Study on a new fault phase selector in interconnection line with wind turbine based on doubly-fed induction generator's wind farm

被引:3
作者
Xiao, Fan [1 ]
Liu, Dan [1 ]
Ji, Xiaotong [1 ]
Cao, Kan [1 ]
Xiong, Ping [1 ]
机构
[1] Hubei Elect Power Co Ltd, Elect Power Res Inst, Wuhan 430077, Peoples R China
关键词
Wind farm; DFIGWT; Phase selector; Phase voltage; Superimposed; COORDINATED CONTROL; DYNAMIC-BEHAVIOR; DFIG; PROTECTION; CIRCUIT;
D O I
10.1016/j.egyr.2022.05.058
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The fault current characteristics of wind turbine based on doubly fed induction generator (DFIGWT) is complicated. The conventional superimposed phase selectors cannot meet the requirements of phase selection in the interconnection line based on DFIGWT's wind farm. In this paper, according to the low voltage ride-through strategy of DFIGWTs, the shortcomings of traditional superimposed phase selector are analyzed. Then, a new fault phase selector is proposed based on the amplitude ratio between superimposed phase voltage and superimposed phase-to-phase voltage. According to the proportional relationship between the superimposed phase voltage and superimposed phase-to-phase voltage in the interconnection line with DFIGWT-based wind farm, the fault phase selection coefficients are proposed. Based on the proposed fault phase selection coefficients, the fault phases under different fault conditions can be identified. Finally, the effectiveness and reliability of the proposed fault phase selector are validated by simulation. Test results show that the proposed method is not affected by the LVRT control strategies and can meet the phase selection requirements of new energy sources under different LVRT strategies conditions. (C) 2022 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:412 / 425
页数:14
相关论文
共 27 条
[11]   Feed-Forward Transient Current Control for Low-Voltage Ride-Through Enhancement of DFIG Wind Turbines [J].
Liang, Jiaqi ;
Qiao, Wei ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) :836-843
[12]   Dynamic behavior of the doubly fed induction generator during three-phase voltage dips [J].
Lopez, Jesus ;
Sanchis, Pablo ;
Roboam, Xavier ;
Marroyo, Luis .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) :709-717
[13]   Coordinated Direct Power Control of DFIG System Without Phase-Locked Loop Under Unbalanced Grid Voltage Conditions [J].
Nian, Heng ;
Cheng, Peng ;
Zhu, Z. Q. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) :2905-2918
[14]   Dynamic behavior of the excitation circuit of a doubly-fed induction generator under a symmetrical voltage drop [J].
Ouyang, Jinxin ;
Xiong, Xiaofu .
RENEWABLE ENERGY, 2014, 71 :629-638
[15]  
Peng Donghu, 2018, RENEW ENERGY RESOUR, V32, P418
[16]   Adaptive distance relay setting for lines connecting wind farms [J].
Pradhan, A. K. ;
Joos, Geza .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :206-213
[17]  
State Grid, 2011, 199632011 GBT
[18]   A review of grid code technical requirements for wind farms [J].
Tsili, M. ;
Papathanassiou, S. .
IET RENEWABLE POWER GENERATION, 2009, 3 (03) :308-332
[19]  
Wang Chenxing, 2016, AUTOM ELECT POWER SY, V1, P89
[20]   Fault Current Characteristics of the DFIG under Asymmetrical Fault Conditions [J].
Xiao, Fan ;
Zhang, Zhe ;
Yin, Xianggen .
ENERGIES, 2015, 8 (10) :10971-10992