Feasibility and Safety of Contrast-Enhanced Ultrasound of the Neonatal Brain: A Prospective Study Using MRI as the Reference Standard

被引:10
作者
Squires, Judy H. [1 ,2 ]
Beluk, Nancy H. [1 ]
Lee, Vince K. [1 ]
Yanowitz, Toby D. [3 ]
Gumus, Serter [1 ,2 ]
Subramanian, Subramanian [1 ,2 ]
Panigrahy, Ashok [1 ,2 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA 15213 USA
[2] UPMC Childrens Hosp Pittsburgh, Dept Pediat Radiol, 4401 Penn Ave,2nd FI Radiol, Pittsburgh, PA 15224 USA
[3] Univ Pittsburgh, Magee Womens Hosp, Dept Neonatol, Sch Med, Pittsburgh, PA USA
关键词
contrast-enhanced ultrasound; infant; neonate; neuroimaging; transfontanelle ultrasound; CRANIAL ULTRASONOGRAPHY; INFANTS;
D O I
10.2214/AJR.21.26274
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. MRI is the reference standard for neonatal brain imaging, but it is expensive, time-consuming, potentially limited by availability and accessibility, and contraindicated in some patients. Transfontanelle neonatal head ultrasound is an excellent alternative but may be less sensitive and specific than MRI. Contrast-enhanced ultrasound (CEUS) has the potential to improve the capabilities of ultrasound. OBJECTIVE. The purpose of this study is to prospectively evaluate the feasibility, safety, and diagnostic performance of transfontanelle neonatal brain CEUS, with MRI used as the reference standard. METHODS. Neonates in the institutional neonatal ICU who were undergoing MRI as part of their clinical care were prospectively recruited to undergo portable brain ultrasound and CEUS for research purposes. Brain ultrasound and CEUS were performed portably without moving the patient from the isolette or crib in the neonatal ICU. Adverse events were recorded. Two radiologists independently evaluated ultrasound and CEUS images for abnormalities and then reached consensus regarding discrepancies. A separate radiologist reviewed MRI examinations. Sensitivity, specificity, and interreader agreement were evaluated, with MRI used as the reference. Qualitative post hoc image review was performed. RESULTS. Twenty-six neonates (nine boys and 17 girls; mean [+/- SD] age, 15.2 +/- 14.0 days) were included. No significant alteration in patient vital signs or adverse reaction to the ultrasound contrast agent (UCA) occurred. The mean duration of the examination was significantly shorter for combined ultrasound and CEUS than for MRI (21.1 +/- 4.7 vs 74.2 +/- 34.8 minutes; p < .001). Interrater agreement for any abnormality was almost perfect for both ultrasound and CEUS (kappa = 0.92 and 0.85, respectively). Sensitivity for any abnormality was 86.7% for ultrasound and 93.3% for CEUS; specificity was 100.0% for both. CEUS had sensitivity of 87.5% for acute or subacute ischemia and 100.0% for chronic ischemia; its specificity was 100.0% for acute or subacute ischemia and chronic ischemia. For both ultrasound and CEUS, sensitivity for subdural and intraparenchymal hemorrhage was poor (22.2-50.0%). On CEUS but not on MRI, post hoc review showed a case of postischemic hyperperfusion, which was confirmed by subsequently performed contrast-enhanced CT. CONCLUSION. The use of portable brain CEUS in neonates is feasible, safe, and more rapid than MRI. CLINICAL IMPACT. The potential diagnostic utility of brain neonatal CEUS relative to conventional ultrasound, particularly for ischemia, warrants further investigation.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [31] Bipolar radiofrequency ablation for liver tumors: comparison of contrast-enhanced ultrasound with contrast-enhanced MRI/CT in the posttreatment imaging evaluation
    Bo, Xiao-Wan
    Xu, Hui-Xiong
    Sun, Li-Ping
    Zheng, Shu-Guang
    Guo, Le-Hang
    Lu, Feng
    Wu, Jian
    Xu, Xiao-Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (09): : 6108 - 6116
  • [32] Introduction to contrast-enhanced ultrasound of the brain in neonates and infants: current understanding and future potential
    Hwang, Misun
    PEDIATRIC RADIOLOGY, 2019, 49 (02) : 254 - 262
  • [33] Introduction to contrast-enhanced ultrasound of the brain in neonates and infants: current understanding and future potential
    Misun Hwang
    Pediatric Radiology, 2019, 49 : 254 - 262
  • [34] Dynamic Contrast-enhanced MR Lymphangiography: Feasibility Study in Swine
    Dori, Yoav
    Zviman, Menekhem M.
    Itkin, Maxim
    RADIOLOGY, 2014, 273 (02) : 410 - 416
  • [35] Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
    Machado, Priscilla
    Tan, Allison
    Forsberg, Flemming
    Gonsalves, Carin F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03) : 394 - 398
  • [36] CONTRAST-ENHANCED ULTRASOUND USING PERFLUOROBUTANE-CONTAINING MICROBUBBLES IN THE ASSESSMENT OF LIVER ALLOGRAFT DAMAGE: AN EXPLORATORY PROSPECTIVE STUDY
    Joo, Ijin
    Lee, Jae Young
    Lee, Dong Ho
    Jeon, Ju Hyeon
    Kim, Hyeyoung
    Yi, Nam-Joon
    Lee, Kwang-Woong
    Suh, Kyung-Suk
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (03) : 621 - 628
  • [37] Intraoperative Contrast-Enhanced Ultrasound Imaging of Femoral Head Perfusion in Developmental Dysplasia of the Hip: A Feasibility Study
    Back, Susan J.
    Chauvin, Nancy A.
    Ntoulia, Aikaterini
    Ho-Fung, Victor M.
    Toro, Juan S. Calle
    Sridharan, Anush
    Morgan, Trudy A.
    Kozak, Brandi
    Darge, Kassa
    Sankar, Wudbhav N.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (02) : 247 - 257
  • [38] CT, MRI and contrast-enhanced ultrasound features of mucinous cystic neoplasm of the liver
    Rius, Emily
    Dautry, Raphael
    Tzedakis, Stylianos
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 79 - 80
  • [39] Diagnostic efficacy of contrast-enhanced ultrasound, dynamic contrast-enhanced MRI combined with tumor markers AFP and DCP for primary hepatocellular carcinoma
    Guo, Xiaohai
    Tian, Changqing
    Liu, Gaili
    Mi, Xiufang
    Gao, Dezhen
    BIOTECHNOLOGY AND GENETIC ENGINEERING REVIEWS, 2024, 40 (01) : 623 - 637
  • [40] Microcirculation of subepithelial gastric tumors using contrast-enhanced ultrasound
    Stock, K.
    von Weyhern, C. Hann
    Slotta-Huspenina, J.
    Burian, M.
    Clevert, D. A.
    Meining, A.
    Prinz, C.
    Pachmann, C.
    Holzapfel, K.
    Schmid, R. M.
    Lersch, C.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2010, 45 (2-4) : 225 - 232