High-resolution three-dimensional optical coherence tomography imaging of kidney microanatomy ex vivo

被引:52
作者
Chen, Yu
Andrews, Peter M.
Aguirre, Aaron D.
Schmitt, Joseph M.
Fujimoto, James G.
机构
[1] MIT, Dept Elect Engn & Comp Sci, Res Lab Elect, Cambridge, MA 02139 USA
[2] Georgetown Univ, Med Ctr, Dept Biochem Mol & Cellular Biol, Washington, DC 20007 USA
[3] LightLab Imaging, Westford, MA 01886 USA
关键词
kidney; renal pathology; ischemia; mercury toxicity; transplantation; optical coherence tomography (OCT); three-dimensional (3-D) imaging;
D O I
10.1117/1.2736421
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined with small-diameter catheters or needle probes, OCT offers a practical tool for the minimally invasive imaging of living tissue morphology. We evaluate the ability of OCT to image normal kidneys and discriminate pathological changes in kidney structure. Both control and experimental preserved rat kidneys were examined ex vivo by using a high-resolution OCT imaging system equipped with a laser light source at 1.3-mu m wavelength. This system has a resolution of 3.3 mu m (depth) by 6 mu m (transverse). OCT imaging produced cross-sectional and en face images that revealed the sizes and shapes of the uriniferous tubules and renal corpuscles. OCT data revealed significant changes in the uriniferous tubules of kidneys preserved following an ischemic or toxic (i.e., mercuric chloride) insult. OCT data was also rendered to produce informative three-dimensional (3-D) images of uriniferous tubules and renal corpuscles. The foregoing observations suggest that OCT can be a useful non-excisional, real-time modality for imaging pathological changes in donor kidney morphology prior to transplantation. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:7
相关论文
共 40 条
[1]   SCANNING ELECTRON-MICROSCOPIC STUDY OF NEPHRON [J].
ANDREWS, PM ;
PORTER, KR .
AMERICAN JOURNAL OF ANATOMY, 1974, 140 (01) :81-115
[2]  
ANDREWS PM, 1983, LAB INVEST, V49, P87
[3]   HIGH DIETARY-PROTEIN REGIMENS PROVIDE SIGNIFICANT PROTECTION FROM MERCURY NEPHROTOXICITY IN RATS [J].
ANDREWS, PM ;
CHUNG, EM .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1990, 105 (02) :288-304
[4]  
ANDREWS PM, 1982, LAB INVEST, V46, P100
[5]   A TECHNIQUE TO REDUCE FIXATION ARTIFACTS TO KIDNEY PROXIMAL TUBULES [J].
ANDREWS, PM ;
COFFEY, AK .
KIDNEY INTERNATIONAL, 1984, 25 (06) :964-968
[6]  
ANDREWS PM, 1983, NEPHRON, V91, P148
[7]   High-resolution optical coherence tomography-guided laser ablation of surgical tissue [J].
Boppart, SA ;
Herrmann, J ;
Pitris, C ;
Stamper, DL ;
Brezinski, ME ;
Fujimoto, JG .
JOURNAL OF SURGICAL RESEARCH, 1999, 82 (02) :275-284
[8]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[9]   Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound [J].
Brezinski, ME ;
Tearney, GJ ;
Weissman, NJ ;
Boppart, SA ;
Bouma, BE ;
Hee, MR ;
Weyman, AE ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
HEART, 1997, 77 (05) :397-403
[10]   Novel virtual biopsy of the kidney with near infrared, reflectance confocal microscopy:: A pilot study in vivo and ex vivo [J].
Campo-Ruiz, V ;
Lauwers, GY ;
Anderson, RR ;
Delgado-Baeza, E ;
González, S .
JOURNAL OF UROLOGY, 2006, 175 (01) :327-336