Three-Dimensional Facial Anthropometric Analysis With and Without Landmark Labelling: Is There a Real Difference?

被引:5
作者
Gibelli, Daniele [1 ]
Cappella, Annalisa [2 ,3 ]
Bertozzi, Filippo [1 ]
Sala, Davide [1 ]
Sitta, Sara [1 ]
Tasso, Damiano Rosario [1 ]
Tomasi, Francesca [1 ]
Dolci, Claudia [1 ]
Sforza, Chiarella [1 ]
机构
[1] Univ Milan, Dept Biomed Sci Hlth, Lab Funct Anat Stomatognath Syst, LAFAS, Milan, Italy
[2] Policlin San Donato, UO Lab Appl Human Anat, San Donato Milanese, Italy
[3] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
关键词
3D facial assessment; anthropometry; landmark labeling; stereophotogrammetry; TOOTH MOVEMENT; PRECISION; PHOTOGRAMMETRY; ACCURACY; REPRODUCIBILITY; RELIABILITY; FACE; LIP; VALIDATION; MORPHOLOGY;
D O I
10.1097/SCS.0000000000007687
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: The actual role of landmarks labeling before three-dimensional (3D) facial acquisition is still debated. In this study, several measurements were compared among textured labeled (TL), unlabeled (NL), and untextured (NTL) 3D facial models. Materials and Methods: The face of 50 subjects was acquired through stereophotogrammetry. Landmark coordinates were extracted from TL, NL, and NTL facial models, and 33 linear and angular measurements were calculated, together with surface area and volume. Accuracy of measurements among TL, NL, and NTL models was assessed through calculation of relative technical error of measurement (rTEM). The intra- and inter-observer errors for each type of facial model were calculated. Results: Intra- and inter-observer error of measurements increased passing from textured to NTL and NL 3D models. Average rTEMs between TL models, and NTL and NL models were 4.5 +/- 2.6% and 4.7 +/- 2.8%, respectively, almost all measurements being classified as "very good" or "good." Only for orbital height and its inclination, mandibular ramus length, nasal convexity, alar slope angle, and facial divergence, rTEM was classified as "moderate" or "poor." Conclusions: Accuracy and precision of measurements decrease when landmarks are not previously labeled; attention must be taken when measurements have a low magnitude or involve landmarks requiring palpation.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [21] "Utility of Smartphone-based Three-dimensional Surface Imaging for Digital Facial Anthropometry" *
    Hartmann, Robin
    Nieberle, Felix
    Palm, Christoph
    Brebant, Vanessa
    Prantl, Lukas
    Kuehle, Reinald
    Reichert, Torsten E.
    Taxis, Juergen
    Ettl, Tobias
    JPRAS OPEN, 2024, 39 : 330 - 343
  • [22] Accuracy of Smartphone-Based Three-Dimensional Facial Scanning System: A Systematic Review
    Luo, Yuna
    Zhao, Minghao
    Lu, Jianjian
    AESTHETIC PLASTIC SURGERY, 2024, 48 (21) : 4500 - 4512
  • [23] Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: An in-vitro study
    Kuhlman, Deise Caldas
    Almuzian, Mohammed
    Coppini, Christianne
    Alzoubi, Emad Eddin
    JOURNAL OF DENTISTRY, 2023, 135
  • [24] Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems
    Fourie, Zacharias
    Damstra, Janalt
    Gerrits, Peter O.
    Ren, Yijin
    FORENSIC SCIENCE INTERNATIONAL, 2011, 207 (1-3) : 127 - 134
  • [25] Three-dimensional facial anthropometry of unilateral cleft lip infants with a structured light scanning system
    Li, Guanghui
    Wei, Jianhua
    Wang, Xi
    Wu, Guofeng
    Ma, Dandan
    Wang, Bo
    Liu, Yanpu
    Feng, Xinghua
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2013, 66 (08) : 1109 - 1116
  • [26] Comparison of Facial Soft Tissue Measurements on Three-Dimensional Images and Models Obtained With Different Methods
    Germec-Cakan, Derya
    Canter, Halil Ibrahim
    Nur, Burcu
    Arun, Tulin
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (05) : 1393 - 1399
  • [27] Three-dimensional surface models of the facial soft tissues acquired with a low-cost scanner
    Maues, C. P. R.
    Casagrande, M. V. S.
    Almeida, R. C. C.
    Almeida, M. A. O.
    Carvalho, F. A. R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (09) : 1219 - 1225
  • [28] Comparison between landmark and surface-based three-dimensional analyses of facial asymmetry in adults
    Alqattan, M.
    Djordjevic, J.
    Zhurov, A. I.
    Richmond, S.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (01) : 1 - 12
  • [29] Three-Dimensional Assessment of Facial Development in Children With Unilateral Cleft Lip With and Without Alveolar Cleft
    Krimmel, Michael
    Kluba, Susanne
    Breidt, Martin
    Bacher, Margit
    Mueller-Hagedorn, Silvia
    Dietz, Klaus
    Buelthoff, Heinrich
    Reinert, Siegmar
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (01) : 313 - 316
  • [30] Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning
    Modabber, Ali
    Peters, Florian
    Kniha, Kristian
    Goloborodko, Evgeny
    Ghassemi, Alireza
    Lethaus, Bernd
    Hoelzle, Frank
    Moehlhenrich, Stephan Christian
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) : 1719 - 1724