In Vivo Real-Time 3-D Intracardiac Echo Using PMUT Arrays

被引:96
作者
Dausch, David E. [1 ]
Gilchrist, Kristin H. [1 ]
Carlson, James B. [1 ]
Hall, Stephen D. [1 ]
Castellucci, John B. [2 ]
von Ramm, Olaf T. [2 ]
机构
[1] RTI Int, Elect & Appl Phys Div, Res Triangle Pk, NC 27709 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
关键词
3-DIMENSIONAL ECHOCARDIOGRAPHY; 2-D ARRAY; CATHETER; ABLATION; GUIDANCE; CLOSURE; UTILITY;
D O I
10.1109/TUFFC.2014.006452
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Piezoelectric micromachined ultrasound transducer (PMUT) matrix arrays were fabricated containing novel through-silicon interconnects and integrated into intracardiac catheters for in vivo real-time 3-D imaging. PMUT arrays with rectangular apertures containing 256 and 512 active elements were fabricated and operated at 5 MHz. The arrays were bulk micromachined in silicon-on-insulator substrates, and contained flexural unimorph membranes comprising the device silicon, lead zirconate titanate (PZT), and electrode layers. Through-silicon interconnects were fabricated by depositing a thin-film conformal copper layer in the bulk micromachined via under each PMUT membrane and photolithographically patterning this copper layer on the back of the substrate to facilitate contact with the individually addressable matrix array elements. Cable assemblies containing insulated 45-AWG copper wires and a termination silicon substrate were thermocompression bonded to the PMUT substrate for signal wire interconnection to the PMUT array. Side-viewing 14-Fr catheters were fabricated and introduced through the femoral vein in an adult porcine model. Real-time 3-D images were acquired from the right atrium using a prototype ultrasound scanner. Full 60 degrees x 60 degrees volume sectors were obtained with penetration depth of 8 to 10 cm at frame rates of 26 to 31 volumes per second.
引用
收藏
页码:1754 / 1764
页数:11
相关论文
共 28 条
[1]  
Akai D., 2011, TRANSDUCERS 2011 - 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, P910, DOI 10.1109/TRANSDUCERS.2011.5969159
[2]  
Al Ahmad A, 2011, J CARDIOVASC ELECTR, V22, pS43
[3]   Intracardiac Echocardiography: Clinical Utility and Application [J].
Ali, Sheharyar ;
George, Lekha K. ;
Das, Pranab ;
Koshy, Santhosh K. G. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (05) :582-590
[4]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[5]   Intracardiac echocardiography in complex cardiac catheter ablation procedures [J].
Banchs, Javier E. ;
Patel, Parag ;
Naccarelli, Gerald V. ;
Gonzalez, Mario D. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 28 (03) :167-184
[6]   Real-time three-dimensional transoesophageal echocardiography during percutaneous transcatheter occlusion of mitral periprosthetic paravalvular leak [J].
Bogunovic, Nikola ;
Faber, Lothar ;
Scholtz, Werner ;
Mellwig, Klaus Peter ;
Horstkotte, Dieter ;
van Buuren, Frank .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (03) :E27
[7]  
Dausch David E., 2010, 2010 International Ultrasonics Symposium, P451, DOI 10.1109/ULTSYM.2010.0110
[8]  
Dausch D. E., 2010, P INT INT TECHN C, P1
[9]   Theory and Operation of 2-D Array Piezoelectric Micromachined Ultrasound Transducers [J].
Dausch, David E. ;
Castellucci, John B. ;
Chou, Derrick R. ;
von Ramm, Olaf T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (11) :2484-2492
[10]   Value of Real-Time Transesophageal 3-Dimensional Echocardiography in Guiding Ablation of Isthmus-Dependent Atrial Flutter and Pulmonary Vein Isolation [J].
Faletra, Francesco F. ;
Regoli, Francois ;
Acena, Marta ;
Auricchio, Angelo .
CIRCULATION JOURNAL, 2012, 76 (01) :5-14