Repair of Partial-Thickness Rotator Cuff Tears: A Biomechanical Analysis of Footprint Contact Pressure and Strength in an Ovine Model

被引:38
作者
Peters, Karin S. [1 ]
Lam, Patrick H. [1 ]
Murrell, George A. C. [1 ]
机构
[1] Univ New S Wales, Orthopaed Res Inst, Sydney, NSW, Australia
关键词
CRUCIATE LIGAMENT RECONSTRUCTION; SUTURE ANCHOR FIXATION; DOUBLE-ROW REPAIR; SUPRASPINATUS TENDON; IMPINGEMENT SYNDROME; ARTHROSCOPIC REPAIR; TRANSTENDON REPAIR; BONE TUNNEL; SINGLE-ROW; ACROMIOPLASTY;
D O I
10.1016/j.arthro.2010.04.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine whether transtendon repair by use of a novel small-diameter knotless anchor showed enhanced mechanical properties compared with tear completion and repair. Methods: Articular-sided partial-thickness tears were created ex vivo in the infraspinatus of 24 ovine shoulders. The specimens were randomized into 4 groups of 6 each: (1) no repair, (2) transtendon repair, (3) completion of tear with tension-band single-row repair, and (4) completion of tear with double-row repair. Footprint contact pressure and ultimate load to failure were measured in each specimen. Results: Technical failure of the transtendon anchors occurred in 3 of 15 shoulders. Transtendon repair (mean +/- SEM, 0.8 +/- 0.1 MPa) and double-row repair (1 +/- 0.09 MPa) showed 3-fold (P < .001) greater footprint contact pressures than tension-band single-row repair (0.3 +/- 0.03 MPa) and no repair (0.3 +/- 0.02 MPa). The ultimate load to failure for transtendon repair (544 +/- 22 N) was more than 3 times greater than that for the double-row repair (157 +/- 23 N) (P < .001) and the single-row repair (116 +/- 11 N) (P < .001). Conclusions: Transtendon repair of partial-thickness tears by use of specifically designed anchors biomechanically outperformed tear completion and repair in an ovine model. Transtendon repair showed the best combination of high footprint contact pressure and high ultimate failure load. However, the high insertion failure rate of these transtendon anchors is of concern. Clinical Relevance: On the basis of the biomechanical data, transtendon repair of partial-thickness rotator cuff tears may be used as an alternative to tear completion and repair, but the specific transtendon anchors used in this study need further evaluation before their clinical use can be recommended.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 43 条
[1]   Arthroscopic acromioplasty - Current status [J].
Altchek, DW ;
Carson, EW .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1997, 28 (02) :157-+
[2]  
ANDRES BM, 2009, ANN M ORTH RES SOC L
[3]  
Andrews J R, 1985, Arthroscopy, V1, P117, DOI 10.1016/S0749-8063(85)80041-4
[4]   Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material [J].
Baums, M. H. ;
Buchhorn, G. H. ;
Spahn, G. ;
Poppendieck, B. ;
Schultz, W. ;
Klinger, H. -M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (11) :1052-1060
[5]   Comparative evaluation of the tendon-bone interface contact pressure in different single- versus double-row suture anchor repair techniques [J].
Baums, Mike H. ;
Spahn, G. ;
Steckel, H. ;
Fischer, A. ;
Schultz, W. ;
Klinger, H. -M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (12) :1466-1472
[6]   Debridement of partial-thickness tears of the rotator cuff without acromioplasty - Long-term follow-up and review of the literature [J].
Budoff, JE ;
Nirschl, RP ;
Guidi, EJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :733-748
[7]   Arthroscopic rotator cuff debridement without decompression for the treatment of tendinosis [J].
Budoff, JE ;
Rodin, D ;
Ochiai, D ;
Nirschl, RP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (09) :1081-1089
[8]   The partial-thickness rotator cuff tear: Is acromioplasty without repair sufficient? [J].
Cordasco, FA ;
Backer, M ;
Craig, EV ;
Klein, D ;
Warren, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (02) :257-260
[9]   Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure [J].
Cummins, CA ;
Appleyard, RC ;
Strickland, S ;
Haen, PS ;
Chen, SY ;
Murrell, GAC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (10) :1236-1241
[10]  
ELLMAN H, 1990, CLIN ORTHOP RELAT R, P64