Effect of pitch length on the behavior of rotary triple helix root canal instruments

被引:38
|
作者
Diemer, F [1 ]
Calas, P [1 ]
机构
[1] Fac Chirurg Dent Toulouse, Dept Odontol Conservatrice Endodontie, F-31400 Toulouse, France
关键词
D O I
10.1097/01.DON.0000125877.26495.69
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The behavior of nickel-titanium instruments depends largely on the cross-section of the working part. The effect of pitch length was evaluated using two instruments with the same cross-section (triple helix; 0.6% taper). One had a short pitch (0.5 mm at the tip to 0.9 mm at 16 mm at the end of the working part). The other had a long pitch (1.18 mm/2 mm). A dynamometer recorded tensional stress (MHz) and the tendency to screw in (Fz) during simulated canal preparations. Rotational speed was kept constant, and a continuous pecking movement was used. At the end of the preparations, the average Fz was 5.02 N for the short-pitch instrument and 1.47 N for the long-pitch instrument (p < 0.001). The average Mz varied from 0.88 N (short pitch) to 0.35 N (long pitch). Increasing the pitch decreased torsional load sharing and the tendency to screw in.
引用
收藏
页码:716 / 718
页数:3
相关论文
共 50 条
  • [21] THE EFFECT OF DIFFERENT HAND INSTRUMENTS ON THE SHAPE OF THE ROOT-CANAL
    BRISENO, B
    SONNABEND, E
    DETZER, F
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1989, 44 (06): : 446 - 448
  • [22] Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments
    Buerklein, Sebastian
    Donnermeyer, David
    Hentschel, Tim Julian
    Schaefer, Edgar
    MATERIALS, 2021, 14 (05) : 1 - 8
  • [23] Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments
    Paqué, F
    Musch, U
    Hülsmann, M
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 8 - 16
  • [24] Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments
    Pasternak-Junior, Braulio
    de Sousa Neto, Manoel Damido
    Dionisio, Valdeci Carlos
    Pecora, Jesus Djalma
    Silva, Ricardo Gariba
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (01) : 57 - 63
  • [25] Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments
    Gabiana Rodrigues Freitas
    Thais Marchand Ribeiro
    Fabiana Soares Grecca Vilella
    Tiago André Fontoura de Melo
    Clinical Oral Investigations, 2021, 25 : 469 - 475
  • [26] Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments
    Freitas, Gabiana Rodrigues
    Ribeiro, Thais Marchand
    Vilella, Fabiana Soares Grecca
    de Melo, Tiago Andre Fontoura
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (02) : 469 - 475
  • [27] Influence of instrument size and varying electrical resistance of root canal instruments on accuracy of three electronic root canal length measurement devices
    Aggarwal, V.
    Singla, M.
    Bhasin, S. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (05) : 506 - 511
  • [28] The ability of reciprocating glide path instruments to reach the full root canal working length
    Campos, Daniel Souza
    Rodrigues, Evaldo Almeida
    da Silveira Bueno, Carlos Eduardo
    Fontana, Carlos Eduardo
    Nogueira Leal da Silva, Emmanuel Joao
    de Lima, Carolina Oliveira
    De Martin, Alexandre Sigrist
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (03) : 487 - 492
  • [29] The effect of working length and root canal preparation technique on crack development in the apical root canal wall
    Adorno, C. G.
    Yoshioka, T.
    Suda, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) : 321 - 327
  • [30] Efficacy of two rotary NiTi instruments in the removal of gutta-percha during root canal Retreatment
    Saad, Abdulhamied Y.
    Al-Hadlaq, Solaiman M.
    Al-Katheeri, Nasser H.
    JOURNAL OF ENDODONTICS, 2007, 33 (01) : 38 - 41