Extension of the reconstruction field of view and truncation correction using sinogram decomposition

被引:42
作者
Zamyatin, Alexander A.
Nakanishi, Satoru
机构
[1] Toshiba Med Res Inst USA, Vernon Hills, IL 60061 USA
[2] Toshiba Med Syst Corp, Ct Syst Div, Applicat & Res Grp, Otawara, Tochigi 3248550, Japan
关键词
fan beam CT; truncation correction; field-of-view extension; sinogram decomposition;
D O I
10.1118/1.2721656
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We propose a novel truncation correction algorithm that completes unmeasured data outside of the scan field of view, which allows extending the reconstruction field of view. When a patient extends outside the detector coverage the projection data are transversely truncated, which causes severe artifacts. The proposed method utilizes the idea of sinogram decomposition, where we consider sinogram curves corresponding to image points outside the field of view. We propose two ways to estimate the truncated data, one based on the minimum value along the sinogram curve, and the other based on the data values near the edge of truncation. Both estimation methods are combined to achieve uniform image quality improvement from the edge of truncation to the outer side of the extended region. In our evaluation with simulated and real projection data we compare the proposed method with existing methods and investigate the dependence on the amount of truncation. The evaluation shows that the proposed method handles cases when truncation is present on both sides of the detector, or when a high-contrast object is located outside the field of view. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1593 / 1604
页数:12
相关论文
共 22 条
[1]  
CARAMELO FJ, 2005, 8 INTL M FULL 3D IM, P55
[2]   Artifact reduction in truncated CT using Sinogram completion [J].
Chityala, R ;
Hoffmann, KR ;
Rudin, S ;
Bednarek, DR .
Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 :2110-2117
[3]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[4]   Quantitative reconstruction from truncated projections in classical tomography [J].
Clackdoyle, R ;
Noo, F ;
Guo, JY ;
Roberts, JA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2570-2578
[5]   RECONSTRUCTION OF OBJECTS FROM INCOMPLETE PROJECTIONS [J].
GORE, JC ;
LEEMAN, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) :129-136
[6]   Technical note: Sinogram merging to compensate for truncation of projection data in tomotherapy imaging [J].
Hooper, HR ;
Fallone, BG .
MEDICAL PHYSICS, 2002, 29 (11) :2548-2551
[7]   A novel reconstruction algorithm to extend the CT scan field-of-view [J].
Hsieh, J ;
Chao, E ;
Thibault, J ;
Grekowicz, B ;
Horst, A ;
McOlash, S ;
Myers, TJ .
MEDICAL PHYSICS, 2004, 31 (09) :2385-2391
[8]  
KRESTYANNIKOV E, 2004, 2004 IEEE NUCL SCI S
[9]   Exact fain-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector [J].
Leng, S ;
Zhuang, TL ;
Nett, BE ;
Chen, GH .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1805-1820
[10]   A two-step Hilbert transform method for 2D image reconstruction [J].
Noo, F ;
Clackdoyle, R ;
Pack, JD .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) :3903-3923