Location of Single Phase to Ground Faults in Distribution Networks Based on Synchronous Transients Energy Analysis

被引:134
作者
Wang, Xuewen [1 ]
Zhang, Hengxu [1 ]
Shi, Fang [1 ]
Wu, Qiuwei [2 ,3 ]
Terzija, Vladimir [4 ,5 ]
Xie, Wei [6 ]
Fang, Chen [6 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan 250061, Peoples R China
[2] Tech Univ Denmark, Dept Elect Engn, DK-2800 Lyngby, Denmark
[3] Shandong Univ, Sch Elect Engn, Jinan 250061, Peoples R China
[4] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9P, Lancs, England
[5] Shandong Univ, Sch Elect Engn, Jinan 250061, Peoples R China
[6] State Grid Shanghai Municipal Elect Power Co, Elect Power Res Inst, Shanghai 200437, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Active distribution networks; fault location; neutral non-effectively grounded system; single phase to ground faults; transient zero-sequence current; DISTRIBUTION-SYSTEMS; FEEDER DETECTION; SCHEME;
D O I
10.1109/TSG.2019.2938667
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a result of small fault current, high level of noise and a large penetration of distributed generators (DG), in the neutral non-effectively grounded medium-voltage (MV) distribution networks, it is quite difficult to locate the faulted line section for single phase to ground faults. In this paper, using a technique based on synchronized measurements in distribution networks, a fault location method based on the analysis of the energy of the transient zero-sequence current in the selected frequency band (SFB) is proposed. The equivalent impedance of the distribution network with lateral branches is studied with an equivalent network, and the phase-frequency characteristics of the equivalent impedance are analyzed. The SFB, within which the transient energy of the faulty line section is larger than that of the healthy line sections is determined. A combined fault-section location criterion is proposed and the implementation scheme is illustrated with the distribution level phasor measurement units. Numerical simulations of the IEEE 34 node system and the field experiments of a 10kV distribution network validate the feasibility and effectiveness of the proposed method.
引用
收藏
页码:774 / 785
页数:12
相关论文
共 34 条
  • [1] [Anonymous], [No title captured]
  • [2] [Anonymous], [No title captured]
  • [3] Intelligent Transient Overvoltages Location in Distribution Systems Using Wavelet Packet Decomposition and General Regression Neural Networks
    Chen, Haoyong
    Assala, Pascal Dieu Seul
    Cai, Yongzhi
    Yang, Ping
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2016, 12 (05) : 1726 - 1735
  • [4] Identifying single-phase-to-ground fault feeder in neutral noneffectively grounded distribution system using wavelet transform
    Dong, Xinzhou
    Shi, Shenxing
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1829 - 1837
  • [5] [方毅 Fang Yi], 2018, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V38, P5636
  • [6] A new deal for safety and quality on MV networks
    Griffel, D
    Harmand, Y
    Leitloff, V
    Bergeal, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1428 - 1433
  • [7] Han FL, 2016, Adv Inform Managemen, P1338, DOI 10.1109/IMCEC.2016.7867430
  • [8] Faulty feeder detection by adjusting the compensation degree of arc-suppression coil for distribution network
    Huang, Chun
    Tang, Tao
    Jiang, Yajun
    Hua, Leng
    Hong, Chen
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (04) : 807 - 814
  • [9] A new fault location method for distribution networks using sparse measurements
    Jamali, S.
    Bahmanyar, A.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 81 : 459 - 468
  • [10] Sparse voltage amplitude measurement based fault location in large-scale photovoltaic power plants
    Jia, Ke
    Gu, Chenjie
    Li, Lun
    Xuan, Zhengwen
    Bi, Tianshu
    Thomas, David
    [J]. APPLIED ENERGY, 2018, 211 : 568 - 581