Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis

被引:94
作者
Falco, Antonello [1 ]
Berardini, Marco [1 ]
Trisi, Paolo [1 ]
机构
[1] Biomat Clin & Histol Res Assoc, Pescara, Italy
关键词
bone density; implant geometry; insertion torque; osseointegration; primary implant stability; MARGINAL BONE-RESORPTION; TITANIUM IMPLANTS; DENTAL IMPLANTS; SURGICAL TECHNIQUE; DENSITY; DESIGN; MICROMOTION; PROTOCOLS; QUALITY; SHAPE;
D O I
10.11607/jomi.6285
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Primary implant stability represents the first step for successful osseointegration. The knowledge of the correlation between host bone density, insertion torque, and implant macrogeometry seems to be fundamental to achieve sufficient primary implant bone fixation in each clinical situation. The purpose of this study was to measure, in vitro, the impact of dental implant macrogeometry and insertion torque values on primary stability in relation to different bone densities, representing both the human mandible and maxilla. Materials and Methods: One hundred twenty 3.8 x 11-mm commercial dental implants were used. Forty implants had small threads with a machined neck, 40 implants had small threads with a microthreaded neck, and the last 40 implants had large threads with a reverse neck design. Fresh bovine ribs, representing a medium-dense bone density (D2-D3), and fresh ovine iliac crest, representing a soft bone density (D4), were used. Insertion torque and micromobility under lateral force data were recorded for each implant. Results: In the medium-dense bone type, the reverse neck implant design showed less primary implant stability than the conventional straight implant neck. In soft bone, both implants with the large thread design and microthreaded neck implants showed better implant stability than the implant with a small thread design with a straight machined neck. Implants with large and self-cutting threads showed significantly (P < .05) lower micromobility values than other implants in postextractive sites in low-density bone. Conclusion: Implant geometries and bone density are the main factors involved in the degree of primary implant stability. Large-thread implant designs are highly desirable in cases of poor bone quality. Each implant geometry generates an insertion torque value, which is correlated to the stability of that specific implant in a specific bone quality, but the insertion torque is not an objective value to compare primary stability between different implant types.
引用
收藏
页码:824 / 830
页数:7
相关论文
共 33 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]   The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses [J].
Berardini, Marco ;
Trisi, Paolo ;
Sinjari, Bruna ;
Rutjes, Anne W. S. ;
Caputi, Sergio .
IMPLANT DENTISTRY, 2016, 25 (04) :532-540
[3]   Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study [J].
Bilhan, Hakan ;
Bilmenoglu, Caglar ;
Urgun, Aliye Ceren ;
Ates, Gokcen ;
Bural, Canan ;
Cilingir, Altug ;
Geckili, Onur .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) :1036-1040
[4]  
Cannizzaro G, 2012, EUR J ORAL IMPLANTOL, V5, P333
[5]   EFFECT OF IMPLANT DESIGN ON INITIAL STABILITY OF TAPERED IMPLANTS [J].
Chong, Linus ;
Khocht, Ahmed ;
Suzuki, Jon B. ;
Gaughan, John .
JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (03) :130-135
[6]   Effects of implant neck design on primary stability and overload in a type IV mandibular bone [J].
Chou, I-Chiang ;
Lee, Shyh-Yuan ;
Jiang, Cho-Pei .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (11) :1223-1237
[7]   Analyzing the Influence of a New Dental Implant Design on Primary Stability [J].
da Costa Valente, Mariana Lima ;
de Castro, Denise Tornavoi ;
Shimano, Antonio Carlos ;
Lepri, Cesar Penazzo ;
dos Reis, Andrea Candido .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) :168-173
[8]   Analysis of the influence of implant shape on primary stability using the correlation of multiple methods [J].
da Costa Valente, Mariana Lima ;
de Castro, Denise Tornavoi ;
Shimano, Antonio Carlos ;
Lepri, Cesar Penazzo ;
dos Reis, Andrea Candido .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) :1861-1866
[9]   Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study [J].
Degidi, Marco ;
Daprile, Giuseppe ;
Piattelli, Adriano .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :37-41
[10]   The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants [J].
dos Santos, Mychelle Vianna ;
Elias, Carlos Nelson ;
Cavalcanti Lima, Jose Henrique .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :215-223