A versatile high-speed bipolar charge-sensitive preamplifier for calorimeter applications

被引:1
|
作者
Baschirotto, A
Castello, R
Pessina, G
Rancoita, PG
Seidman, A
机构
[1] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[2] Univ Pavia, Dipartimento Elettron, I-27100 Pavia, Italy
[3] Tel Aviv Univ, Dept Phys Elect, IL-69978 Tel Aviv, Israel
关键词
D O I
10.1109/4.663570
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-speed charge-sensitive preamplifier (CSP) to be used in silicon calorimeters has been realized, The main features of this circuit are: high slew rate (larger than 500 V/mu s), low noise, large output swing (5 V), high dynamic range (of the order of 90 dB), and 50-Ohm output drive capability, In addition, the CSP is designed to allow adaptation of its power-versus-noise performance to different experimental conditions, The bias current of the input device can be adjusted with an external component, in order to optimize the tradeoff between power consumption and noise, The power supply can be set in the 3.3-12-V range, optimizing the power dissipation over output swing ratio. The CSP was realized in a bipolar technology whose bipolar transistors have been previously tested before and after being subjected to irradiation, The results were taken into account in the design in order to achieve CSP radiation-hard performance.
引用
收藏
页码:635 / 639
页数:5
相关论文
共 50 条
  • [1] ON A NEW FAST CHARGE-SENSITIVE PREAMPLIFIER
    QUARANTA, AA
    MARTINI, M
    OTTAVIANI, G
    ZANARINI, G
    NUCLEAR INSTRUMENTS & METHODS, 1965, 32 (02): : 352 - +
  • [2] DEVELOPMENT AND EVALUATION OF CHARGE-SENSITIVE PREAMPLIFIER FOR CSI CALORIMETER IN THE KEK B-FACTORY
    TANAKA, M
    IKEDA, H
    TAMAI, K
    TAKEMOTO, M
    HAYASHII, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1208 - 1211
  • [3] The simulation with orCAD for charge-sensitive preamplifier designed
    Liu, Liang-Jun
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (03): : 425 - 427
  • [4] AN OVERLOAD CANCELLATION CIRCUIT FOR A CHARGE-SENSITIVE PREAMPLIFIER
    SATTERFIELD, MM
    DYER, GR
    MCCLAIN, WJ
    NUCLEAR INSTRUMENTS & METHODS, 1969, 75 (02): : 312 - +
  • [5] Miniature charge-sensitive preamplifier for compound semiconductor detector
    Liu, Zhengshan
    Zhang, Zhiyong
    Deng, Changming
    Cheng, Chang
    Su, Xiaohui
    Li, Mei
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 17 (06): : 465 - 468
  • [6] A MONOLITHIC RADIATION-TOLERANT CHARGE-SENSITIVE PREAMPLIFIER
    BUTTLER, W
    CITTERIO, M
    LUTZ, G
    MANFREDI, PF
    RE, V
    SPEZIALI, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (02): : 435 - 438
  • [7] The application of Multisim software to the analyzing of the charge-sensitive preamplifier
    Zhou, Chao
    Yang, Bin-Hua
    Zhao, Xiu-Liang
    Yin, Chen-Yan
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (03): : 502 - 506
  • [8] DETECTION UNIT WITH CORRELATION CHARGE-SENSITIVE PREAMPLIFIER.
    Pod'yachev, V.N.
    Instruments and experimental techniques New York, 1980, 23 (4 pt 2): : 944 - 947
  • [9] NUCLEAR ELECTRONICS - CHARGE-SENSITIVE PREAMPLIFIER FOR SEMICONDUCTOR DETECTORS
    STANEK, FW
    KERNTECHNIK, 1969, 11 (05) : 286 - &
  • [10] A Versatile Low-Noise Wide-Range Charge-Sensitive Preamplifier for HPGe Detectors
    Pullia, A.
    Pascovici, G.
    Ur, C.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 815 - 818