Experimental analysis of materials in proton exchange membrane electrolysis cells

被引:10
作者
Ferriday, T. [1 ]
Middleton, P. H. [1 ]
机构
[1] Univ Agder, Kristiansand, Norway
关键词
PEM water electrolysis; AC impedance; Micro porous layer; Material stability; Low-cost design; IMPEDANCE; BATTERIES; HYDROGEN;
D O I
10.1016/j.ijhydene.2019.09.020
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An accelerated supply and demand of energy has resulted in an increased need for efficient energy storage options, where storing energy in hydrogen gas emerges as one of the most attractive. In this study, a singular proton exchange membrane (PEM) electrolysis cell was designed using adequately low-cost materials, and tested using polarisation curves, cyclic voltammetry and AC impedance. A comparative study of various micro porous layer (MPL) materials was performed in an effort to find suitable options which are able to steadily operate under anodic conditions. The best performance was achieved using carbon cloth, however this material was unstable. Untreated porous titanium and nickel displayed increased stability, though these materials require further development to match the initial performance of carbon cloth as an MPL material. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:27656 / 27663
页数:8
相关论文
共 17 条
[1]   AC IMPEDANCE OF COMPLEX ELECTROCHEMICAL REACTIONS [J].
ARMSTRONG, RD ;
FIRMAN, RE ;
THIRSK, HR .
FARADAY DISCUSSIONS, 1973, 56 :244-263
[2]   Dynamic modeling and simulation of a proton exchange membrane electrolyzer for hydrogen production [J].
Awasthi, A. ;
Scott, Keith ;
Basu, S. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (22) :14779-14786
[3]   Role of hydrogen in resolving electricity grid issues [J].
Bennoua, S. ;
Le Duigou, A. ;
Quemere, M. -M. ;
Dautremont, S. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (23) :7231-7245
[4]   A comprehensive review on PEM water electrolysis [J].
Carmo, Marcelo ;
Fritz, David L. ;
Merge, Juergen ;
Stolten, Detlef .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (12) :4901-4934
[5]  
Dagdougui H, 2018, HYDROGEN INFRASTRUCTURE FOR ENERGY APPLICATIONS: PRODUCTION, STORAGE, DISTRIBUTION AND SAFETY, P37, DOI 10.1016/B978-0-12-812036-1.00004-4
[6]   Non-linear impedance for a two-step electrode reaction with an intermediate adsorbed species [J].
Diard, JP ;
LeGorrec, B ;
Montella, C .
ELECTROCHIMICA ACTA, 1997, 42 (07) :1053-1072
[7]   High-pressure PEM water electrolysis and corresponding safety issues [J].
Grigoriev, S. A. ;
Porembskiy, V. I. ;
Korobtsev, S. V. ;
Fateev, V. N. ;
Aupretre, F. ;
Millet, P. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (03) :2721-2728
[9]   Semiempirical model for determining PEM electrolyzer stack characteristics [J].
Harrison, Kevin W. ;
Hernandez-Pacheco, Eduardo ;
Mann, Michael ;
Salehfar, Hossein .
JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2006, 3 (02) :220-223
[10]   Control and energy efficiency of PEM water electrolyzers in renewable energy systems [J].
Koponen, Joonas ;
Kosonen, Antti ;
Ruuskanen, Vesa ;
Huoman, Kimmo ;
Niemela, Markku ;
Ahola, Jero .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (50) :29648-29660