Correction of heart motion due to respiration in clinical myocardial perfusion SPECT scans using respiratory gating

被引:80
作者
Kovalski, Gil
Israel, Ora
Keidar, Zohar
Frenkel, Alex
Sachs, Jonathan
Azhari, Haim
机构
[1] Technion Israel Inst Technol, Fac Biomed Engn, IL-30200 Haifa, Israel
[2] GE HealthCare, Haifa, Israel
[3] Dept Nucl Med, Haifa, Israel
[4] Technion Israel Inst Technol, Sch Med, Haifa, Israel
关键词
respiration; gating; list mode; motion;
D O I
10.2967/jnumed.106.037390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several studies have described nonuniform blurring of myocardial perfusion imaging (MPI) due to respiration. This article describes a technique for correcting the respiration effect and assesses its effectiveness in clinical studies. Methods: Simulated phantoms, physical phantoms, and patient scans were used in this study. A heart phantom, which oscillated back and forth, was used to simulate respiration. The motion was measured on a gamma-camera supporting list-mode functionality synchronized with an external respiratory strap or resistor sensor. Eight clinical scans were performed using a 1-d(99m)Tc-sestamibi protocol while recording the respiratory signal. The list-mode capability along with the strap or sensor signals was used to generate respiratory bin projection sets. A segmentation process was used to detect the shift between the respiratory bins. This shift was further projected to the acquired projection images for correction of the respiratory motion. The process was applied to the phantom and patient studies, and the rate of success of the correction was assessed using the conventional bull's eye maps. Results: The algorithm provided a good correction for the phantom studies. The shift after the correction, measured by a fitted ellipsoid, was < 1 mm in the axial direction. The average motion due to respiration in the clinical studies was 9.1 mm in the axial direction. The average shift between the respiratory phases was reduced to 0.5 mm after correction. The maximal change in the bull's eye map for the clinical scans after the correction was 6%, with a mean of 3.75%. The postcorrection clinical summed perfusion images were more uniform, consistent, and, for some patients, clinically significant when compared with the images before correction for respiration. Conclusion: Myocardial motion generated by respiration during MPI SPECT affects perfusion image quality and accuracy. Motion introduced by respiration can be corrected using the proposed method. The degree of correction depends on the patient respiratory pattern and can be of clinical significance in certain cases.
引用
收藏
页码:630 / 636
页数:7
相关论文
共 16 条
[1]   Predictive cardiac motion modeling and correction with partial least squares regression [J].
Ablitt, NA ;
Gao, JX ;
Keegan, J ;
Stegger, L ;
Firmin, DN ;
Yang, GZ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) :1315-1324
[2]   Correction of the respiratory motion of the heart by tracking of the center of mass of thresholded projections: A simulation study using the dynamic MCAT phantom [J].
Bruyant, PP ;
King, MA ;
Pretorius, PH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2159-2166
[3]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[4]   Development of respiratory gated myocardial SPECT system [J].
Cho, K ;
Kumiata, S ;
Okada, S ;
Kumazaki, T .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (01) :20-28
[5]  
Farkash G, 2006, J NUCL CARDIOL, V13, pS5
[6]   Real-time system for respiratory-cardiac gating in positron tomography [J].
Klein, GJ ;
Reutter, BW ;
Ho, MH ;
Reed, JH ;
Huesman, RH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2139-2143
[7]   Four-dimensional affine registration models for respiratory-gated PET [J].
Klein, GJ ;
Reutter, BW ;
Huesman, RH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :756-760
[8]   Respiratory gating of cardiac PET data in list-mode acquisition [J].
Livieratos, L ;
Rajappan, K ;
Stegger, L ;
Schafers, K ;
Bailey, DL ;
Camici, PG .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (05) :584-588
[9]   Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET [J].
Livieratos, L ;
Stegger, L ;
Bloomfield, PM ;
Schafers, K ;
Bailey, DL ;
Camici, PG .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (14) :3313-3322
[10]  
Pitman AG, 2002, J NUCL MED, V43, P1259