Test of a Large Volume Calorimeter in KEPRI Tritium Laboratory

被引:0
|
作者
Song, K. M. [1 ]
Ko, B. W. [1 ]
Lee, K. W. [1 ]
Sohn, S. H. [1 ]
机构
[1] Korea Elect Power Res Inst, Nucl Power Lab, Taejon, South Korea
来源
2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING | 2009年
关键词
tritium; calorimeter; tritium accounts; precision;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A tritium assaying and dispensing system has been designed and is being constructed in KEPTL (Korea Electric Power Research Institute, Tritium Laboratory). This facility will be used to supply tritium from WTRF (Wolsong Tritium Removal Facility) to customers for industrial uses, R&D application, ITER operation and other purposes. In order to account the tritium amount loaded in and out this facility, KEPTL purchased a large volume calorimeter from Setaram. This calorimeter is integrated in a dedicated room of the KEPTL in 2008 and the site acceptance tests are completed. The KEPTL calorimeter is a twin cell type and its measuring range is from 0.01 gram of tritium to 60 gram of tritium. The tritium storage beds loaded into the measuring cell of the calorimeter reach a maximum size of 200 mm in diameter and 570 mm in height. The performance test has been successfully completed with a Joule effect cell simulating tritium decay heat. It is demonstrated that the precision of the calorimeter is measured to be less than 0.28% at 50 mW and 0.13% at 10W. Relative error on real tritium test is measured to be 0.06% on 37 TBq of tritium.
引用
收藏
页码:509 / 512
页数:4
相关论文
共 50 条
  • [1] Test of a Large-Volume Calorimeter in KEPRI Tritium Laboratory
    Song, Kyu-Min
    Ko, Byung-Wook
    Lee, Kei-Woo
    Sohn, Soon-Hwan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (03) : 295 - 299
  • [2] A large scale cryopanel test arrangement for tritium pumping
    Day, C
    Brennan, D
    Jensen, HS
    Mack, A
    FUSION ENGINEERING AND DESIGN, 2003, 69 (1-4) : 97 - 102
  • [3] Analytic of tritium-containing gaseous species at the Tritium Laboratory Karlsruhe
    Lässer, R
    Caldwell-Nichols, C
    Dörr, L
    Glugla, M
    Grünhagen, S
    Günther, K
    Penzhorn, RD
    FUSION ENGINEERING AND DESIGN, 2001, 58-59 : 411 - 415
  • [4] Sensitivity of a specially designed calorimeter for absolute evaluation of tritium concentration in water
    Matsuyama, Masao
    Takatsuka, Kenichi
    Hara, Masanori
    FUSION ENGINEERING AND DESIGN, 2010, 85 (10-12) : 2045 - 2048
  • [5] The CLAS electromagnetic calorimeter at large angles
    Anghinolfi, M
    Avakian, H
    Battaglieri, M
    Bianchi, N
    Corvisiero, P
    De Vita, R
    Golovach, E
    Gyuriyan, V
    Mirazita, M
    Mokeev, V
    Muccifora, V
    Osipenko, M
    Polli, E
    Ricco, G
    Ripani, M
    Ronchetti, F
    Rossi, P
    Sapunenko, V
    Taiuti, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (03) : 562 - 570
  • [6] The Calorimeter of the Fermi Large Area Telescope
    Grove, J. Eric
    Johnson, W. Neil
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [7] Test of CAP88-PC's predicted concentrations of tritium in air at Lawrence Livermore National Laboratory
    Peterson, SR
    HEALTH PHYSICS, 2004, 87 (06): : 583 - 595
  • [8] Precision of the Cone Calorimeter and ICAL Test Methods
    Urbas, Joe
    JOURNAL OF TESTING AND EVALUATION, 2011, 39 (06) : 1122 - 1130
  • [9] Precision of the Cone Calorimeter and ICAL Test Methods
    Urbas, Joe
    UNCERTAINTY IN FIRE STANDARDS AND WHAT TO DO ABOUT IT, 2011, 2012, 1541 : 56 - 75
  • [10] The Area Measurements in the Tritium Laboratory Within Nipne Magurele
    Ioan, M. R.
    Bubueanu, G.
    Tuta, C. S.
    FUSION SCIENCE AND TECHNOLOGY, 2020, 76 (03) : 291 - 296