra, Avinash S.
    Taylor, Thomas D.
    Agar, John R.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (06) : 361 - 366
  • [3] Fabricating Complete Dentures with CAD/CAM and RP Technologies
    Bilgin, Mehmet Selim
    Erdem, Ali
    Aglarci, Osman Sami
    Dilber, Erhan
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 576 - 579
  • [4] Ettinger RL., 2018, J PROSTHODONT, DOI [10.1111/jopr12735, DOI 10.1111/JOPR12735]
  • [5] Felton D A, 1996, Dent Clin North Am, V40, P39
  • [6] Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing
    Hwang, Hyun-Ji
    Lee, Sang J.
    Park, Eun-Jin
    Yoon, Hyung-In
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01) : 110 - 117
  • [7] A randomized controlled trial of the different impression methods for the complete denture fabrication: Patient reported outcomes
    Jo, Ayami
    Kanazawa, Manabu
    Sato, Yusuke
    Iwaki, Maiko
    Akiba, Norihisa
    Minakuchi, Shunsuke
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (08) : 989 - 996
  • [8] CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: An in vitro evaluation of trueness
    Kalberer, Nicole
    Mehl, Albert
    Schimmel, Martin
    Mueller, Frauke
    Srinivasan, Murali
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (04) : 637 - 643
  • [9] An update on computer-engineered complete dentures: A systematic review on clinical outcomes
    Kattadiyil, Mathew T.
    AlHelal, Abdulaziz
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) : 478 - 485
  • [10] Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting
    Kattadiyil, Mathew T.
    Jekki, Rami
    Goodacre, Charles J.
    Baba, Nadim Z.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (06) : 818 - 825