Using a saline chaser to decrease contrast media in abdominal CT

被引:60
作者
Dorio, PJ [1 ]
Lee, FT [1 ]
Henseler, KP [1 ]
Pilot, M [1 ]
Pozniak, MA [1 ]
Winter, TC [1 ]
Shock, SA [1 ]
机构
[1] Univ Wisconsin Hosp & Clin, Dept Radiol, Madison, WI 53792 USA
关键词
D O I
10.2214/ajr.180.4.1800929
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus A 50-mL saline chaser. SUBJECTS AND METHODS. We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava. RESULTS. The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser. CONCLUSION. Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.
引用
收藏
页码:929 / 934
页数:6
相关论文
共 17 条
  • [1] Pancreatic-phase versus portal vein-phase helical CT of the pancreas: Optimal temporal window for evaluation of pancreatic adenocarcinoma
    Boland, GW
    O'Malley, ME
    Saez, M
    Fernandez-del-Castillo, C
    Warshaw, AL
    Mueller, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) : 605 - 608
  • [2] HYPERVASCULAR HEPATIC METASTASES - CT EVALUATION
    BRESSLER, EL
    ALPERN, MB
    GLAZER, GM
    FRANCIS, IR
    ENSMINGER, WD
    [J]. RADIOLOGY, 1987, 162 (01) : 49 - 51
  • [3] Dawson-Saunders B, 1994, BASIC CLIN BIOSTATIS, P41
  • [4] Edmondson HA, 1982, DISEASES LIVER, P1101
  • [5] Selective use of radiographic low-osmolality contrast media in the 1990s
    Ellis, JH
    Cohan, RH
    Sonnad, SS
    Cohan, NS
    [J]. RADIOLOGY, 1996, 200 (02) : 297 - 311
  • [6] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [7] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [8] HEPATIC HELICAL CT - EFFECT OF REDUCTION OF IODINE DOSE OF INTRAVENOUS CONTRAST MATERIAL ON HEPATIC CONTRAST ENHANCEMENT
    FREENY, PC
    GARDNER, JC
    VONINGERSLEBEN, G
    HEYANO, S
    NGHIEM, HV
    WINTER, TC
    [J]. RADIOLOGY, 1995, 197 (01) : 89 - 93
  • [9] Hänninen EL, 2000, RADIOLOGY, V216, P403
  • [10] Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    Hopper, KD
    Mosher, TJ
    Kasales, CJ
    TenHave, TR
    Tully, DA
    Weaver, JS
    [J]. RADIOLOGY, 1997, 205 (01) : 269 - 271