Power Quality Enhancement Using a New Hybrid Active Power Filter Under Non-Ideal Source and Load Conditions

被引:0
|
作者
Hosseini, Seyed Hossein [1 ]
Nouri, Tohid [1 ]
Sabahi, Mehran [1 ]
机构
[1] Univ Tabriz, Fac Elect & Comp Engn, Tabriz 51666, Iran
关键词
Reactive power compensation; power quality; hybrid power filter; passive filter; COMPENSATION; SYSTEMS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Harmonic and reactive power compensation are important power quality problems. In this paper a new hybrid power filter is proposed which consists of a series tuned passive filter and small rated shunt active filter. Passive filter is tuned at fifth and seventh order harmonic frequencies. At this frequencies passive filter impedance is high which blocks them to appear in utility side. Consequently active filter compensates for third and higher order harmonics, unbalance current and reactive power under non-ideal source voltage condition. A new control method based on PHC strategy in d-q frame is presented for active part. The proposed system was simulated using Power System Blockset (PSB) Toolbox of Matlab. The simulation results show considerable decrease in active filter rating in the proposed hybrid structure and good performance of hybrid filter under load and source voltage perturbation simultaneously.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 50 条
  • [21] A Novel Control Method for Unified Power Quality Conditioner (UPQC) Under Non-Ideal Mains Voltage and Unbalanced Load Conditions
    Kesler, Metin
    Ozdemir, Engin
    2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 374 - 379
  • [22] Why we use the term non-active power, and how it can be measured under non-ideal power supply conditions
    Gaunt, C. T.
    Malengret, M.
    2012 IEEE POWER ENGINEERING SOCIETY CONFERENCE AND EXPOSITION IN AFRICA (POWERAFRICA), 2012,
  • [23] Improved Single Phase SRF Algorithm for CHB Inverter Based Shunt Active Power Filter under Non-ideal Supply Conditions
    Ray, Soumyadeep
    Gupta, Nitin
    Gupta, R. A.
    2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2017,
  • [24] RDFT based Control of a 3-phase 4-leg Shunt Active Power Filter under Unbalanced Load and Non-ideal Mains Voltage Conditions
    Hosseinpour, Majid
    Mohamadian, Mustafa
    Varjani, Ali Yazdian
    2014 22nd Iranian Conference on Electrical Engineering (ICEE), 2014, : 739 - 745
  • [25] Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages
    Chang, GW
    Yeh, CM
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 182 - 190
  • [26] Power Quality Improvement by using Shunt Hybrid Active Power Filter
    Tahmid, Rashik
    Ahmad, Shameem
    2017 INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION ENGINEERING (ECCE), 2017, : 381 - 386
  • [27] Investigating the ability of shunt hybrid power filter based on SRF method under non-ideal supply voltage
    Omran, Mohamed A.
    Mohd, Izzeldin I.
    Almelian, Mohamad M.
    Sheikh, Usman Ullah
    Bofares, Mustafa E. A. A.
    INTERNATIONAL CONFERENCE ON INNOVATIVE TECHNOLOGY, ENGINEERING AND SCIENCES 2018 (ICITES 2018), 2018, 342
  • [28] A new serial hybrid active power filter using controllable current source
    Chen, GZ
    Lu, ZY
    Qian, ZM
    Peng, FZ
    PESC'02: 2002 IEEE 33RD ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2002, : 364 - 368
  • [29] Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement
    Mishra, Alok K.
    Ray, Prakash K.
    Mallick, Ranjan K.
    Mohanty, Asit
    Das, Soumya R.
    NEURAL COMPUTING & APPLICATIONS, 2021, 33 (05): : 1435 - 1452
  • [30] Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement
    Alok K. Mishra
    Prakash K. Ray
    Ranjan K. Mallick
    Asit Mohanty
    Soumya R. Das
    Neural Computing and Applications, 2021, 33 : 1435 - 1452