An application of pattern recognition for the comparison of trunk muscles EMG waveforms between subjects with and without chronic low back pain during flexion-extension and lateral bending tasks

被引:17
作者
Larivière, C
Gagnon, D [1 ]
Loisel, P
机构
[1] Univ Sherbrooke, Fac Educ Phys & Sport, Sherbrooke, PQ, Canada
[2] Univ Sherbrooke, Fac Med, Dept Chirurg Orthopedie, Sherbrooke, PQ, Canada
关键词
electromyography; low back pain; flexion-extension; lateral bending; trunk muscles; lumbar impairment; principal component analysis; pattern recognition;
D O I
10.1016/S1050-6411(00)00013-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of the study was twofold: (1) to evaluate the reliability of distance measures computed from a principal component analysis (PCA) of electromyographic (EMG) waveforms of trunk muscles recorded during standardized trunk movements and (2) to evaluate their sensitivity to the load lifted, the trunk range of motion (ROM) and to low back status. Thirty-three male subjects (18 normals, 15 suffering from non specific CLBP) aged between 35-45 years participated. The EMG signals from 12 trunk muscles and the kinematics of trunk segments were recorded during 12 tasks, The subjects performed flexion-extension and lateral bending (left and right) tasks (three complete cycles) with and without a 12 kg load and at different trunk ROM (maximal or at defined submaximal angles). Distance measures locating each subject relative to a reference PCA model were computed for each muscle and task. The reliability of these distance measures was evaluated for 10 subjects (five normals and five CLBP) who performed two tasks on three different days. The reliability of distance measures was acceptable for agonist muscles only. The distance measures were sensitive to the load lifted and to the trunk ROM for different muscles and tasks but poorly sensitive to low back status. Several reasons that could explain the low sensitivity of these measures to low back status are discussed and potential solutions are proposed. A procedure based on a reliability analysis is proposed to select the number of principal components to include in the reference PCA model. It is expected that the refinement of the method used in this study could provide an effective clinical tool to assess EMG waveforms of trunk muscles during dynamic tasks. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:261 / 273
页数:13
相关论文
共 52 条
[1]   EMG SIGNAL AMPLITUDE NORMALIZATION TECHNIQUE IN STRETCH-SHORTENING CYCLE MOVEMENTS [J].
ALLISON, GT ;
MARSHALL, RN ;
SINGER, KP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1993, 3 (04) :236-244
[2]  
[Anonymous], EUR J PHYS REHABIL M
[3]  
[Anonymous], 1983, HDB SURVEY RES
[4]  
[Anonymous], 1987, Spine, DOI DOI 10.1097/00007632-198701000-00001
[5]   ELECTROMYOGRAPHIC RECORDINGS OF 5 TYPES OF LOW-BACK PAIN SUBJECTS AND NON-PAIN CONTROLS IN DIFFERENT POSITIONS [J].
ARENA, JG ;
SHERMAN, RA ;
BRUNO, GM ;
YOUNG, TR .
PAIN, 1989, 37 (01) :57-65
[6]   An application of neural networks for distinguishing gait patterns on the basis of hip-knee joint angle diagrams [J].
Barton, JG ;
Lees, A .
GAIT & POSTURE, 1997, 5 (01) :28-33
[7]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[8]   TEMPORAL FEATURE-EXTRACTION AND CLUSTERING ANALYSIS OF ELECTROMYOGRAPHIC LINEAR ENVELOPES IN GAIT STUDIES [J].
CHEN, JJJ ;
SHIAVI, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :295-302
[9]   EMG NORMALIZATION [J].
DANOFF, JV .
PHYSICAL THERAPY, 1986, 66 (02) :270-270
[10]   The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163