A new generation of scintillation detectors with identification of events undergoing multiple interactions for gamma-ray imaging and spectroscopy

被引:0
作者
Indovina, Luca [1 ]
Scafe, Raffaele [2 ]
Puccini, Marco [3 ]
Pellegrini, Rosanna [4 ]
Pani, Roberto [5 ]
机构
[1] Univ Cattolica Sacro Cuore, Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Diagnost Imaging Oncol Radiotherapy & Hemato, Largo Agostino Gemelli 8, I-00168 Rome, Italy
[2] C Prof Roberto Pani,Ple Aldo Moro 5, I-00185 Rome, Italy
[3] TERIN ICT, ENEA Italian Natl Agcy New Technol Energy & Susta, Lungotevere Thaon Revel 76, I-00196 Rome, Italy
[4] Sapienza Univ Rome, Dept Mol Med, Ple Aldo Moro, I-00185 Rome, Italy
[5] Sapienza Univ Rome, Dept Med Surg Sci & Biotechnol, Ple Aldo Moro 5, I-00185 Rome, Italy
关键词
Gamma-ray detector; 2-D charge-distribution spreads; Inter-crystal scatter; X-ray escape; SPECT; PET; SYSTEM; ARRAY; PET;
D O I
10.1016/j.apradiso.2022.110189
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The present work deals with a scintillation detector made of a LuYAP:Ce array coupled to a position-sensitive photo-multiplier tube, whose structure is well suitable for SPECT and PET, but also in nuclear physics, astrophysics, astroparticle physics, homeland security, and non-proliferation. The response was investigated under Co-57, Ba-133, Cs-137 gamma-ray irradiation, and with Lu-176 self-activity. The investigation, based on the 2-D charge-profiles spread, provides means for identifying and rejecting multiple-interactions in the crystal-array, like Lu X-ray escape photons, and Compton-scattered ones.
引用
收藏
页数:14
相关论文
共 14 条
[1]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[2]  
Coxeter H.S.M., 1969, INTRO GEOMETRY, Vsecond, P29
[3]   FPGA Based Readout Electronics For Multi Anode PSPMT [J].
Fabbri, Andrea ;
de Notaristefani, Francesco ;
Cencelli, Valentino Orsolini ;
Petulla', Francesco ;
DAbramo, Enrico ;
Pani, Roberto ;
Moschini, Giuliano ;
Navarria, Francesco .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :357-+
[4]   Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution [J].
Levin, CS ;
Hoffman, EJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :781-799
[5]   Fundamental limits of spatial resolution in PET [J].
Moses, William W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S236-S240
[6]   Scintillation arrays characterization for photon emission imaging [J].
Pani, R ;
Scafè, R ;
Pellegrini, R ;
Soluri, A ;
Trotta, G ;
Indovina, L ;
Cinti, MN ;
De Vincentis, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :72-76
[7]  
Pani R., 1994, NUCL INSTRUM METHO A, V348
[8]   A study of response of a LuYAP:Ce array with innovative assembling for PET [J].
Pani, Roberto ;
Cinti, Maria Nerina ;
Scafe, Raffaele ;
Bennati, Paolo ;
Lo Meo, Sergio ;
Preziosi, Enrico ;
Pellegrini, Rosanna ;
De Vincentis, Giuseppe ;
Sacco, Donatella ;
Fabbri, Andrea .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 :82-87
[9]   Effect of inter-crystal compton scatter on efficiency and image noise in small animal PET module [J].
Park, SJ ;
Rogers, WL ;
Clinthorne, NH .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :2272-2277
[10]  
Scafe R., INSTRUMENTS 05 00026, P1