Fault-location Observability Analysis on Power Distribution Systems

被引:5
作者
Xiu, Wanjing [1 ]
Liao, Yuan [1 ]
机构
[1] Univ Kentucky, Dept Elect & Comp Engn, Lexington, KY 40506 USA
关键词
power distribution systems; optimal meter placement; fault-location observability; PLACEMENT; MODEL;
D O I
10.1080/15325008.2014.956953
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most of the fault-location methods developed in the past employed measurements obtained from a limited number of meters installed in a power system. Optimal meter placement in power systems is to make the best use of a limited number of meters available to keep the entire network observable. This article presents the fault-location observability analysis for distribution systems and proposes a novel optimal meter placement algorithm to keep the system observable in terms of fault-location determination. First, the observability of fault location in power systems is defined. Then analysis of the whole system is performed to determine the fewest number of meters needed and the best locations to place those meters to achieve fault-location observability. Case studies based on a 16-bus distribution system have been carried out to illustrate the proposed algorithms.
引用
收藏
页码:1862 / 1871
页数:10
相关论文
共 23 条
[1]   Fault Location of Uncompensated/Series-compensated Lines Using Two-end Synchronized Measurements [J].
Abdelaziz, A. Y. ;
Mekhamer, S. F. ;
Ezzat, M. .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (07) :693-715
[2]   New concept in fault location for overhead distribution systems using superimposed components [J].
Aggarwal, RK ;
Aslan, Y ;
Johns, AT .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1997, 144 (03) :309-316
[3]   Generalized formulation of the optimal monitor placement problem for fault location [J].
Avendano-Mora, M. ;
Milanovic, J. V. .
ELECTRIC POWER SYSTEMS RESEARCH, 2012, 93 :120-126
[4]   A new fault location algorithm using direct circuit analysis for distribution systems [J].
Choi, MS ;
Lee, SJ ;
Lee, DS ;
Jin, BG .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :35-41
[5]   An iterative two-terminal fault-location method based on unsynchronized phasors [J].
Dalcastagne, Andre Luis ;
Noceti Filho, Sidnei ;
Zuern, Hans Helmut ;
Seara, Rui .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) :2318-2329
[6]  
Das R., 2000, 2000 IEEE POW ENG SO
[7]   Applying Dynamic Load Estimation and Distributed-parameter Line Model to Enhance the Accuracy of Impedance-based Fault-location Methods for Power Distribution Networks [J].
Dashti, Rahman ;
Sadeh, Javad .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (14) :1334-1362
[8]   Optimal placement of faulted circuit indicators in power distribution systems [J].
de Almeida, M. C. ;
Costa, F. F. ;
Xavier-de-Souza, S. ;
Santana, F. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (02) :699-706
[9]   Fault diagnosis in distribution networks with distributed generation [J].
El-Zonkoly, A. M. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) :1482-1490
[10]   Improved Fault Location on Distribution Feeders Based on Matching During-Fault Voltage Sags [J].
Fernandes Pereira, Rodrigo Aparecido ;
Wesz da Silva, Luis Gustavo ;
Kezunovic, Mladen ;
Sanches Mantovani, Jose Roberto .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (02) :852-862