Endotracheal Tubes: Old and New

被引:66
作者
Haas, Carl F. [1 ]
Eakin, Richard M. [1 ]
Konkle, Mark A. [1 ]
Blank, Ross [2 ]
机构
[1] Univ Michigan Hlth Syst, Ann Arbor, MI 48109 USA
[2] Univ Michigan Hlth Syst, Dept Anesthesiol, Ann Arbor, MI 48109 USA
关键词
endotracheal tube; double-lumen tube; bronchial blocker; RAE tube; laser-resistant tube; Parker Flex-Tip; Hunsaker Mon-Jet tube; biofilm; ventilator-associated pneumonia; subglottic secretion drainage; cuff pressure; microaspiration; polyurethane; tapered cuff; silver-coated endotracheal tube; VENTILATOR-ASSOCIATED PNEUMONIA; SUBGLOTTIC SECRETION DRAINAGE; PAPWORTH-BIVENT-TUBE; TRANSCRANIAL ELECTRICAL-STIMULATION; RANDOMIZED CLINICAL-TRIAL; LOW-PRESSURE CUFFS; MON-JET TUBE; TRACHEAL TUBE; CONTINUOUS ASPIRATION; AIRWAY-OBSTRUCTION;
D O I
10.4187/respcare.02868
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The development and evolution of the endotracheal tube (ETT) have been closely related to advances in surgery and anesthesia. Modifications were made to accomplish many tasks, including minimizing gross aspiration, isolating a lung, providing a clear facial surgical field during general anesthesia, monitoring laryngeal nerve damage during surgery, preventing airway fires during laser surgery, and administering medications. In critical care management, ventilator-associated pneumonia (VAP) is a major concern, as it is associated with increased morbidity, mortality, and cost. It is increasingly appreciated that the ETT itself is a primary causative risk for developing VAP. Unfortunately, contaminated oral and gastric secretions leak down past the inflated ETT cuff into the lung. Bacteria can also grow within the ETT in biofilm and re-enter the lung. Modifications to the ETT that attempt to prevent bacteria from entering around the ETT include maintaining an adequate cuff pressure against the tracheal wall, changing the material and shape of the cuff, and aspirating the secretions that sit above the cuff. Attempts to reduce bacterial entry through the tube include antimicrobial coating of the ETT and mechanically scraping the biofilm from within the ETT. Studies evaluating the effectiveness of these modifications and techniques demonstrate mixed results, and clear recommendations for which modification should be implemented are weak.
引用
收藏
页码:933 / 952
页数:20
相关论文
共 184 条
[11]   Inhibition of bacterial adhesion on PVC endotracheal tubes by RF-oxygen glow discharge, sodium hydroxide and silver nitrate treatments [J].
Balazs, DJ ;
Triandafillu, K ;
Wood, P ;
Chevolot, Y ;
van Delden, C ;
Harms, H ;
Hollenstein, C ;
Mathieu, HJ .
BIOMATERIALS, 2004, 25 (11) :2139-2151
[12]   An In Vitro Study to Assess Determinant Features Associated With Fluid Sealing in the Design of Endotracheal Tube Cuffs and Exerted Tracheal Pressures [J].
Bassi, Gianluigi Li ;
Ranzani, Otavio Tavares ;
Marti, Joan Daniel ;
Giunta, Valeria ;
Luque, Nestor ;
Isetta, Valentina ;
Ferrer, Miquel ;
Farre, Ramon ;
Pimentel, Guilherme Leite ;
Torres, Antoni .
CRITICAL CARE MEDICINE, 2013, 41 (02) :518-526
[13]   Use of the GlideScope for placement of a recurrent Laryngeal nerve monitoring endotracheal tube [J].
Berkow, Lauren ;
Dackiw, Alan P. B. ;
Tufano, Ralph P. .
JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (01) :81-83
[14]   ADJUSTMENT OF INTRACUFF PRESSURE TO PREVENT ASPIRATION [J].
BERNHARD, WN ;
COTTRELL, JE ;
SIVAKUMARAN, C ;
PATEL, K ;
YOST, L ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (04) :363-366
[15]   Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube [J].
Berra, L ;
De Marchi, L ;
Yu, ZX ;
Laquerriere, P ;
Baccarelli, A ;
Kolobow, T .
ANESTHESIOLOGY, 2004, 100 (06) :1446-1456
[16]   Evaluation of continuous aspiration of subglottic secretion in an in vivo study [J].
Berra, L ;
De Marchi, L ;
Panigada, M ;
Yu, ZX ;
Baccarelli, A ;
Kolobow, T .
CRITICAL CARE MEDICINE, 2004, 32 (10) :2071-2078
[17]   Antimicrobial-coated endotracheal tubes: an experimental study [J].
Berra, Lorenzo ;
Curto, Francesco ;
Bassi, Gianluigi Li ;
Laquerriere, Patrice ;
Pitts, Betsey ;
Baccarelli, Andrea ;
Kolobow, Theodor .
INTENSIVE CARE MEDICINE, 2008, 34 (06) :1020-1029
[18]  
Berra L, 2006, INTENS CARE MED, V32, P888, DOI 10.1007/s00134-006-0125-6
[19]   A clinical assessment of the Mucus Shaver: A device to keep the endotracheal tube free from secretions [J].
Berra, Lorenzo ;
Coppadoro, Andrea ;
Bittner, Edward A. ;
Kolobow, Theodor ;
Laquerriere, Patrice ;
Pohlmann, Joshua R. ;
Bramati, Simone ;
Moss, Joel ;
Pesenti, Antonio .
CRITICAL CARE MEDICINE, 2012, 40 (01) :119-124
[20]  
Bhat Anitha G, 2012, J Anaesthesiol Clin Pharmacol, V28, P247, DOI 10.4103/0970-9185.94911