The Effect of Test Distance on Visual Contrast Sensitivity Measured Using the Pelli-Robson Chart

被引:11
|
作者
Njeru, Stevie M. [1 ]
Osman, Mawada [1 ]
Brown, Angela M. [1 ]
机构
[1] Ohio State Univ, Coll Optometry, 338 West 10th Ave, Columbus, OH 43210 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2021年 / 10卷 / 02期
基金
美国国家卫生研究院;
关键词
Pelli-Robson (PR); Ohio Contrast Cards (OCCs); contrast sensitivity (CS); low vision; elderly; VALIDATION; DESIGN;
D O I
10.1167/tvst.10.2.32
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Conclusions: PR CS should be measured at a distance in meters that is equal to the patient?s letter acuity in cy/deg, or 1.5?logMAR. Translational Relevance: Contrast sensitivity is highly associated with quality of life, and it is important to measure it accurately. Using a closer distance, or measuring grating CS, can reveal visual abilities missed when patients with low vision are tested using PR at 1 meter. <comment>Superscript/Subscript Available</comment> ABSTRACT Purpose: The Pelli-Robson (PR) chart is widely used to measure clinical contrast sensitivity (CS). It is generally believed that PR testing distance is not critical. Here, we examine whether a closer test distance than the usual 1 meter might be better for patients with low vision. Methods: PR CS was measured on two groups: low-vision students (< 20 years old) and elder patients (> 65 years old). Student PR was measured at 1 meter and at a closer distance d = visual acuity in log10cy/deg (d = 1.5-logMAR). Elder PR was measured at 1 and 3 meters. Grating CS was also measured using the Ohio Contrast Cards (OCCs). Results: Average CS was 0.398 log10 units (over one line on the PR chart) higher at the closer distance than at 1 meter for the students, but there was no effect of 1 vs. 3 meters test distance for the elders. The equivalent spatial frequencies of the PR letters at 1 meter were near the acuity limits of students with low vision, but were near the peak of the elders' CS functions. Especially for students with low vision, PR CS was below OCC CS, even when PR was tested at a closer distance. Conclusions: PR CS should be measured at a distance in meters that is equal to the patient's letter acuity in cy/deg, or 1.5-logMAR. Translational Relevance: Contrast sensitivity is highly associated with quality of life, and it is important to measure it accurately. Using a closer distance, or measuring grating CS, can reveal visual abilities missed when patients with low vision are tested using PR at 1 meter.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 12 条
  • [1] IMPROVING THE RELIABILITY OF THE PELLI-ROBSON CONTRAST SENSITIVITY TEST
    ELLIOTT, DB
    BULLIMORE, MA
    BAILEY, IL
    CLINICAL VISION SCIENCES, 1991, 6 (06): : 471 - 475
  • [2] Assessment of contrast sensitivity by Spaeth Richman Contrast Sensitivity Test and Peli Robson Chart Test in patients with varying severity of glaucoma
    Thakur, Sahil
    Ichhpujani, Parul
    Kumar, Suresh
    Kaur, Ravneet
    Sood, Sunandan
    EYE, 2018, 32 (08) : 1392 - 1400
  • [3] Relationship of Contrast Sensitivity Measured Using Quick Contrast Sensitivity Function With Other Visual Functions in a Low Vision Population
    Stalin, Amritha
    Dalton, Kristine
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (06)
  • [4] Normative contrast sensitivity values for the back-lit Melbourne Edge Test and the effect of visual impairment
    Eperjesi, F
    Wolffsohn, J
    Bowden, J
    Napper, G
    Rubinstein, M
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (06) : 600 - 606
  • [5] A chart-based test of contrast sensitivity in noise: reference ranges, effects of age and optical abnormality
    McAnany, J. Jason
    Collison, Frederick T.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024,
  • [6] EVALUATING CONTRAST SENSITIVITY IN AGE-RELATED MACULAR DEGENERATION USING A NOVEL COMPUTER-BASED TEST, THE SPAETH/RICHMAN CONTRAST SENSITIVITY TEST
    Faria, Bruno M.
    Duman, Fulya
    Zheng, Cindy X.
    Waisbourd, Michael
    Gupta, Lalita
    Ali, Mohsin
    Zangalli, Camila
    Lu, Lan
    Wizov, Sheryl S.
    Spaeth, Eric
    Richman, Jesse
    Spaeth, George L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (07): : 1465 - 1473
  • [7] The effect of oral isotretinoin on visual contrast sensitivity and amount of lacrimation in patients with acne vulgaris
    Polat, Mualla
    Kukner, Sahap
    CUTANEOUS AND OCULAR TOXICOLOGY, 2017, 36 (01) : 35 - 38
  • [8] Contrast sensitivity in children with severe visual impairment and its effect on their functional ability.
    Siddiqui, AP
    Rydberg, A
    Zaman, S
    TRANSACTIONS: 27TH MEETING OF THE EUROPEAN STRABISMOLOGICAL ASSOCIATION, 2001, : 63 - 66
  • [9] The effect of filters and varying illumination on contrast sensitivity in eyes with moderate to severe visual impairment
    Carl Halladay Abraham
    Enyam Morny
    Asantewaa Aboagye-MacCarthy
    Stephen Ocansey
    Michael Ntodie
    Godfred Sakyi-Badu
    Albert Kofi Dadzie
    Naa Adjeley Addo
    Selina Holdbrook
    Emmanuel Kwasi Abu
    International Ophthalmology, 2023, 43 : 3329 - 3337
  • [10] The effect of filters and varying illumination on contrast sensitivity in eyes with moderate to severe visual impairment
    Abraham, Carl Halladay
    Morny, Enyam
    Aboagye-MacCarthy, Asantewaa
    Ocansey, Stephen
    Ntodie, Michael
    Sakyi-Badu, Godfred
    Dadzie, Albert Kofi
    Addo, Naa Adjeley
    Holdbrook, Selina
    Abu, Emmanuel Kwasi
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (09) : 3329 - 3337