Development and validation of bioanalytical method for simultaneous estimation of ramipril and hydrochlorothiazide in human plasma using liquid chromatography-tandem mass spectrometry

被引:21
作者
Patel, Jatin R. [1 ]
Pethani, Trupesh M. [1 ]
Vachhani, Ashish N. [1 ]
Sheth, Navin R. [1 ]
Dudhrejiya, Ashvin V. [1 ]
机构
[1] Saurashtra Univ, Dept Pharmaceut Sci, Rajkot 360005, Gujarat, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 970卷
关键词
Bioanalytical method; Carbamazepine; Hydrochlorothiazide; LC-MS/MS; Ramipril; ACTIVE METABOLITE RAMIPRILAT; TELMISARTAN;
D O I
10.1016/j.jchromb.2014.08.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study describes a novel liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the simultaneous estimation of ramipril (RAM) and hydrochlorothiazide (HCTZ) in human plasma using liquid-liquid extraction technique. This method made use of electrospray ionization in positive mode for RAM and in negative mode for HCTZ using triple quadrupole mass spectrometry where carbamazepine was used as an internal standard (IS). Analytes were recovered by methyl tertiary butyl ether:dichloromethane (85:15) subsequently separated on an Enable C-18 G column (150 mm x 4.6 mm, 5 mu m) using methanol:0.1% formic acid in water (85:15) as a mobile phase, at a flow rate of 0.5 mL/min. Quantification of RAM, HCTZ and IS was performed using multi-reaction monitoring mode (MRM) where transition of m/z 417.2 -> 234.1 (RAM) and 237.0 -> 194.0 (IS) in positive mode and 296.1 -> 205.0 for HCTZ in negative mode. The calibration curve was linear (r(2) > 0.99) over the concentration range of 2-170 ng/mL for RAM and 8-680 ng/mL for HCTZ. The intra-day and inter-day precisions were <15% and the accuracy was all within +/- 15% (at LLOQ level +/- 20%). Additionally, the LC-MS/MS method was fully validated for all the other parameters such as selectivity, matrix effect, recovery and stability as well. In conclusion, the findings of the present study revealed the selectivity and sensitivity of this method for the simultaneous estimation of RAM and HCTZ in human plasma. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 25 条
[1]   Spectrophotometric determination of ramipril (a novel ACE inhibitor) in dosage forms [J].
Al-Majed, AA ;
Belal, F ;
Al-Warthan, AA .
SPECTROSCOPY LETTERS, 2001, 34 (02) :211-220
[2]  
[Anonymous], GOODMAN GILMANS PHAR
[3]  
[Anonymous], INT J PHARM PHARM SC
[4]  
[Anonymous], AM J ANAL CHEM
[5]   Key elements of bioanalytical method validation for small molecules [J].
Bansal, Surendra ;
DeStefano, Anthony .
AAPS JOURNAL, 2007, 9 (01) :E109-E114
[6]   RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF ATORVASTATIN CALCIUM, LOSARTAN POTASSIUM, ATENOLOL, AND ASPIRIN FROM TABLET DOSAGE FORM AND PLASMA [J].
Bhatia, Neela M. ;
Gurav, Sachin B. ;
Jadhav, Swapnil D. ;
Bhatia, Manish S. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) :428-443
[7]  
Brunton L.L.G., 2007, Goodman and Gilman's Manual of Pharmacology and Therapeutics, V3rd
[8]   Issues in evaluation of bioanalytical method selectivity and drug stability [J].
Dadgar, D ;
Burnett, PE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 14 (1-2) :23-31
[9]   STABILITY-INDICATING ASSAY FOR HYDROCHLOROTHIAZIDE [J].
DANIELS, SL ;
VANDERWIELEN, AJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1981, 70 (02) :211-215
[10]  
FDA, 2001, US DEP HLTH HUM SERV