Femtosecond Laser Cutting of Endothelial Grafts: Comparison of Endothelial and Epithelial Applanation

被引:6
作者
Bernard, Aurelien [1 ]
He, Zhiguo [1 ]
Gauthier, Anne Sophie [1 ,2 ]
Trone, Marie Caroline [1 ,3 ]
Baubeau, Emmanuel [4 ]
Forest, Fabien [1 ,5 ]
Dumollard, Jean Marc [1 ,5 ]
Peoc'h, Michel [1 ,5 ]
Thuret, Gilles [1 ,2 ,6 ]
Gain, Philippe [1 ,3 ]
机构
[1] Univ St Etienne, Fac Med, Corneal Graft Biol Engn Imaging Lab, EA2521,SFR143, F-42023 St Etienne 02, France
[2] Univ Hosp, Dept Ophthalmol, Besancon, France
[3] Univ Hosp, Dept Ophthalmol, St Etienne, France
[4] Manutech Ultrafast Surfacing Design, Pole Opt Rhone Alpes, St Etienne, France
[5] Univ Hosp, Dept Pathol, St Etienne, France
[6] Inst Univ France, Paris, France
关键词
cornea; human; microkeratome; femtosecond laser; endothelium; graft; quality; viability; applanation; POSTERIOR LAMELLAR DISCS; IMAGE-ANALYSIS; KERATOPLASTY; MICROKERATOME; INTRALASE; DONOR; VIABILITY; QUALITY;
D O I
10.1097/ICO.0000000000000314
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Stromal surface quality of endothelial lamellae cut for endothelial keratoplasty with a femtosecond laser (FSL) with epithelial applanation remains disappointing. Applanation of the endothelial side of the cornea, mounted inverted on an artificial chamber, has therefore been proposed to improve cut quality. We compared lamellar quality after FSL cutting using epithelial versus endothelial applanation. Method: Lamellae were cut with an FSL from organ-cultured corneas. After randomization, 7 were cut with epithelial applanation and 7 with endothelial applanation. Lamellae of 50-, 75-, and 100-mu m thickness were targeted. Thickness was measured by optical coherence tomography before and immediately after cutting. Viable endothelial cell density was quantified immediately after cutting using triple labeling with Hoechst/ethidium/calcein-AM coupled with image analysis with ImageJ. The stromal surface was evaluated by 9 masked observers using semiquantitative scoring of scanning electronic microscopy images. Histology of 2 samples was also analyzed before lamellar detachment. Results: Precision (difference in target/actual thickness) and thickness regularity [coefficient of variation (CV) of 10 measurements] were significantly better with endothelial applanation (precision: 18 mu m; range, 10-30; CV: 11%; range, 8-12) than with epithelial applanation (precision: 84 mu m; range, 54-107; P = 0.002; CV: 24%; range, 13-47; P = 0.001). Endothelial applanation provided thinner lamellae. However, viable endothelial cell density was significantly lower after endothelial applanation (1183 cells/mm(2); range, 787-1725 versus 1688 cells/mm2; range, 1288-2025; P = 0.018). Conclusions: FSL cutting of endothelial lamellae using endothelial applanation provides thinner more regular grafts with more predictable thickness than with conventional epithelial applanation but strongly reduces the pool of viable endothelial cells.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 29 条
[1]   Endothelial Morphometry by Image Analysis of Corneas Organ Cultured at 31°C [J].
Acquart, Sophie ;
Gain, Philippe ;
Zhao, Min ;
Gavet, Yann ;
Defreyn, Alexandre ;
Piselli, Simone ;
Garraud, Olivier ;
Thuret, Gilles .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (03) :1356-1364
[2]   Anterior Segment Biometry Using Spectral-Domain Optical Coherence Tomography [J].
Aptel, Florent ;
Chiquet, Christophe ;
Gimbert, Aurelie ;
Romanet, Jean-Paul ;
Thuret, Gilles ;
Gain, Philippe ;
Campolmi, Nelly .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (05) :354-+
[3]  
Baikoff G., 2009, TECH OPHTHALMOL, V7, P89
[4]   Study of Stromal Femtosecond Laser Ablation for Deep Corneal Cut Optimization [J].
Bernard, A. ;
Audouard, E. ;
Thuret, G. ;
Peoc'h, M. ;
Dumollard, J-M. ;
Granier, J. ;
Moine, B. ;
Soder, H. ;
Gain, P. .
JOURNAL OF LASER MICRO NANOENGINEERING, 2012, 7 (03) :351-354
[5]   CorneaJ: An ImageJ Plugin for Semi-Automated Measurement of Corneal Endothelial Cell Viability [J].
Bernard, Aurelien ;
Campolmi, Nelly ;
He, Zhiguo ;
Binh Minh Ha Thi ;
Piselli, Simone ;
Forest, Fabien ;
Dumollard, Jean-Marc ;
Peoc'h, Michel ;
Acquart, Sophie ;
Gain, Philippe ;
Thuret, Gilles .
CORNEA, 2014, 33 (06) :604-609
[6]   Corneal endothelial viability after femtosecond laser preparation of posterior lamellar discs for Descemet-stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Cleutjens, Jack P. M. ;
van Suylen, Robert J. ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
CORNEA, 2007, 26 (09) :1118-1122
[7]   Femtosecond-laser-assisted Descemet's stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :152-155
[8]   Efficacy and Safety of Femtosecond Laser-Assisted Corneal Endothelial Keratoplasty: A Randomized Multicenter Clinical Trial [J].
Cheng, Yanny Y. Y. ;
Schouten, Jan S. A. G. ;
Tahzib, Nayyirih G. ;
Wijdh, Robert-Jan ;
Pels, Elisabeth ;
van Cleynenbreugel, Hugo ;
Eggink, Catharina A. ;
Rijneveld, Wilhelmina J. ;
Nuijts, Rudy M. M. A. .
TRANSPLANTATION, 2009, 88 (11) :1294-1302
[9]   Histologic Evaluation of Human Posterior Lamellar Discs for Femtosecond Laser Descemet's Stripping Endothelial Keratoplasty [J].
Cheng, Yanny Y. Y. ;
Kang, Shin J. ;
Grossniklaus, Hans E. ;
Pels, Elisabeth ;
Duimel, Hans J. Q. ;
Frederik, Peter M. ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
CORNEA, 2009, 28 (01) :73-79
[10]   Comparison of two semiautomated methods for evaluating endothelial cells of eye bank corneas [J].
Deb-Joardar, Nilanjana ;
Thuret, Gilles ;
Zhao, Min ;
Acquart, Sophie ;
Peoc'h, Michel ;
Garraud, Olivier ;
Gain, Philippe .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3077-3082