Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage

被引:45
作者
Lavon, Karin [1 ]
Marom, Gil [1 ]
Bianchi, Matteo [2 ]
Halevi, Rotem [1 ]
Hamdan, Ashraf [3 ]
Morany, Adi [1 ]
Raanani, Ehud [4 ]
Bluestein, Danny [2 ]
Haj-Ali, Rami [1 ,2 ]
机构
[1] Tel Aviv Univ, Sch Mech Engn, Tel Aviv, Israel
[2] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
[3] Rabin Med Ctr, Dept Cardiol, Petah Tiqwa, Israel
[4] Cha Sheba Med Ctr, Dept Cardiothorac Surg, Tel Hashomer, Israel
关键词
Bicuspid aortic valve; Transcatheter aortic valve replacement; Paravalvular leakage; Finite element; Computational fluid dynamics; FINITE-ELEMENT-ANALYSIS; IMPLANTATION; SIMULATION; TAVI; STENOSIS; ROOT; GEOMETRY; IMPACT; COREVALVE; TISSUE;
D O I
10.1007/s11517-019-02012-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Calcific aortic valve disease (CAVD) is characterized by stiffened aortic valve leaflets. Bicuspid aortic valve (BAV) is the most common congenital heart disease. Transcatheter aortic valve replacement (TAVR) is a treatment approach for CAVD where a stent with mounted bioprosthetic valve is deployed on the stenotic valve. Performing TAVR in calcified BAV patients may be associated with post-procedural complications due to the BAV asymmetrical structure. This study aims to develop refined computational models simulating the deployments of Evolut R and PRO TAVR devices in a representative calcified BAV. The paravalvular leakage (PVL) was also calculated by computational fluid dynamics simulations. Computed tomography scan of severely stenotic BAV patient was acquired. The 3D calcium deposits were generated and embedded inside a parametric model of the BAV. Deployments of the Evolut R and PRO inside the calcified BAV were simulated in five bioprosthesis leaflet orientations. The hypothesis of asymmetric and elliptic stent deployment was confirmed. Positioning the bioprosthesis commissures aligned with the native commissures yielded the lowest PVL (15.7 vs. 29.5 mL/beat). The Evolut PRO reduced the PVL in half compared with the Evolut R (15.7 vs. 28.7 mL/beat). The proposed biomechanical computational model could optimize future TAVR treatment in BAV patients.
引用
收藏
页码:2129 / 2143
页数:15
相关论文
共 50 条
[41]   Temporal Trends and Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis [J].
Elbadawi, Ayman ;
Saad, Marwan ;
Elgendy, Islam Y. ;
Barssoum, Kirolos ;
Omer, Mohamed A. ;
Soliman, Ahmed ;
Almahmoud, Mohamed F. ;
Ogunbayo, Gbolahan O. ;
Mentias, Amgad ;
Gilani, Syed ;
Jneid, Hani ;
Aronow, Herbert D. ;
Kleiman, Neil ;
Abbott, J. Dawn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) :1811-1822
[42]   Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement [J].
Zhang, Jiajun ;
Li, Xiaoxing ;
Tian, Rui ;
Zong, Mengzhi ;
Gu, Xinghua ;
Xu, Feng ;
Chen, Yuguo ;
Li, Chuanbao .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12)
[43]   Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies [J].
Reddy, Gautam ;
Wang, Zhen ;
Nishimura, Rick A. ;
Greason, Kevin L. ;
Yoon, Sung-Han ;
Makkar, Raj R. ;
Holmes, David R., Jr. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (05) :975-983
[44]   Transcatheter and Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis [J].
Sanaiha, Yas ;
Hadaya, Joseph E. ;
Tran, Zachary ;
Shemin, Richard J. ;
Benharash, Peyman .
ANNALS OF THORACIC SURGERY, 2023, 115 (03) :611-618
[45]   Effect of Stent Designs on the Paravalvular Regurgitation of Transcatheter Aortic Valve Implantation [J].
Jin, Chang ;
Liu, Rong-Hui ;
Zhong, Sheng-Ping ;
Wang, Li-Zhen ;
Fan, Yu-Bo .
INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS, 2019, 16 (03)
[46]   Clinical Outcomes of Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis [J].
Yoon, Sung-Han ;
Lefevre, Thierry ;
Dvir, Danny ;
Ahn, Jung-Min ;
Arai, Takahide ;
Kim, Young-Hak ;
Watanabe, Yusuke ;
Kao, Paul Hsien-Li ;
Yong, Gerald ;
Yin, Wei-Hsian ;
Lee, Michael Kang-Yin ;
Tay, Edgar L. ;
Kim, Hyo-Soo ;
Chevalier, Bernard ;
Morice, Marie-Claude ;
John, Webb ;
Park, Seung-Jung .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) :B48-B48
[47]   Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve [J].
Salvatore Pasta ;
Stefano Cannata ;
Giovanni Gentile ;
Marzio Di Giuseppe ;
Federica Cosentino ;
Francesca Pasta ;
Valentina Agnese ;
Diego Bellavia ;
Giuseppe M. Raffa ;
Michele Pilato ;
Caterina Gandolfo .
Medical & Biological Engineering & Computing, 2020, 58 :815-829
[48]   Prediction of paravalvular leakage after transcatheter aortic valve implantation [J].
Luigi F. M. Di Martino ;
Wim B. Vletter ;
Ben Ren ;
Carl Schultz ;
Nicolas M. Van Mieghem ;
Osama I. I. Soliman ;
Matteo Di Biase ;
Peter P. de Jaegere ;
Marcel L. Geleijnse .
The International Journal of Cardiovascular Imaging, 2015, 31 :1461-1468
[49]   Transcatheter Aortic Valve Therapy for Bicuspid Aortic Valve Stenosis [J].
Dayawansa, Nalin H. ;
Noaman, Samer ;
Teng, Lung En ;
Htun, Nay Min .
JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)
[50]   Mixed aortic valve disease: association with paravalvular leak and reduced survival after transcatheter aortic valve replacement [J].
Demirel, Caglayan ;
Winter, Max Paul ;
Nitsche, Christian ;
Koschatko, Sophia ;
Jantsch, Charlotte ;
Mascherbauer, Katharina ;
Halavina, Kseniya ;
Heitzinger, Gregor ;
Dona, Carolina ;
Dannenberg, Varius ;
Spinka, Georg ;
Koschutnik, Matthias ;
Andreas, Martin ;
Hengstenberg, Christian ;
Bartko, Philipp E. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (05) :718-726