Proposed three ratios technique for the interpretation of mineral oil transformers based dissolved gas analysis

被引:52
|
作者
Gouda, Osama E. [1 ]
El-Hoshy, Salah H. [2 ]
L-Tamaly, Hassan H. E. [3 ]
机构
[1] Cairo Univ, Fac Engn, Giza, Egypt
[2] Elect Transmiss Co, Middle Egypt Elect Zone, Al Fayyum, Egypt
[3] Menia Univ, Fac Engn, Al Minya, Egypt
关键词
transformer oil; minerals; chemical analysis; fault diagnosis; power transformer insulation; mineral oil transformer; dissolved gas analysis; incipient fault detection; oil-immersed transformers; Doernenburg ratio; Rogers ratio; IEC ratio; Duval triangle technique; transformer fault diagnosis; gas ratio concentration; interpretation technique; Egyptian Electricity Holding Company; IEC TC10; DGA ratio technique; FAULT-DIAGNOSIS;
D O I
10.1049/iet-gtd.2017.1927
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved gas analysis (DGA) of oil is one of the major diagnostic tools that are used to detect the incipient faults of oil-immersed transformers through the correlation between the dissolved gases content in transformer oil and a particular malfunction. There are several techniques of DGA to interpret the incipient transformer faults such as Doernenburg ratio, Rogers's ratio, IEC ratio and Duval triangle techniques. This study presents a new proposed technique for transformer fault diagnosis using a new three gas ratios concentration of DGA to overcome the conflict that takes place in the traditional interpretation techniques. The accuracy of the proposed diagnosis technique is verified using practical DGA data obtained from 688 samples that have been collected from different transformers of different rating and different lifespan reported by Egyptian Electricity Holding Company, IEC TC10 and related databases surveyed from actual incident cases. The comparison with traditional DGA techniques showed that the proposed DGA ratio technique has good diagnosis accuracy. It is found that the suggested three ratios technique method has 99.86% accuracy as compared with 85.67% for Duval, 75.08% for Doernenburg, 47.34% for IEC and 39% for Rogers when testing 688 cases.
引用
收藏
页码:2650 / 2661
页数:12
相关论文
共 50 条
  • [1] Comparison of Dissolved Gas Interpretation Techniques in Mineral Oil Immersed Transformers
    Balivada, Santhosh Kumar
    Karmakar, Subrata
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 403 - 407
  • [2] A New Graphical Technique for the Interpretation of Dissolved Gas Analysis in Power Transformers
    Mansour, Diaa-Eldin A.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 195 - 198
  • [3] Implementation of a Condition Monitoring Software for Mineral Oil-Immersed Transformers via Dissolved Gas In-Oil Analysis
    Torres, Jorge
    Guerrero, Jose M.
    Leones, Wilson
    Platero, Carlos A.
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [4] Carbon Oxides in the Interpretation of Dissolved Gas Analysis in Transformers and Tap Changers
    Hoehlein-Atanasova, Ivanka
    Frotscher, Rainer
    IEEE ELECTRICAL INSULATION MAGAZINE, 2010, 26 (06) : 22 - 26
  • [5] A Spreadsheet Based Dissolved Gas Analysis Diagnostic Tool For Oil-Filled Transformers
    Mekkayil, Anju
    Pillai, Gobind
    Malcolm, Marc
    2020 55TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2020,
  • [6] Proposed heptagon graph for DGA interpretation of oil transformers
    Gouda, Osama E.
    El-Hoshy, Salah H.
    El-Tamaly, Hassan H.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (02) : 490 - 498
  • [7] Application of Logistic Regression Algorithm in the Interpretation of Dissolved Gas Analysis for Power Transformers
    Almoallem, Yousuf D.
    Taha, Ibrahim B. M.
    Mosaad, Mohamed I.
    Nahma, Lara
    Abu-Siada, Ahmed
    ELECTRONICS, 2021, 10 (10)
  • [8] Dissolved Gas-in-Oil Analysis in Transformers Based on Near-Infrared Photoacoustic Spectroscopy
    Xuefeng Mao
    Xinlei Zhou
    Liang Zhai
    Qingxu Yu
    International Journal of Thermophysics, 2015, 36 : 940 - 946
  • [9] A hybrid tool for detection of incipient faults in transformers based on the dissolved gas analysis of insulating oil
    Morais, Diego
    Rolim, Jacqueline
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 2659 - 2659
  • [10] A hybrid tool for detection of incipient faults in transformers based on the dissolved gas analysis of insulating oil
    Morais, DR
    Rolim, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 673 - 680