Geometry-independent neutral desorption device for the sensitive EESI-MS detection of explosives on various surfaces

被引:29
作者
Gu, Haiwei [1 ]
Yang, Shuiping [1 ]
Li, Jianqiang [1 ]
Hu, Bin [1 ]
Chen, Huanwen [1 ]
Zhang, Lili [2 ]
Fei, Qiang [2 ]
机构
[1] E China Inst Technol, Dept Appl Chem, Fuzhou 344000, Jiangxi, Peoples R China
[2] Jilin Univ, Coll Chem, Changchun 130023, Jilin Province, Peoples R China
关键词
IONIZATION-MASS-SPECTROMETRY; EXTRACTIVE ELECTROSPRAY-IONIZATION; ASSISTED LASER DESORPTION/IONIZATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION MOBILITY SPECTROMETRY; AMBIENT CONDITIONS; RAPID ANALYSIS; ELECTROCHEMICAL DETECTION; AQUEOUS-SOLUTION; MILK-PRODUCTS;
D O I
10.1039/b921579d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel geometry-independent neutral desorption (GIND) device was successfully developed, which made neutral desorption (ND) sampling easier and more robust on virtually all types of surfaces. The GIND device features a small air-tight enclosure with fixed space between the ND gas emitter, the sample surface, and the sample collector. Besides easy fabrication and convenient use, this configuration facilitates efficient neutral sample transfer and results in high sensitivity by preventing material loss during the ND process. The effects of various operating parameters of the GIND device such as desorption gas composition, surface wetness, gas flow rate, distance between the surface and the gas emitter, internal diameter of the sample outlet, and GIND device material were experimentally investigated. By using the GIND device, trace amounts of typical explosives such as TNT, RDX, HMX, TATP, etc., were successfully sampled from many different kinds of surfaces, including human skin, glove, glass, envelope, plastic, leather, glass, and clothes. GIND-sampled explosives were detected by multiple-stage extractive electrospray ionization mass spectrometry (EESI-MS). Ion/molecule reactions of explosives such as RDX and TATP were implemented in the EESI source for the rapid detection with enhanced sensitivity and specificity. The typical time for a single sample analysis was a few seconds. Successful transportation of the neutral analytes over a distance longer than 10 m was demonstrated, without either significant signal loss or serious delay of signal response. The limit of detection for these explosives in the study was in the range of ca. 59-842 fg (S/N = 3, n = 8) on various surfaces. Acceptable relative standard deviation (RSD) values (ca. 4.6-10.2%, n = 8) were obtained for all the surfaces tested, showing the successful sampling of trace non-volatile explosive compounds (sub-picogram) by the GIND device for the EESI mass spectrometric analysis.
引用
收藏
页码:779 / 788
页数:10
相关论文
共 64 条
  • [1] Banerjee HN, 1999, YALE J BIOL MED, V72, P1
  • [2] Analysis of forensic soil samples via high-performance liquid chromatography and ion chromatography
    Bommarito, Christopher R.
    Sturdevant, Amanda B.
    Szymanski, David W.
    [J]. JOURNAL OF FORENSIC SCIENCES, 2007, 52 (01) : 24 - 30
  • [3] Instrumentation and characterization of surface desorption atmospheric pressure chemical ionization mass Spectrometry
    Chen, Huan-Wen
    Lai, Jin-Hu
    Zhou, Yu-Fen
    Huan, Yan-Fu
    Li, Jian-Qiang
    Zhang, Xie
    Wang, Zhi-Chang
    Luo, Ming-Biao
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (08) : 1233 - 1240
  • [4] Rapid differentiation of tea products by surface desorption atmospheric pressure chemical ionization mass spectrometry
    Chen, Huanwen
    Liang, Huazheng
    Ding, Jianhua
    Lai, Jinhu
    Huan, Yanfu
    Qiao, Xiaolin
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (25) : 10093 - 10100
  • [5] Neutral desorption sampling of living objects for rapid analysis by extractive electrospray ionization mass spectrometry
    Chen, Huanwen
    Yang, Shuiping
    Wortmann, Arno
    Zenobi, Renato
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (40) : 7591 - 7594
  • [6] Neutral desorption sampling coupled to extractive electrospray ionization mass spectrometry for rapid differentiation of bilosamples by metabolomic fingerprinting
    Chen, Huanwen
    Wortmann, Arno
    Zenobi, Renato
    [J]. JOURNAL OF MASS SPECTROMETRY, 2007, 42 (09): : 1123 - 1135
  • [7] Differentiation of maturity and quality of fruit using noninvasive extractive electrospray ionization quadrupole time-of-flight mass spectrometry
    Chen, Huanwen
    Sun, Yanping
    Wortmann, Arno
    Gu, Haiwei
    Zenobi, Renato
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1447 - 1455
  • [8] Rapid in vivo fingerprinting of nonvolatile compounds in breath by extractive electrospray ionization quadrupole time-of-flight mass spectrometry
    Chen, Huanwen
    Wortmann, Arno
    Zhang, Weihua
    Zenobi, Renato
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (04) : 580 - 583
  • [9] Neutral Desorption Using a Sealed Enclosure to Sample Explosives on Human Skin for Rapid Detection by EESI-MS
    Chen, Huanwen
    Hu, Bin
    Hu, Yan
    Huan, Yanfu
    Zhou, Zhiquan
    Qiao, Xiaofin
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (04) : 719 - 722
  • [10] Neutral desorption sampling of biological surfaces for rapid chemical characterization by extractive electrospray ionization mass spectrometry
    Chen, Huanwen
    Zenobi, Renato
    [J]. NATURE PROTOCOLS, 2008, 3 (09) : 1467 - 1475