Geometry-independent neutral desorption device for the sensitive EESI-MS detection of explosives on various surfaces

被引:29
作者
Gu, Haiwei [1 ]
Yang, Shuiping [1 ]
Li, Jianqiang [1 ]
Hu, Bin [1 ]
Chen, Huanwen [1 ]
Zhang, Lili [2 ]
Fei, Qiang [2 ]
机构
[1] E China Inst Technol, Dept Appl Chem, Fuzhou 344000, Jiangxi, Peoples R China
[2] Jilin Univ, Coll Chem, Changchun 130023, Jilin Province, Peoples R China
关键词
IONIZATION-MASS-SPECTROMETRY; EXTRACTIVE ELECTROSPRAY-IONIZATION; ASSISTED LASER DESORPTION/IONIZATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION MOBILITY SPECTROMETRY; AMBIENT CONDITIONS; RAPID ANALYSIS; ELECTROCHEMICAL DETECTION; AQUEOUS-SOLUTION; MILK-PRODUCTS;
D O I
10.1039/b921579d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel geometry-independent neutral desorption (GIND) device was successfully developed, which made neutral desorption (ND) sampling easier and more robust on virtually all types of surfaces. The GIND device features a small air-tight enclosure with fixed space between the ND gas emitter, the sample surface, and the sample collector. Besides easy fabrication and convenient use, this configuration facilitates efficient neutral sample transfer and results in high sensitivity by preventing material loss during the ND process. The effects of various operating parameters of the GIND device such as desorption gas composition, surface wetness, gas flow rate, distance between the surface and the gas emitter, internal diameter of the sample outlet, and GIND device material were experimentally investigated. By using the GIND device, trace amounts of typical explosives such as TNT, RDX, HMX, TATP, etc., were successfully sampled from many different kinds of surfaces, including human skin, glove, glass, envelope, plastic, leather, glass, and clothes. GIND-sampled explosives were detected by multiple-stage extractive electrospray ionization mass spectrometry (EESI-MS). Ion/molecule reactions of explosives such as RDX and TATP were implemented in the EESI source for the rapid detection with enhanced sensitivity and specificity. The typical time for a single sample analysis was a few seconds. Successful transportation of the neutral analytes over a distance longer than 10 m was demonstrated, without either significant signal loss or serious delay of signal response. The limit of detection for these explosives in the study was in the range of ca. 59-842 fg (S/N = 3, n = 8) on various surfaces. Acceptable relative standard deviation (RSD) values (ca. 4.6-10.2%, n = 8) were obtained for all the surfaces tested, showing the successful sampling of trace non-volatile explosive compounds (sub-picogram) by the GIND device for the EESI mass spectrometric analysis.
引用
收藏
页码:779 / 788
页数:10
相关论文
共 64 条
  • [51] Explosives detection: A challenge for physical chemistry
    Steinfeld, JI
    Wormhoudt, J
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1998, 49 : 203 - 232
  • [52] Takáts Z, 2005, CHEM COMMUN, P1950, DOI 10.1039/b418697d
  • [53] Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    Takáts, Z
    Wiseman, JM
    Gologan, B
    Cooks, RG
    [J]. SCIENCE, 2004, 306 (5695) : 471 - 473
  • [54] Desorption electrospray ionization in a small pressure-tight enclosure
    Venter, Andre
    Cooks, R. Graham
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (16) : 6398 - 6403
  • [55] A desorption electrospray ionization mass spectrometry study of aging products of diphenylamine stabilizer in double-base propellants
    Venter, Andre
    Ifa, Demian R.
    Cooks, R. Graham
    Poehlein, Sara K.
    Chin, Anton
    Ellison, Dan
    [J]. PROPELLANTS EXPLOSIVES PYROTECHNICS, 2006, 31 (06) : 472 - 476
  • [56] Particle characteristics of trace high explosives: RDX and PETN
    Verkouteren, Jennifer R.
    [J]. JOURNAL OF FORENSIC SCIENCES, 2007, 52 (02) : 335 - 340
  • [57] Selective detection of gas-phase TNT by integrated optical waveguide spectrometry using molecularly imprinted sol-gel sensing films
    Walker, Natalie R.
    Linman, Matthew J.
    Timmers, Margaret M.
    Dean, Stacey L.
    Burkett, Colleen M.
    Lloyd, Julie A.
    Keelor, Joel D.
    Baughman, Brandi M.
    Edmiston, Paul L.
    [J]. ANALYTICA CHIMICA ACTA, 2007, 593 (01) : 82 - 91
  • [58] Sensitive voltammetric sensing of the 2,3-dimethyl-2,3-dinitrobutane (Dmnb) explosive taggant
    Wang, J
    Thongngamdee, S
    Lu, DL
    [J]. ELECTROANALYSIS, 2006, 18 (10) : 971 - 975
  • [59] The use of recently described ionisation techniques for the rapid analysis of some common drugs and samples of biological origin
    Williams, JP
    Patel, VJ
    Holland, R
    Scrivens, JH
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (09) : 1447 - 1456
  • [60] Yang SP, 2009, CHINESE J ANAL CHEM, V37, P691