Feasibility and Safety of Contrast-Enhanced Ultrasound of the Neonatal Brain: A Prospective Study Using MRI as the Reference Standard

被引:10
作者
Squires, Judy H. [1 ,2 ]
Beluk, Nancy H. [1 ]
Lee, Vince K. [1 ]
Yanowitz, Toby D. [3 ]
Gumus, Serter [1 ,2 ]
Subramanian, Subramanian [1 ,2 ]
Panigrahy, Ashok [1 ,2 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA 15213 USA
[2] UPMC Childrens Hosp Pittsburgh, Dept Pediat Radiol, 4401 Penn Ave,2nd FI Radiol, Pittsburgh, PA 15224 USA
[3] Univ Pittsburgh, Magee Womens Hosp, Dept Neonatol, Sch Med, Pittsburgh, PA USA
关键词
contrast-enhanced ultrasound; infant; neonate; neuroimaging; transfontanelle ultrasound; CRANIAL ULTRASONOGRAPHY; INFANTS;
D O I
10.2214/AJR.21.26274
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. MRI is the reference standard for neonatal brain imaging, but it is expensive, time-consuming, potentially limited by availability and accessibility, and contraindicated in some patients. Transfontanelle neonatal head ultrasound is an excellent alternative but may be less sensitive and specific than MRI. Contrast-enhanced ultrasound (CEUS) has the potential to improve the capabilities of ultrasound. OBJECTIVE. The purpose of this study is to prospectively evaluate the feasibility, safety, and diagnostic performance of transfontanelle neonatal brain CEUS, with MRI used as the reference standard. METHODS. Neonates in the institutional neonatal ICU who were undergoing MRI as part of their clinical care were prospectively recruited to undergo portable brain ultrasound and CEUS for research purposes. Brain ultrasound and CEUS were performed portably without moving the patient from the isolette or crib in the neonatal ICU. Adverse events were recorded. Two radiologists independently evaluated ultrasound and CEUS images for abnormalities and then reached consensus regarding discrepancies. A separate radiologist reviewed MRI examinations. Sensitivity, specificity, and interreader agreement were evaluated, with MRI used as the reference. Qualitative post hoc image review was performed. RESULTS. Twenty-six neonates (nine boys and 17 girls; mean [+/- SD] age, 15.2 +/- 14.0 days) were included. No significant alteration in patient vital signs or adverse reaction to the ultrasound contrast agent (UCA) occurred. The mean duration of the examination was significantly shorter for combined ultrasound and CEUS than for MRI (21.1 +/- 4.7 vs 74.2 +/- 34.8 minutes; p < .001). Interrater agreement for any abnormality was almost perfect for both ultrasound and CEUS (kappa = 0.92 and 0.85, respectively). Sensitivity for any abnormality was 86.7% for ultrasound and 93.3% for CEUS; specificity was 100.0% for both. CEUS had sensitivity of 87.5% for acute or subacute ischemia and 100.0% for chronic ischemia; its specificity was 100.0% for acute or subacute ischemia and chronic ischemia. For both ultrasound and CEUS, sensitivity for subdural and intraparenchymal hemorrhage was poor (22.2-50.0%). On CEUS but not on MRI, post hoc review showed a case of postischemic hyperperfusion, which was confirmed by subsequently performed contrast-enhanced CT. CONCLUSION. The use of portable brain CEUS in neonates is feasible, safe, and more rapid than MRI. CLINICAL IMPACT. The potential diagnostic utility of brain neonatal CEUS relative to conventional ultrasound, particularly for ischemia, warrants further investigation.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [1] Contrast-enhanced ultrasound of the neonatal brain
    Gumus, Memduha
    Oommen, Kevin C.
    Squires, Judy H.
    PEDIATRIC RADIOLOGY, 2022, 52 (04) : 837 - 846
  • [2] Contrast-enhanced ultrasound of the neonatal brain
    Memduha Gumus
    Kevin C. Oommen
    Judy H. Squires
    Pediatric Radiology, 2022, 52 : 837 - 846
  • [3] Contrast-Enhanced Ultrasound and Elastography Imaging of the Neonatal Brain: A Review
    Bailey, Christopher
    Huisman, Thierry A. G. M.
    de Jong, Robert M.
    Hwang, Misun
    JOURNAL OF NEUROIMAGING, 2017, 27 (05) : 437 - 441
  • [4] The Use of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of the Neonatal Brain
    Plut, Domen
    Prutki, Maja
    Slak, Peter
    CHILDREN-BASEL, 2023, 10 (08):
  • [5] Contrast-enhanced ultrasound of the pediatric brain
    Hwang, Misun
    Barnewolt, Carol E.
    Juengert, Joerg
    Prada, Francesco
    Sridharan, Anush
    Didier, Ryne A.
    PEDIATRIC RADIOLOGY, 2021, 51 (12) : 2270 - 2283
  • [6] Contrast-enhanced ultrasound of the pediatric brain
    Misun Hwang
    Carol E. Barnewolt
    Jörg Jüngert
    Francesco Prada
    Anush Sridharan
    Ryne A. Didier
    Pediatric Radiology, 2021, 51 : 2270 - 2283
  • [7] USE OF CONTRAST-ENHANCED ULTRASOUND IN THE ASSESSMENT OF UTERINE FIBROIDS: A FEASIBILITY STUDY
    Stoelinga, Barbara
    Dooper, Anniek M. C.
    Juffermans, Lynda J. M.
    Postema, ArnoudW.
    Wijkstra, Hessel
    Brolmann, Hans A. M.
    Huirne, Judith A. F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08) : 1901 - 1909
  • [8] Comparing Sonazoid contrast-enhanced ultrasound to contrast-enhanced CT and MRI for differentially diagnosing renal lesions: a prospective multicenter study (vol 42, 302, 2024)
    Zhao, Qin-xian
    Wu, Chong
    Tan, Shuilian
    Yang, Yongfeng
    Cui, Xin-Wu
    Dietrich, Christoph F.
    Yang, Bin
    Xu, Chao-li
    Gao, Yong-yan
    Xie, Ming-xing
    Wu, Chang-jun
    Liu, Li-ping
    Wang, Xing-hua
    Ling-hu, Run-ze
    Wang, Ning
    Wang, Fei
    Wang, Xiu-li
    Liu, Guo-yan
    Yu, Xiao-ling
    Yu, Jie
    Cheng, Zhi-gang
    Liang, Ping
    WORLD JOURNAL OF UROLOGY, 2024, 42 (01)
  • [9] Application of the CT/MRI LI-RADS Treatment Response Algorithm to Contrast-Enhanced Ultrasound: A Feasibility Study
    Ruan, Si-Min
    Cheng, Mei-Qing
    Huang, Hui
    Hu, Hang-Tong
    Li, Wei
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    Lin, Man-Xia
    Wang, Wei
    JOURNAL OF HEPATOCELLULAR CARCINOMA, 2022, 9 : 437 - 451
  • [10] The feasibility of contrast-enhanced ultrasound during uterine artery embolization:: A pilot study
    Dorenberg, Eric J.
    Jakobsen, Jarl A.
    Brabrand, Knut
    Hafsahl, Geir
    Smith, Hans-Jorgen
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (05) : 882 - 887