Effect of stent size on complications and recurrent dysphagia in patients with esophageal or gastric cardia cancer

被引:103
作者
Verschuur, Els M. L.
Steyerberg, Ewout W.
Kuipers, Ernst J.
Siersema, Peter D.
机构
[1] Erasmus MC Univ, Med Ctr Rotterdam, Dept Gastroenterol & Hepatol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC Univ, Med Ctr Rotterdam, Dept Publ Hlth, NL-3000 CA Rotterdam, Netherlands
关键词
D O I
10.1016/j.gie.2006.12.018
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Stents are commonly used for the palliation of dysphagia from esophageal or gastric cardia cancer. A major drawback of stents is the occurrence of recurrent dysphagia. Large-diameter stents were introduced for the prevention of migration but may be associated with more complications. Objective: To compare small- and large-diameter stents for improvement of dysphagia, complications, and recurrent dysphagia. Design: Evaluation of 338 prospectively followed patients with dysphagia from obstructing esophageal or gastric cardia cancer who were treated with an Ultraflex stent (n = 153), a Gianturco Z-stent (n = 89), or a Flamingo Wallstent (n = 96) of either a small diameter (n = 265) or a large diameter (n = 73) during the period 1996 to 2004. Setting: Single academic center. Patients: Patients with an inoperable malignant obstruction of the esophagus or the gastric cardia, or recurrent dysphagia after prior radiation, with curative or palliative intent for esophageal cancer. Interventions: Stent placement. Main Outcome Measurements: Dysphagia score (on a scale from 0 [no dysphagia] to 4 [complete dysphagia]), complications, and recurrent dysphagia. Analysis was by chi(2) test, log-rank test, and Cox regression analysis. Results: Improvement in dysphagia was similar between patients with a small- or a large-diameter stent (P = .35). The occurrence of major complications, such as hemorrhage, perforation, fistula, and fever, was increased in patients with a large-diameter Gianturco Z-stent compared with those treated with a small-diameter stent (4 [40%] vs 16 [20%]; adjusted hazard ratio [HR] 5.03, 95% confidence interval [CI] 1.33-19.11) but not in patients with a large-diameter Ultraflex stent or a Flamingo Wallstent. Moreover, minor complications, particularly pain, were associated with prior radiation and/or chemotherapy in patients with a large- or a small-diameter Gianturco Z-stent (HR 4.27, 95% CI 1.44-12.71) but not in those with an Ultraflex stent or a Flamingo Wallstent. Dysphagia from stent migration, tissue overgrowth, and food bolus obstruction reoccurred more frequently in patients with a small-diameter stent than in those with a large-diameter stent (Ultraflex stent: 54 [42%] vs 3 [13%], adjusted HR 0.16, 95% Cl 0.04-0.74; Gianturco Z-stent: 21 [27%] vs 1 [10%], adjusted HR 0.97, 95% CI 0.11-8.67; and Flamingo Wallstent: 21 [37%] vs 6 [15%], adjusted HR 0.40, 95% CI 0.03-4.79). Limitations: Nonrandomized study design. Conclusions: Large-diameter stents reduce the risk of recurrent dysphagia from stent migration, tissue overgrowth, or food obstruction. Increasing the diameter in some stent types may, however, increase the risk of stent-related complications to the esophagus.
引用
收藏
页码:592 / 601
页数:10
相关论文
共 10 条
[1]   Current concepts: Expandable metal stents for the treatment of cancerous obstruction of the gastrointestinal tract. [J].
Baron, TH .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (22) :1681-1687
[2]  
Cwikiel W, 1997, ACTA RADIOL, V38, P124
[3]   Oesophagorespiratory fistulas as a complication of self-expanding metal oesophageal stents [J].
Hasan, S ;
Beckly, D ;
Rahamim, J .
ENDOSCOPY, 2004, 36 (08) :731-734
[4]   Single-dose brachytherapy versus metal stent placement for the palliation of dysphagia from oesophageal cancer: multicentre randomised trial [J].
Homs, MYV ;
Steyerberg, EW ;
Eijkenboom, WMH ;
Tilanus, HW ;
Stalpers, LJA ;
Bartelsman, JFWM ;
van Lanschot, JJB ;
Wijrdeman, HK ;
Mulder, CJJ ;
Reinders, JG ;
Boot, H ;
Aleman, BMP ;
Kuipers, E ;
Siersema, PD .
LANCET, 2004, 364 (9444) :1497-1504
[5]   Nonmalignant obstruction is a common problem with metal stents in the treatment of esophageal cancer [J].
Mayoral, W ;
Fleischer, D ;
Salcedo, J ;
Roy, P ;
Al-Kawas, F ;
Benjamin, S .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (05) :556-559
[6]   large-diameter metal stents are associated with stent-related esophageal complications [J].
Siersema, PD ;
Homs, MYV ;
Kuipers, EJ .
ENDOSCOPY, 2005, 37 (06) :600-600
[7]   A new design metal stent (Flamingo stent) for palliation of malignant dysphagia: a prospective study [J].
Siersema, PD ;
Hop, WCJ ;
van Blankenstein, M ;
Dees, J .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (02) :139-145
[8]   Metal Stents for tumors of the distal esophagus and gastric cardia [J].
Siersema, PD ;
Marcon, N ;
Vakil, N .
ENDOSCOPY, 2003, 35 (01) :79-85
[9]   A comparison of 3 types of covered metal stents for the palliation of patients with dysphagia caused by esophagogastric carcinoma: a prospective, randomized study [J].
Siersema, PD ;
Hop, WCJ ;
van Blankenstein, M ;
van Tilburg, AJP ;
Bac, DJ ;
Homs, MYV ;
Kuipers, EJ .
GASTROINTESTINAL ENDOSCOPY, 2001, 54 (02) :145-153
[10]   Improved prognosis of resected esophageal cancer [J].
Stein, HJ ;
Siewert, JR .
WORLD JOURNAL OF SURGERY, 2004, 28 (06) :520-525