Small-invasive determination of iron content in coating of galvanized steel sheets by laser-induced breakdown spectroscopy

被引:6
作者
Sun, Lan-xiang [1 ,2 ]
Wang, Wei-ye [1 ,2 ,3 ]
Guo, Mei-ting [1 ,2 ]
Tian, Xue-yong [4 ]
Zhang, Peng [1 ,2 ,5 ]
Qi, Li-feng [1 ,2 ]
Yu, Hai-bin [1 ,2 ]
Zeng, Peng [1 ,2 ]
机构
[1] Chinese Acad Sci, Shenyang Inst Automat, Shenyang 110016, Liaoning, Peoples R China
[2] Chinese Acad Sci, Key Lab Networked Control Syst, Shenyang 110016, Liaoning, Peoples R China
[3] Northeastern Univ, Shenyang 110819, Liaoning, Peoples R China
[4] SIASUN Robot & Automat Co Ltd, Cent Res Inst, Shenyang 110168, Liaoning, Peoples R China
[5] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced breakdown spectroscopy; Galvanized steel sheet; Quantitative analysis; Small-invasive analysis; Iron content; DEPTH-PROFILE ANALYSIS; QUANTITATIVE ELEMENTAL ANALYSIS; INDUCED PLASMA; ZINC; LIBS; FE; BEHAVIOR; SAMPLES; ELECTRODEPOSITION; SPECTROMETRY;
D O I
10.1007/s42243-019-00320-z
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A new method was presented to determine the iron content in the coating of galvanized steel sheet based on laser-induced breakdown spectroscopy. The zinc-iron coating was characterized with a series of single laser pulses irradiated on the traversing sheet steel, each on a different steel sheet position. The influences of laser fluence and elemental depth distribution were studied and analyzed. To protect the corrosion performance of the coating and meet requirements for small-invasive measurement, the ablation size of the crater under different laser fluences was studied. Under the optimized experimental parameters, the diameter of ablation craters is about 50 mu m, and then, the Fe content in the coating was calibrated and analyzed by the linear standard calibration method. The calibration result, however, is not good. Considering that the Zn content in the coating was high and relatively constant, curve calibration was then carried out with the intensity ratio (I-Fe404: 58=I-Zn468:01) instead of the net line intensity of Fe, and then, the determination coefficient of calibration curve increases from 0.7713 to 0.9511, and the root-mean-square error decreases from 0.4832% to 0.1509%. The results prove that the laser-induced breakdown spectroscopy is an effective way for the analysis of the Fe content in the coating of galvanized steel sheet.
引用
收藏
页码:1137 / 1146
页数:10
相关论文
共 41 条
  • [1] Underwater measurements using laser induced breakdown spectroscopy
    Angel, S. Michael
    Bonvallet, Joseph
    Lawrence-Snyder, Marion
    Pearman, William F.
    Register, Janna
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) : 328 - 336
  • [2] Rapid, automated measurement of layer thicknesses on steel coin blanks using laser-induced-breakdown spectroscopy depth profiling
    Asimellis, George
    Giannoudakos, Aggelos
    Kompitsas, Michael
    [J]. APPLIED OPTICS, 2007, 46 (06) : 935 - 942
  • [3] New approach to online monitoring of the Al depth profile of the hot-dip galvanised sheet steel using LIBS
    Balzer, H
    Hoehne, M
    Noll, R
    Sturm, V
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (02) : 225 - 233
  • [4] Online coating thickness measurement and depth profiling of zinc coated sheet steel by laser-induced breakdown spectroscopy
    Balzer, H
    Hoehne, M
    Sturm, V
    Noll, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (7-8) : 1172 - 1178
  • [5] Analysis of the Fe-Zn interface of galvanized high Al-low Si TRIP steels
    Bellhouse, E. M.
    McDermid, J. R.
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 491 (1-2): : 39 - 46
  • [6] Early stage expansion and time-resolved spectral emission of laser-induced plasma from polymer
    Boueri, Myriam
    Baudelet, Matthieu
    Yu, Jin
    Mao, Xianglei
    Mao, Samuel S.
    Russo, Richard
    [J]. APPLIED SURFACE SCIENCE, 2009, 255 (24) : 9566 - 9571
  • [7] Optimization of parameters for depth resolution of galvanized steel by LIBS technique
    Canel, T.
    Demir, P.
    Kacar, E.
    Oztoprak, B. Genc
    Akman, E.
    Gunes, M.
    Demir, A.
    [J]. OPTICS AND LASER TECHNOLOGY, 2013, 54 : 257 - 264
  • [8] Correction of matrix effects in quantitative elemental analysis with laser ablation optical emission spectrometry
    Chaleard, C
    Mauchien, P
    Andre, N
    Uebbing, J
    Lacour, JL
    Geertsen, C
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 183 - 188
  • [9] Laser ablation of powdered samples and analysis by means of laser-induced breakdown spectroscopy
    Ctvrtnickova, T.
    Cabalin, L.
    Laserna, J.
    Kanicky, V.
    Nicolas, G.
    [J]. APPLIED SURFACE SCIENCE, 2009, 255 (10) : 5329 - 5333
  • [10] Good practices in LIBS analysis: Review and advices
    El Haddad, J.
    Canioni, L.
    Bousquet, B.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 171 - 182