Increased Pacemaker Implantation Rate After New-Generation Balloon-Expandable SAPIEN 3 Valve Who Was to Blame, the Valve or the Doctor?

被引:3
作者
Barbanti, Marco [1 ]
机构
[1] Univ Catania, Ferrarotto Hosp, Div Cardiol, I-95100 Catania, Italy
关键词
aortic stenosis; conduction disturbances; TAVR; TRANSCATHETER AORTIC-VALVE;
D O I
10.1016/j.jcin.2016.02.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:814 / 816
页数:3
相关论文
共 8 条
[1]   Open issues in transcatheter aortic valve implantation. Part 2: procedural issues and outcomes after transcatheter aortic valve implantation [J].
Bax, Jeroen J. ;
Delgado, Victoria ;
Bapat, Vinayak ;
Baumgartner, Helmut ;
Collet, Jean P. ;
Erbel, Raimund ;
Hamm, Christian ;
Kappetein, Arie P. ;
Leipsic, Jonathon ;
Leon, Martin B. ;
MacCarthy, Philip ;
Piazza, Nicolo ;
Pibarot, Philippe ;
Roberts, William C. ;
Rodes-Cabau, Josep ;
Serruys, PatrickW. ;
Thomas, Martyn ;
Vahanian, Alec ;
Webb, John ;
Zamorano, Jose Luis ;
Windecker, Stephan .
EUROPEAN HEART JOURNAL, 2014, 35 (38) :2639-+
[2]   Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation The Critical Role of Valve Implantation Height [J].
De Torres-Alba, Fernando ;
Kaleschke, Gerrit ;
Diller, Gerhard Paul ;
Vormbrock, Julia ;
Orwat, Stefan ;
Radke, Robert ;
Reinke, Florian ;
Fischer, Dieter ;
Reinecke, Holger ;
Baumgartner, Helmut .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (08) :805-813
[3]  
Kodali S, 2015, ACC 2015 MARCH 15 16
[4]   Transcatheter Aortic Valve Implantation With the New Balloon-Expandable Sapien 3 Versus Sapien XT Valve System A Propensity Score-Matched Single-Center Comparison [J].
Nijhoff, Freek ;
Abawi, Masieh ;
Agostoni, Pierfrancesco ;
Ramjankhan, Faiz Z. ;
Doevendans, Pieter A. ;
Stella, Pieter R. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (06)
[5]   Anatomy of the Aortic Valvar Complex and Its Implications for Transcatheter Implantation of the Aortic Valve [J].
Piazza, Nicolo ;
de Jaegere, Peter ;
Schultz, Carl ;
Becker, Anton E. ;
Serruys, Patrick W. ;
Anderson, Robert H. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (01) :74-81
[6]   Predictors of Permanent Pacemaker Implantation in Patients With Severe Aortic Stenosis Undergoing TAVR A Meta-Analysis [J].
Siontis, George C. M. ;
Jueni, Peter ;
Pilgrim, Thomas ;
Stortecky, Stefan ;
Buellesfeld, Lutz ;
Meier, Bernhard ;
Wenaweser, Peter ;
Windecker, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (02) :129-140
[7]   Unravelling the (arte)fact of increased pacemaker rate with the Edwards SAPIEN 3 valve [J].
Tarantini, Giuseppe ;
Mojoli, Marco ;
Purita, Paola ;
Napodano, Massimo ;
D'Onofrio, Augusto ;
Frigo, Annachiara ;
Covolo, Elisa ;
Facchin, Michela ;
Isabella, Giambattista ;
Gerosa, Gino ;
Iliceto, Sabino .
EUROINTERVENTION, 2015, 11 (03) :343-350
[8]   Multicenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve [J].
Webb, John ;
Gerosa, Gino ;
Lefevre, Thierry ;
Leipsic, Jonathon ;
Spence, Mark ;
Thomas, Martyn ;
Thielmann, Matthias ;
Treede, Hendrik ;
Wendler, Olaf ;
Walther, Thomas .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (21) :2235-2243