Two stage ecological hybrid sorption-compression refrigeration cycle

被引:20
作者
Cyklis, Piotr [1 ]
机构
[1] Politech Krakowska M 5, PL-31864 Krakow, Poland
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 48卷
关键词
Two stage hybrid sorption-compression refrigeration; WATER ADSORPTION CHILLER; PERFORMANCE EVALUATION; CO2; REFRIGERATION; TRIGENERATION; OPTIMIZATION; INTEGRATION; SIMULATION; SYSTEMS; ENERGY;
D O I
10.1016/j.ijrefrig.2014.08.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low critical point of CO2 results in transcritical refrigeration cycles with low efficiency and high discharge pressure. H2O has a high triple point temperature that limits its application to temperatures above 0 degrees C. In this paper the two stage hybrid cycle is presented, where the Low Temperature (LT) stage is the compression cycle with CO2 and the High Temperature (HT) stage is the H2O sorption cycle. The choice between absorption and adsorption technology depends on the application and most of all is related to the temperature available for the desorber. This paper presents the adsorption technology on the HT stage powered by solar thermal energy. The combined hybrid cycle has been tested for two years at the Politechnika Krakowska, and a summary of the results is shown in this paper. The experimental results have been compared with two-refrigerants, two stage cycles and CO2 - only cycles. (C) 2014 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 34 条
[1]   Performance studies on mechanical plus adsorption hybrid compression refrigeration cycles with HFC 134a [J].
Banker, N. D. ;
Dutta, P. ;
Prasad, M. ;
Srinivasan, K. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (08) :1398-1406
[2]   Study on a compact silica gel-water adsorption chiller without vacuum valves: Design and experimental study [J].
Chen, C. J. ;
Wang, R. Z. ;
Xia, Z. Z. ;
Kiplagat, J. K. ;
Lu, Z. S. .
APPLIED ENERGY, 2010, 87 (08) :2673-2681
[3]  
Cyklis P., 2011, P 23 IIR INT C REFR, P8
[4]  
Cyklis P., 2008, T I FLUID FLOW MACH, V121, P49
[5]  
Cyklis P., 2011, POZN 1 INT C THERM, P422
[6]   Proposal and validation of a model for the dynamic simulation of a solar-assisted single-stage LiBr/water absorption chiller [J].
Evola, G. ;
Le Pierres, N. ;
Boudehenn, F. ;
Papillon, P. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03) :1015-1028
[7]   Design and construction of a LiBr-water absorption machine [J].
Florides, GA ;
Kalogirou, SA ;
Tassou, SA ;
Wrobel, LC .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (15) :2483-2508
[8]   Waste heat driven absorption/vapor-compression cascade refrigeration system for megawatt scale, high-flux, low-temperature cooling [J].
Garimella, Srinivas ;
Brown, Ashlie M. ;
Nagavarapu, Ananda Krishna .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (08) :1776-1785
[9]  
Grzebielec Andrzej, 2009, Archives of Thermodynamics, V30, P189
[10]   Performance evaluation of combined adsorption refrigeration cycles [J].
Habib, Khairul ;
Saha, Bidyut Baran ;
Chakraborty, Anutosh ;
Koyama, Shigeru ;
Srinivasan, Kandadai .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :129-137