Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer

被引:99
作者
Liu, Wei [1 ]
Schild, Steven E. [1 ]
Chang, Joe Y. [2 ]
Liao, Zhongxing [2 ]
Chang, Yu-Hui [3 ]
Wen, Zhifei [4 ]
Shen, Jiajian [1 ]
Stoker, Joshua B. [1 ]
Ding, Xiaoning [1 ]
Hu, Yanle [1 ]
Sahoo, Narayan [4 ]
Herman, Michael G. [5 ]
Vargas, Carlos [1 ]
Keole, Sameer [1 ]
Wong, William [1 ]
Bues, Martin [1 ]
机构
[1] Mayo Clin Arizona, Dept Radiat Oncol, 5777 E Mayo Blvd, Phoenix, AZ 85054 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Mayo Clin Arizona, Div Hlth Sci Res, Phoenix, AZ 85054 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[5] Mayo Clin, Dept Radiat Oncol, Rochester, MN USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2016年 / 95卷 / 01期
关键词
SCANNED ION-BEAM; BREATHING-SYNCHRONIZED DELIVERY; DEFORMABLE IMAGE REGISTRATION; BODY RADIATION-THERAPY; RESPIRATORY MOTION; RANGE UNCERTAINTIES; PARTICLE THERAPY; DOSE DELIVERY; INTRAFRACTIONAL MOTION; STATISTICAL-ANALYSIS;
D O I
10.1016/j.ijrobp.2015.11.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to compare the impact of uncertainties and interplay on 3-dimensional (3D) and 4D robustly optimized intensity modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods and Materials: IMPT plans were created for 11 nonrandomly selected non-small cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D computed tomography (CT) to irradiate clinical target volume (CTV). Regular fractionation (66 Gy [relative biological effectiveness; RBE] in 33 fractions) was considered. In 4D optimization, the CTV of individual phases received nonuniform doses to achieve a uniform cumulative dose. The root-mean-square dose-volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram (DVH) indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed rank test. Results: 4D robust optimization plans led to smaller AUC for CTV (14.26 vs 18.61, respectively; P=.001), better CTV coverage (Gy [RBE]) (D95% CTV: 60.6 vs 55.2, respectively; P=.001), and better CTV homogeneity (D5%-D95% CTV: 10.3 vs 17.7, resspectively; P=.002) in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage (D95% CTV: 64.5 vs 63.8, respectively; P=.0068), comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions: Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:523 / 533
页数:11
相关论文
共 68 条
  • [1] Is it necessary to plan with safety margins for actively scanned proton therapy?
    Albertini, F.
    Hug, E. B.
    Lomax, A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) : 4399 - 4413
  • [2] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [3] Robust Management of Motion Uncertainty in Intensity-Modulated Radiation Therapy
    Bortfeld, Thomas
    Chan, Timothy C. Y.
    Trofimov, Alexei
    Tsitsiklis, John N.
    [J]. OPERATIONS RESEARCH, 2008, 56 (06) : 1461 - 1473
  • [4] A robust approach to IMRT optimization
    Chan, TCY
    Bortfeld, T
    Tsitsiklis, JN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) : 2567 - 2583
  • [5] Phase 2 Study of High-Dose Proton Therapy With Concurrent Chemotherapy for Unresectable Stage III Nonsmall Cell Lung Cancer
    Chang, Joe Y.
    Komaki, Ritsuko
    Lu, Charles
    Wen, Hong Y.
    Allen, Pamela K.
    Tsao, Anne
    Gillin, Michael
    Mohan, Radhe
    Cox, James D.
    [J]. CANCER, 2011, 117 (20) : 4707 - 4713
  • [6] TOXICITY AND PATTERNS OF FAILURE OF ADAPTIVE/ABLATIVE PROTON THERAPY FOR EARLY-STAGE, MEDICALLY INOPERABLE NON-SMALL CELL LUNG CANCER
    Chang, Joe Y.
    Komaki, Ritsuko
    Wen, Hong Y.
    De Gracia, Beth
    Bluett, Jaques B.
    McAleer, Mary F.
    Swisher, Stephen G.
    Gillin, Michael
    Mohan, Radhe
    Cox, James D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05): : 1350 - 1357
  • [7] Including robustness in multi-criteria optimization for intensity-modulated proton therapy
    Chen, Wei
    Unkelbach, Jan
    Trofimov, Alexei
    Madden, Thomas
    Kooy, Hanne
    Bortfeld, Thomas
    Craft, David
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) : 591 - 608
  • [8] 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung
    Chin, E.
    Loewen, S. K.
    Nichol, A.
    Otto, K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 749 - 770
  • [9] Investigation of a novel algorithm for true 4D-VMAT planning with comparison to tracked, gated and static delivery
    Chin, Erika
    Otto, Karl
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2698 - 2707
  • [10] Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters
    Dowdell, S.
    Grassberger, C.
    Sharp, G. C.
    Paganetti, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) : 4137 - 4156